<br />1. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH TABLE 150.0-A.
<br />2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN
<br />EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR OR OCCUPANT SENSOR
<br />PROVIDED THE OCCUPANT SENSOR IS INITIALLY PROGRAMMED
<br />LIKE A VACANCY SENSOR (MANUAL-ON OPERATION). 150(K) 2I
<br />3. LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL THE FOLLOWING: LISTED FOR ZERO
<br />CLEARANCE INSULATION, LABELLED THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH A LEAKAGE
<br />LESS THAN 2.0CFM AT 75 PASCALS, SEALED WITH A GASKET OR
<br />CAULK, ALLOW REPLACEMENT AND MAINTENANCE TO BE READILY ACCESSIBLE FROM BELOW THE
<br />CEILING WITHOUT CUTTING HOLES IN THE CEILING, SHALL NOT CONTAIN SCREW BASE SOCKETS,
<br />AND SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH JA8.
<br />4. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH
<br />THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING: CONTROLLED BY PHOTOCELL
<br />AND MOTION SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH CONTROL, ASTRONOMICAL
<br />TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM. CBEES 150(K)3
<br />5. NO CONTROLS SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION WHERE THAT
<br />DIMMER OR VACANCY SENSOR HAS BEEN INSTALLED TO COMPLY WITH 150.0(K).
<br />1. ALL WORK SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE AND REGULATIONS OF GOVERNING
<br />AGENCIES AND SHALL COMPLY WITH THE REQUIREMENTS OF THE SERVING POWER AND TELEPHONE
<br />COMPANIES.
<br />2. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52.
<br />3. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC
<br />ARTICLE 210-70.
<br />4. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8
<br />5. ELECTRICAL SERVICE SIZE: 225 AMPS, MIN.
<br />6. GFCI OUTLETS ARE REQUIRED: FOR ALL KITCHEN RECEPTACLES THAT ARE DESIGNED TO SERVE
<br />COUNTERTOP SURFACES, DISHWASHERS, BATHROOMS, IN UNDER-FLOOR SPACES OR BELOW GRADE
<br />LEVEL, IN UNFINISHED BASEMENTS, CRAWL SPACE LIGHTING OUTLETS, IN EXTERIOR OUTLETS, WITHIN 6’
<br />OF A LAUNDRY/UTILITY/WET BAR SINK, LAUNDRY AREAS, AND IN ALL GARAGE OUTLETS INCLUDING
<br />OUTLETS DEDICATED TO A SINGLE DEVICE OR GARAGE DOOR OPENER. (CEC 210.8). KITCHEN AND
<br />LAUNDRY RECEPTACLE SHALL BE BOTH AFCI AND GFCI PROTECTED.
<br />7. OUTDOOR RECEPTACLES SHALL BE LOCATED PER CODE MINIMUM REQUIREMENTS, AND AFCI, GFCI, W.R.,
<br />AND W.P. WITH A BUBBLE COVER.
<br />8. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO
<br />REINFORCING BAR IN CONCRETE FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN.
<br />9. RECEPTACLES AND WALL SWITCHES SHALL BE INSTALLED NOT LESS THAN 15" MEASURED FROM
<br />BOTTOM OF IT TO FINISH FLOOR AND LOCATED NO MORE THAN AT 48" MEASURED FROM TOP OF
<br />RECEPTACLES AND WALL SWITCHES TO FINISH FLOOR IN VERTICAL DIRECTION, UNLESS OTHERWISE
<br />NOTED. ( CBC 1136 ).
<br />10. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED
<br />HORIZONTALLY BY 24". BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND
<br />BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE AND INTERCOM OUTLETS MUST BE
<br />INSTALLED IN BOXES ACCORDINGLY)
<br />11. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION
<br />12. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50%
<br />13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR
<br />OBSTRUCTION.
<br />14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO
<br />EXCEED 50 DBA (55 DBA WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION
<br />10.26.045 OF THE LOCATION OF MEASUREMENTS TO BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY
<br />LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY
<br />15. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO
<br />CONCRETE REPLACEMENT
<br />16. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED.
