Laserfiche WebLink
SW_LINE 3 1st Floor Passe d <br />Exterior Wall Drection Y Location:(40.10, 8.33) <br />Loads <br />SECTION D1Y_ROOF: W=330 LB, E=276 LB (10ft) <br />Wall Self-Weight Seismic = 139 LB <br /> Strap <br />She arwall De sign USE TYPE: SW1 <br />Total Length (ft): 11.00 Total panel Length (ft): 8.00 ρ = 1.3 <br />Pane l Width (ft)Ne t <br />He ight (ft)H/W Actual (plf)Allowable <br />(plf) <br />Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic <br />A 8.00 10.00 1.25 41 62 260 364 260 SW1 <br />Ov e rturning Force s <br />Pane l Le ft Force s (lb)Right Force s (lb) <br />Dup Ddown L Lr S W E Dup Ddown L Lr S W E <br />A 680 226 0 0 0 429 496 680 226 0 0 0 429 496 <br />Holdown & De fle ction Che ck <br />Pane l Width (ft) <br />Ne t <br />He ight <br />(ft) <br />Le ft <br />Ratio <br />Right <br />Ratio <br />Pane l <br />De fle ction (in) <br />Uplift <br />(LB) <br />Down <br />(LB)Holdown/Post Uplift <br />(LB) <br />Down <br />(LB)Holddown/Post Actual Allowable <br />A 8.00 10.00 335 904 HDU2/4X4 0.11/0.12 335 904 HDU2/4X4 0.11/0.12 0.353 2.400 <br />vG23.06.30 <br />: <br />: <br />: <br />: <br />Com pany <br />Project (N) DETACHED ADU, UNIT 2 <br />Job No.231014 <br />Plan <br />: <br />: <br />: <br />: <br />Designed T.M. <br />Checked P.P. <br />Date 2023-12-26 <br />Client N/A <br />TIC Structure Design 2023 <br />23 <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024