Laserfiche WebLink
W/H <br />AT <br />T <br />I <br />C <br />HP <br />R <br />GD <br />J <br />RE <br />F <br />. <br />DW <br />DW <br />AT <br />T <br />I <br />C HP <br />R <br />R <br />R <br />R <br />R <br />R <br />R <br />R <br />R <br />R R <br />R <br />R <br />R <br />R <br />R <br />R <br />R <br />J <br />GD <br />1. ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. <br />2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN <br />EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR OR OCCUPANT SENSOR <br />PROVIDED THE OCCUPANT SENSOR IS INITIALLY PROGRAMMED <br />LIKE A VACANCY SENSOR (MANUAL-ON OPERATION). 150(K) 2I <br />3. LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL THE FOLLOWING: LISTED FOR ZERO <br />CLEARANCE INSULATION, LABELLED THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH A LEAKAGE <br />LESS THAN 2.0CFM AT 75 PASCALS, SEALED WITH A GASKET OR <br />CAULK, ALLOW REPLACEMENT AND MAINTENANCE TO BE READILY ACCESSIBLE FROM BELOW THE <br />CEILING WITHOUT CUTTING HOLES IN THE CEILING, SHALL NOT CONTAIN SCREW BASE SOCKETS, <br />AND SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH JA8. <br />4. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH <br />THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING: CONTROLLED BY PHOTOCELL <br />AND MOTION SENSOR, PHOTO CONTROL AND AUTOMATIC SWITCH CONTROL, ASTRONOMICAL <br />TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM. CBEES 150(K)3 <br />5. NO CONTROLS SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION WHERE THAT <br />DIMMER OR VACANCY SENSOR HAS BEEN INSTALLED TO COMPLY WITH 150.0(K). <br />1. ALL WORK SHALL BE IN FULL ACCORDANCE WITH ALL APPLICABLE AND REGULATIONS OF GOVERNING <br />AGENCIES AND SHALL COMPLY WITH THE REQUIREMENTS OF THE SERVING POWER AND TELEPHONE <br />COMPANIES. <br />2. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52. <br />3. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC <br />ARTICLE 210-70. <br />4. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8 <br />5. ELECTRICAL SERVICE SIZE: 225 AMPS, MIN. <br />6. GFCI OUTLETS ARE REQUIRED: FOR ALL KITCHEN RECEPTACLES THAT ARE DESIGNED TO SERVE <br />COUNTERTOP SURFACES, DISHWASHERS, BATHROOMS, IN UNDER-FLOOR SPACES OR BELOW GRADE <br />LEVEL, IN UNFINISHED BASEMENTS, CRAWL SPACE LIGHTING OUTLETS, IN EXTERIOR OUTLETS, WITHIN 6’ <br />OF A LAUNDRY/UTILITY/WET BAR SINK, LAUNDRY AREAS, AND IN ALL GARAGE OUTLETS INCLUDING <br />OUTLETS DEDICATED TO A SINGLE DEVICE OR GARAGE DOOR OPENER. (CEC 210.8). KITCHEN AND <br />LAUNDRY RECEPTACLE SHALL BE BOTH AFCI AND GFCI PROTECTED. <br />7. OUTDOOR RECEPTACLES SHALL BE LOCATED PER CODE MINIMUM REQUIREMENTS, AND AFCI, GFCI, W.R., <br />AND W.P. WITH A BUBBLE COVER. <br />8. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO <br />REINFORCING BAR IN CONCRETE FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN. <br />9. RECEPTACLES AND WALL SWITCHES SHALL BE INSTALLED NOT LESS THAN 15" MEASURED FROM <br />BOTTOM OF IT TO FINISH FLOOR AND LOCATED NO MORE THAN AT 48" MEASURED FROM TOP OF <br />RECEPTACLES AND WALL SWITCHES TO FINISH FLOOR IN VERTICAL DIRECTION, UNLESS OTHERWISE <br />NOTED. ( CBC 1136 ). <br />10. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED <br />HORIZONTALLY BY 24". BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND <br />BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE AND INTERCOM OUTLETS MUST BE <br />INSTALLED IN BOXES ACCORDINGLY) <br />11. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION <br />12. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50% <br />13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR <br />OBSTRUCTION. <br />14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO <br />EXCEED 50 DBA (55 DBA WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION <br />10.26.045 OF THE LOCATION OF MEASUREMENTS TO BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY <br />LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY <br />15. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO <br />CONCRETE REPLACEMENT <br />16. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED. <br />17. PROVIDE RECEPTACLES AT 6' FROM CORNERS, 12' ON CENTER. <br />18. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM. <br />19. ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUIT IN KITCHEN, FAMILY ROOMS, DINING <br />ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, <br />CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECT BY A LISTED ARC-FAULT <br />CIRCUIT INTERRUPTER (AFCI) COMBINATION TYPE (CEC210.12). <br />20. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTES AND BE MICROWAVE / <br />ULTRASONIC OR PASSIVE INFRA-RED TYPE. <br />21. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO <br />SLEEPING ROOMS, IN EACH SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE <br />DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, OR WITHIN 3 FEET OF DOORS TO KITCHEN OR <br />BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY BACK-UP. DETECTORS <br />TO BE INTERCONNECTED TO SOUND AT THE SAME TIME. <br />22. PROVIDE A MINIMUM OF 2 –20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTER TOPS. <br />SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED .(210-52(B)(2) <br />23. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHW ASHER, CLOTHES WASHER, DRYER, BUILT- <br />IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A <br />SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT <br />24. ALL 15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPERRESISTANT RECEPTACLES ,ALL 15/20 <br />AMPERE RECEPTACLES IN WET LOCATIONS SHALL HAVE IN-USE (BUBBLE) COVERS INSTALLED. ALL <br />RECEPTACLES IN WET LOCATIONS SHALL ALSO BE LISTED W EATHER-RESISTANT TYPE GFCI. (CEC 406.9(B) <br />(1)) <br />25. ALL LIGHTS ARE HIGH EFFICACY <br />26. ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)) <br />27. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH <br />EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY <br />SENSOR. <br />28. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO <br />HAVE A ZERO CLEARANCE INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED <br />WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING <br />29. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT <br />CANDLE (11 LUX). <br />30. AT LEAST ONE LIGHTING SHALL BE INSTALLED IN THE ATTIC. <br />31. A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. 210-11(C)3) <br />32. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR <br />AREA WITHIN 6FT FROM EDGE OF THE SINKS (CEC 210-8) <br />33. PROVIDE A MINIMUM OF 1 –20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS. (210.11(C)(2) <br />34. IN THE KITCHEN AND DINING AREA, A RECEPTACLE SHALL BE PROVIDED FOR ISLAND COUNTERTOP <br />SPACES WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES <br />OR GREATER. (210-52(C)(2) <br />35. AT LEAST ONE LIGHT OUTLET, CONTROLLED BY A WALL SWITCH, SHALL BE INSTALLED IN EVERY <br />HABITABLE ROOM, BATH ROOM, HALLWAY, GARAGE AND AT EACH OUT DOOR ENTRANCE. <br />36. GFCI AT ISLAND CANNOT HAVE MORE THAN 6 INCHES OVERHANG WHERE INSTALLED. <br />37. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL <br />ON/OFF SWITCH MOTION SENSOR WITHOUT OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION <br />SENSOR AND: <br />A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL <br />B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES <br />ASTRONOMICAL CLOCK <br />C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT <br />ALLOWS LUMINAIRES TO BE ALWAYS ON <br />D. RATED FOR WET LOCATIONS <br />38. THE MINIMUM SIZE GROUND WIRE SHALL BE #8 CU OR #6 AL. <br />39. ALL SERVICES SHALL BE GROUNDED WITH A CONCRETE ENCASED ELECTRODE OR A GROUND ROD AND <br />BONDED TO THE COLD WATER PIPE <br />(N) DUAL-GANG ELECT. METER BOX <br />(N) ADU ELECTRICAL SUB-PANEL 225 AMPS (PROVIDE MINIMUM 20 FEET UFER GROUND) <br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS <br />LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL/ROOF) <br />PHOTOCELL CONTROL / MOTION SENSOR <br />1 <br />2 <br />3 <br />4 <br />5 <br />7 <br />(N) HEAT PUMP UNIT ON 3'' THIK.CONCRETE PAD6 <br />120-V WATERPROOF RECEPTACLE W/COVER8 <br />EXHAUST FAN ABOVE KITCHEN RANGE SHALL BE 85% CE OR 250 CFM (EXHAUST THROUGH ROOF)9 <br />10 EXHAUST FAN FOR BATHROOM SHALL BE MIN. 50 CFM AND CONTAIN HUMIDISTAT (EXHAUST THROUGH <br />ROOF) <br />(N) CONSUMER TANK WITH/ HEAT PUMP <br />(N) 22X30 ATTIC ACCESS <br />EXHAUST FAN ABOVE KITCHEN RANGE <br />SHALL BE 85% CE OR 250 CFM (EXHAUST <br />THROUGH ROOF) <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. <br />CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. <br />INTERMITTENT W/ HUMIDITY CONTROL PER CMC <br />402.5, BETWEEN 50%-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH <br />ROOF/EXTERIOR WALL <br />IAQ FAN: ( MIN 46 CFM PER T-24 ) <br />PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, <br />MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE <br />SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UPSD <br />CARBON MONOXIDE DETECTOR ALARM <br />HARDWIRED w/ BATTERY BACK UPCD <br />22X30 ATTIC ACCESS <br />AIR HANDLERS <br />HEATPUMP ON PAD 3" MIN. <br />HEATPUMP WATER HEATER <br />L.E.D. RECESSED LIGHT FIXTURE <br />GF <br />C <br />I <br />110V DUPLEX OUTLET, ARC <br />FAULT CIRCUIT INTERRUPTER <br />(ENTIRE CIRCUIT) <br />AF <br />C <br />I <br />CEILING AIR DIFFUSER <br />110V DUPLEX OUTLET, GROUND <br />FAULT CIRCUIT INTERRUPT <br />(ENTIRE CIRCUIT) <br />GARBAGE DISPOSAL <br />SWITCH W/ MOTION SENSOR <br />(VACANCY SENSOR) <br />VS <br />2-WAY SWITCH <br />2D <br />VANITY WALL LIGHT <br />EXTERIOR WALL SCONCE <br />LIGHT <br />VS <br />DIMMER SWITCH <br />D <br />ELECTRICAL <br />PANEL/METER/INVERTER <br />PER KEYNOTE <br />MEDIA OUTLET <br />P PHOTO CELL <br />M <br />J-BOX (CEILING FAN/LIGHT <br />FIXTURE) <br />DRYER EXHAUST <br />W/P : WEATHER -RESISTANT <br />W/R : WATER PROOF <br />T THERMOSTAT WHOLE HOUSE FAN: 1186.5 <br />CFM PER T-24 <br />E ELECTRICAL VEHICLE CHARGING <br />STATION LOCATION. 208/240-VOLT <br />BRANCH CIRCUIT (40 AMP) <br />1 <br />9F <br />T <br /> <br />C <br />L <br />' <br />G <br />SD <br />CDSD <br />CDSD <br />SD <br />30" <br />3 <br />5 <br />10 <br />10 <br />6 <br />9 <br />G/ <br />A <br />AFCI <br />D <br />AF <br />C <br />I <br />P <br />GFCI <br />W/P,W/R <br />12 <br />' <br />' <br />GF <br />C <br />I <br />G/A <br />G/A <br />G/A <br />GFCI <br />12'' <br />GFCI <br />60'' <br />FUTURE 240V -READY USE <br />P <br />AFCI <br />AFCI <br />2D <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />P P <br />D <br />D <br />P <br />P D <br />2D <br />D <br />VS <br />VS <br />VS <br />9FT CL'G <br />9FT CL'G <br />9FT CL'G <br />9FT CL'G <br />9FT CL'G <br />9FT CL'G <br />VS <br />GF <br />C <br />I <br />GFCI <br />22 <br />0 <br />V <br />G/ <br />A <br />, <br />W <br />/ <br />P <br />22 <br />0 <br />V <br />G/ <br />A <br />, <br />W <br />/ <br />P <br />D <br />T <br />T <br />FUTURE 240V -READY USE <br />2D <br />AFCI <br />AFCI <br />2D <br />36'' CLR. <br />FRONT OF <br />PANEL D <br />W/P.W/R <br />GFCI <br />FUTURE 240V -READY USE <br />2D <br />2D <br />2D <br />GF <br />C <br />I <br />E <br />D <br />GFCI <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />AF <br />C <br />I <br />2D <br />7 7 <br />77 <br />AFCI <br />4 <br />7 <br />7 <br />9FT CL'G <br />D <br />12 <br />' <br />' <br />GF <br />C <br />I <br />10 FT MIN. <br />12 <br />' <br />- <br />1 <br />1 <br />" <br />D <br />ELECTRICAL VEHICLE <br />CHARGING STATION <br />LOCATION. 208/240-VOLT <br />BRANCH CIRCUIT (40 AMP) <br />1 <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO <br />NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY <br />PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A <br />SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND <br />METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE <br />RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS <br />BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR <br />ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />NEW DETACHED ADU 2 <br />BEDS, 2BATHS, <br />LIVING , KITCHEN, <br />DINING , GARAGE-1 <br />CAR <br />PROJECT CONTACT <br />OWNERSHIP <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />28/11/2023 PLANNING CORRECTIONS <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: <br />LOANPHAM8888@YAHOO.COM <br />1 02/22/2024 1ST PLAN CHECK <br />A.07 <br />PROPOSED ADU <br />ELECTRICAL PLAN <br />(N <br />) <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />(E <br />) <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />90 <br />1 <br /> <br />E <br /> <br />M <br />Y <br />R <br />T <br />L <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />ELECTRICAL NOTESELECTRICAL PLAN KEYNOTESCEILING/ELECTRICAL PLAN LEGEND <br />1/4" = 1'-0"1PROPOSED ADU CEILING/LIGHTING & POWER PLAN <br />LIGHTING REQUIREMENTS <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024