<br />17. PROVIDE RECEPTACLES AT 6' FROM CORNERS, 12' ON CENTER.
<br />18. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM.
<br />19. ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUIT IN KITCHEN, FAMILY ROOMS, DINING
<br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,
<br />CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECT BY A LISTED ARC-FAULT
<br />CIRCUIT INTERRUPTER (AFCI) COMBINATION TYPE (CEC210.12).
<br />20. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTES AND BE MICROWAVE /
<br />ULTRASONIC OR PASSIVE INFRA-RED TYPE.
<br />21. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO
<br />SLEEPING ROOMS, IN EACH SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE
<br />DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, OR WITHIN 3 FEET OF DOORS TO KITCHEN OR
<br />BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY BACK-UP. DETECTORS
<br />TO BE INTERCONNECTED TO SOUND AT THE SAME TIME.
<br />22. PROVIDE A MINIMUM OF 2 –20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTER TOPS.
<br />SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED .(210-52(B)(2)
<br />23. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHW ASHER, CLOTHES WASHER, DRYER, BUILT-
<br />IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A
<br />SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT
<br />24. ALL 15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPERRESISTANT RECEPTACLES ,ALL 15/20
<br />AMPERE RECEPTACLES IN WET LOCATIONS SHALL HAVE IN-USE (BUBBLE) COVERS INSTALLED. ALL
<br />RECEPTACLES IN WET LOCATIONS SHALL ALSO BE LISTED W EATHER-RESISTANT TYPE GFCI. (CEC 406.9(B)
<br />(1))
<br />25. ALL LIGHTS ARE HIGH EFFICACY
<br />26. ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1))
<br />27. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH
<br />EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY
<br />SENSOR.
<br />28. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO
<br />HAVE A ZERO CLEARANCE INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED
<br />WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING
<br />29. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT
<br />CANDLE (11 LUX).
<br />30. AT LEAST ONE LIGHTING SHALL BE INSTALLED IN THE ATTIC.
<br />31. A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER
<br />OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. 210-11(C)3)
<br />32. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR
<br />AREA WITHIN 6FT FROM EDGE OF THE SINKS (CEC 210-8)
<br />33. PROVIDE A MINIMUM OF 1 –20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER
<br />OUTLETS. (210.11(C)(2)
<br />34. IN THE KITCHEN AND DINING AREA, A RECEPTACLE SHALL BE PROVIDED FOR ISLAND COUNTERTOP
<br />SPACES WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES
<br />OR GREATER. (210-52(C)(2)
<br />35. AT LEAST ONE LIGHT OUTLET, CONTROLLED BY A WALL SWITCH, SHALL BE INSTALLED IN EVERY
<br />HABITABLE ROOM, BATH ROOM, HALLWAY, GARAGE AND AT EACH OUT DOOR ENTRANCE.
<br />36. GFCI AT ISLAND CANNOT HAVE MORE THAN 6 INCHES OVERHANG WHERE INSTALLED.
<br />37. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL
<br />ON/OFF SWITCH MOTION SENSOR WITHOUT OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION
<br />SENSOR AND:
<br />A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL
<br />B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES
<br />ASTRONOMICAL CLOCK
<br />C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT
<br />ALLOWS LUMINAIRES TO BE ALWAYS ON
<br />D. RATED FOR WET LOCATIONS
<br />38. THE MINIMUM SIZE GROUND WIRE SHALL BE #8 CU OR #6 AL.
<br />39. ALL SERVICES SHALL BE GROUNDED WITH A CONCRETE ENCASED ELECTRODE OR A GROUND ROD AND
<br />BONDED TO THE COLD WATER PIPE
<br />(N) DUAL-GANG ELECT. METER BOX
<br />(N) ADU ELECTRICAL SUB-PANEL 225 AMPS (PROVIDE MINIMUM 20 FEET UFER GROUND)
<br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS
<br />LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF)
<br />PHOTOCELL CONTROL / MOTION SENSOR
<br />1
<br />2
<br />3
<br />4
<br />5
<br />7
<br />(N) HEAT PUMP UNIT ON 3'' THIK.CONCRETE PAD6
<br />120-V WATERPROOF RECEPTACLE W/COVER8
<br />EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF)9
<br />10 EXHAUST FAN FOR BATHROOM SHALL BE MIN. 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH
<br />ROOF)
<br />(N) CONSUMER TANK WITH/ HEAT PUMP
<br />(N) 22X30 ATTIC ACCESS
<br />EXHAUST FAN ABOVE KITCHEN RANGE
<br />SHALL BE 85% CE OR 250 CFM (EXHAUST
<br />THROUGH ROOF)
<br />EXHAUST FAN SHALL BE ENERGY STAR RATED.
<br />CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN.
<br />INTERMITTENT W/ HUMIDITY CONTROL PER CMC
<br />402.5, BETWEEN 50%-80%
<br />SHALL BE DUCTED TO OUTSIDE THROUGH
<br />ROOF/EXTERIOR WALL
<br />IAQ FAN: ( MIN 46 CFM PER T-24 )
<br />PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM,
<br />MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE
<br />SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD
<br />CARBON MONOXIDE DETECTOR ALARM
<br />HARDWIRED w/ BATTERY BACK UPCD
<br />22X30 ATTIC ACCESS
<br />AIR HANDLERS
<br />HEATPUMP ON PAD 3" MIN.
<br />HEATPUMP WATER HEATER
<br />L.E.D. RECESSED LIGHT FIXTURE
<br />GF
<br />C
<br />I
<br />110V DUPLEX OUTLET, ARC
<br />FAULT CIRCUIT INTERRUPTER
<br />(ENTIRE CIRCUIT)
<br />AF
<br />C
<br />I
<br />CEILING AIR DIFFUSER
<br />110V DUPLEX OUTLET, GROUND
<br />FAULT CIRCUIT INTERRUPT
<br />(ENTIRE CIRCUIT)
<br />GARBAGE DISPOSAL
<br />SWITCH W/ MOTION SENSOR
<br />(VACANCY SENSOR)
<br />VS
<br />2-WAY SWITCH
<br />2D
<br />VANITY WALL LIGHT
<br />EXTERIOR WALL SCONCE
<br />LIGHT
<br />VS
<br />DIMMER SWITCH
<br />D
<br />ELECTRICAL
<br />PANEL/METER/INVERTER
<br />PER KEYNOTE
<br />MEDIA OUTLET
<br />P PHOTO CELL
<br />M
<br />J-BOX (CEILING FAN/LIGHT
<br />FIXTURE)
<br />DRYER EXHAUST
<br />W/P : WEATHER -RESISTANT
<br />W/R : WATER PROOF
<br />T THERMOSTAT WHOLE HOUSE FAN: 1186.5
<br />CFM PER T-24
<br />E ELECTRICAL VEHICLE CHARGING
<br />STATION LOCATION. 208/240-VOLT
<br />BRANCH CIRCUIT (40 AMP)
<br />1
<br />9F
<br />T
<br />
<br />C
<br />L
<br />'
<br />G
<br />SD
<br />CDSD
<br />CDSD
<br />SD
<br />30"
<br />3
<br />5
<br />10
<br />10
<br />6
<br />9
<br />G/
<br />A
<br />AFCI
<br />D
<br />AF
<br />C
<br />I
<br />P
<br />GFCI
<br />W/P,W/R
<br />12
<br />'
<br />'
<br />GF
<br />C
<br />I
<br />G/A
<br />G/A
<br />G/A
<br />GFCI
<br />12''
<br />GFCI
<br />60''
<br />FUTURE 240V -READY USE
<br />P
<br />AFCI
<br />AFCI
<br />2D
<br />AF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />AFCI
<br />AF
<br />C
<br />I
<br />P P
<br />D
<br />D
<br />P
<br />P D
<br />2D
<br />D
<br />VS
<br />VS
<br />VS
<br />9FT CL'G
<br />9FT CL'G
<br />9FT CL'G
<br />9FT CL'G
<br />9FT CL'G
<br />9FT CL'G
<br />VS
<br />GF
<br />C
<br />I
<br />GFCI
<br />22
<br />0
<br />V
<br />G/
<br />A
<br />,
<br />W
<br />/
<br />P
<br />22
<br />0
<br />V
<br />G/
<br />A
<br />,
<br />W
<br />/
<br />P
<br />D
<br />T
<br />T
<br />FUTURE 240V -READY USE
<br />2D
<br />AFCI
<br />AFCI
<br />2D
<br />36'' CLR.
<br />FRONT OF
<br />PANEL D
<br />W/P.W/R
<br />GFCI
<br />FUTURE 240V -READY USE
<br />2D
<br />2D
<br />2D
<br />GF
<br />C
<br />I
<br />E
<br />D
<br />GFCI
<br />GFCI
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />2D
<br />7 7
<br />77
<br />AFCI
<br />4
<br />7
<br />7
<br />9FT CL'G
<br />D
<br />12
<br />'
<br />'
<br />GF
<br />C
<br />I
<br />10 FT MIN.
<br />12
<br />'
<br />-
<br />1
<br />1
<br />"
<br />D
<br />ELECTRICAL VEHICLE
<br />CHARGING STATION
<br />LOCATION. 208/240-VOLT
<br />BRANCH CIRCUIT (40 AMP)
<br />1
<br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO
<br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY
<br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A
<br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND
<br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL
<br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE
<br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS
<br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR
<br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED.
<br />DESCRIPTIONDATEDELTA
<br />NEW DETACHED ADU 2
<br />BEDS, 2BATHS,
<br />LIVING , KITCHEN,
<br />DINING , GARAGE-1
<br />CAR
<br />PROJECT CONTACT
<br />OWNERSHIP
<br />KHANH DAO
<br />10448 SALINAS RIVER CIR
<br />FOUNTAIN VALLEY, CA 92708
<br />PHONE: (714) 390-5154
<br />28/11/2023 PLANNING CORRECTIONS
<br />LOAN PHAM
<br />17021 BOLERO LN
<br />HUNTINGTON BEACH, CA 92649
<br />PHONE: 714-614-6344
<br />EMAIL:
<br />LOANPHAM8888@YAHOO.COM
<br />1 02/22/2024 1ST PLAN CHECK
<br />A.07
<br />PROPOSED ADU
<br />ELECTRICAL PLAN
<br />(N
<br />)
<br />
<br />D
<br />E
<br />T
<br />A
<br />C
<br />H
<br />E
<br />D
<br />
<br />A
<br />D
<br />U
<br />,
<br />
<br />U
<br />N
<br />I
<br />T
<br />
<br />2
<br />90
<br />1
<br />
<br />E
<br />
<br />M
<br />Y
<br />R
<br />T
<br />L
<br />E
<br />
<br />S
<br />T
<br />,
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />(E
<br />)
<br />
<br />S
<br />I
<br />N
<br />G
<br />L
<br />E
<br />
<br />F
<br />A
<br />M
<br />I
<br />L
<br />Y
<br />
<br />R
<br />E
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />90
<br />1
<br />
<br />E
<br />
<br />M
<br />Y
<br />R
<br />T
<br />L
<br />E
<br />
<br />S
<br />T
<br />,
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />1
<br />ELECTRICAL NOTESELECTRICAL PLAN KEYNOTESCEILING/ELECTRICAL PLAN LEGEND
<br />1/4" = 1'-0"1PROPOSED ADU CEILING/LIGHTING & POWER PLAN
<br />LIGHTING REQUIREMENTS
<br />901 E Myrtle St Unit# 2 -
<br />1011181606/27/2024
|