Laserfiche WebLink
CA License #: 1003498 <br />Classification: B, C10, C46 <br />Namaste Solar Electric <br />888 Federal Boulevard <br />Denver, CO 80204 <br />Designer: <br />Owner: <br />Sunnova Energy Corporation <br />6531 Irvine Center Dr. #200 <br />Irvine, CA 92618 <br />DESIGNER INFORMATION <br />ORIGINAL BY:DATE: <br />REVIEWED BY:DATE: <br />REV. #BY DATE DESCRIPTION <br />DWG TITLE:PAGE #SCALE: <br />INDIVIDUAL PLOT PLAN NTSSPEC PAGE <br />COMMUNITY NAME <br />SANTA ANA 7 <br />BUILDER ADDRESS <br />SITE ADDRESS <br />SANTA ANA, CA 92704 <br />6531 IRVINE CENTER DR. #200 <br />IRVINE, CA 92618 <br />CITY VENTURES: <br />INSTALLATION NOTES: <br />SOLAR CONTRACTOR - <br />1.ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48" O.C. <br />2.ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS, TO MAXIMUM EXTENT POSSIBLE. <br />3.ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. <br />4.ROOFTOP WIRE TRANSITION WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. <br />5.PV ARRAY WILL BE A MINIMUM OF 3" ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. <br />6.THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE MANUFACTURER'S MANUAL AND INSTALLATION GUIDES. <br />7.MID CLAMPS REQUIRE .37 INCH (3/8") SPACE BETWEEN PV MODULES. RAILS SHALL EXTEND 2" BEYOND ARRAY. SOLAR CONTRACTOR IS RESPONSIBLE FOR PROPER RAIL LENGTH <br />AND INSTALLATION. <br />8.THE MAXIMUM HEIGHT OF A SOLAR COLLECTOR SHALL BE NO MORE THAN TWO FEET, MEASURED PERPENDICULAR TO THE ROOF SURFACE, AND MY NOT EXCEED THE MAXIMUM <br />OVERALL BUILDING HEIGHT. <br />9.ALL SOLAR ENERGY SYSTEM APPURTENANCES SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE WITHOUT COMPROMISING THE EFFECTIVENESS OF THE SOLAR <br />COLLECTORS, AND SHALL BE OF A COLOR SIMILAR TO THE COLOR OF THE SURFACE UPON WITH THEY ARE MOUNTED. <br />10.THE ADDRESS OF EACH UNIT SHALL BE VISIBLE ON THE SITE PLAN.   <br />11.RAIL/RACKING/MOUNTING SYSTEM HAS BEEN TESTED BASED ON UL 2703 AND CLASSIFIED AS CLASS A FIRE RATED COMPONENTS. (SEE MASTER PERMIT SET AND PROVIDED <br />SPEC SHEETS) <br />10.PV PANEL HAS BEEN TESTED BASED ON UL 1703. (SEE MASTER PERMIT SET AND PROVIDED SPEC SHEETS) <br />11.WHERE PV DISCONNECTING MEANS (ABOVE 30 VOLTS) ARE READILY ACCESSIBLE TO UNQUALIFIED PERSONS, ANY ENCLOSURE DOOR OR HINGED COVER THAT EXPOSES LIVE <br />PARTS WHEN OPENED, IS NOW REQUIRED TO BE LOCKED OR REQUIRE A TOOL TO OPEN PER CEC 690.13(A).  <br />STRUC 1 <br />CA License #: 1003498 <br />Classification: B, C10, C46 <br />Namaste Solar Electric <br />888 Federal Boulevard <br />Denver, CO 80204 <br />Designer: <br />Owner: <br />Sunnova Energy Corporation <br />6531 Irvine Center Dr. #200 <br />Irvine, CA 92618 <br />DESIGNER INFORMATION <br />ORIGINAL BY:DATE: <br />REVIEWED BY:DATE: <br />REV. #BY DATE DESCRIPTION <br />DWG TITLE:PAGE #SCALE <br />INDIVIDUAL PLOT PLAN <br />SANTA ANA 7 <br />BUILDER ADDRESS <br />SITE ADDRESS <br />SANTA ANA, CA 92704 <br />6531 IRVINE CENTER DR. #200 <br />IRVINE, CA 92618 <br />CITY VENTURES: <br />INSTALLATION NOTES: <br />SOLAR CONTRACTOR - <br />1.ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48" O.C. <br />2.ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS, TO MAXIMUM EXTENT POSSIBLE. <br />3.ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. <br />4.ROOFTOP WIRE TRANSITION WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. <br />5.PV ARRAY WILL BE A MINIMUM OF 3" ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. <br />6.THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE MANUFACTURER'S MANUAL AND INSTALLATION GUIDES. <br />7.MID CLAMPS REQUIRE .37 INCH (3/8") SPACE BETWEEN PV MODULES. RAILS SHALL EXTEND 2" BEYOND ARRAY. SOLAR CONTRACTOR IS RESPONSIBLE FOR PROPER RAIL LENGTH <br />AND INSTALLATION. <br />8.THE MAXIMUM HEIGHT OF A SOLAR COLLECTOR SHALL BE NO MORE THAN TWO FEET, MEASURED PERPENDICULAR TO THE ROOF SURFACE, AND MY NOT EXCEED THE MAXIMUM <br />OVERALL BUILDING HEIGHT. <br />9.ALL SOLAR ENERGY SYSTEM APPURTENANCES SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE WITHOUT COMPROMISING THE EFFECTIVENESS OF THE SOLAR <br />COLLECTORS, AND SHALL BE OF A COLOR SIMILAR TO THE COLOR OF THE SURFACE UPON WITH THEY ARE MOUNTED. <br />10.THE ADDRESS OF EACH UNIT SHALL BE VISIBLE ON THE SITE PLAN.   <br />11.RAIL/RACKING/MOUNTING SYSTEM HAS BEEN TESTED BASED ON UL 2703 AND CLASSIFIED AS CLASS A FIRE RATED COMPONENTS. (SEE MASTER PERMIT SET AND PROVIDED <br />SPEC SHEETS) <br />10.PV PANEL HAS BEEN TESTED BASED ON UL 1703. (SEE MASTER PERMIT SET AND PROVIDED SPEC SHEETS) <br />11.WHERE PV DISCONNECTING MEANS (ABOVE 30 VOLTS) ARE READILY ACCESSIBLE TO UNQUALIFIED PERSONS, ANY ENCLOSURE DOOR OR HINGED COVER THAT EXPOSES LIVE <br />PARTS WHEN OPENED, IS NOW REQUIRED TO BE LOCKED OR REQUIRE A TOOL TO OPEN PER CEC 690.13(A).  <br />STRUC 1 <br />PV MODULE (TYP.) <br />TPO ROOF, <br />INSTALLED BY OTHERS <br />IRONRIDGE RAIL <br />LOCATED UNDER PV ARRAY, (TYP.) <br />2 ARRAY PROFILE <br />1" = 1'-0" <br />PV MODULE <br />2PV-S1 <br />3 <br />PV-S1 <br />5 <br />PV-E2 <br />TPO ROOF, <br />INSTALLED BY OTHERS <br />IRONRIDGE TILT RACK ASSEMBLY <br />LOCATED UNDER PV ARRAY, (TYP.) <br />NEMA 3 TRANSITION BOX <br />LOCATED UNDER PV ARRAY, (TYP.) <br />RACKING EQUIPMENT SCHEDULE <br />VENDOR PART DESCRIPTION <br />PRO SOLAR FAST JACK E SERIES ATTACHMENT <br />IRONRIDGE FIXED TILT LEG KIT <br />IRONRIDGE XR10 RAILS - BLACK <br />IRONRIDGE CAMO END CLAMPS, CAMO-01-M1 (BLACK) <br />IRONRIDGE UFO MID CLAMPS <br />IRONRIDGE RAIL CAPS - BLACK <br />HARDWARE 516" x 3" LAG BOLT, SS <br />HARDWARE FENDER WASHER, 516", CLEAR, SS <br />4 IRONRIDGE ASSEMBLY - ROOF CONNECTION <br />6" = 1'-0" <br />3 IRONRIDGE ASSEMBLY ON ROOF - RAIL CONNECTION <br />6" = 1'-0" <br />1 FLAT ROOF LAYOUT - TYPICAL <br />3/4" = 1'-0" <br />IRONRIDGE RAIL <br />POST STANDOFF <br />4 <br />PV-S1 <br />3 <br />PV-S1 <br />TPO ROOF, INSTALLED BY OTHERS <br />POST STANDOFF <br />PV MODULE <br />IRONRIDGE RAIL <br />POST STANDOFF <br />5 IRONRIDGE CLAMP DETAILS <br />NTS <br />A <br />PV-S1 <br />B <br />PV-S1 <br />5B DETAIL - MID CLAMP PLAN <br />2" = 1'-0" <br />DETAIL - MID CLAMP FRONT <br />5A DETAIL - END CLAMP PLAN <br />2" = 1'-0" <br />DETAIL - END CLAMP FRONT <br />PV MODULE FRAME <br />UFO MID CLAMP <br />PV MODULE FRAME <br />UFO MID CLAMP <br />IRONRIDGE RAIL <br />PV MODULE FRAME <br />CAMO END CLAMP <br />IRONRIDGE RAIL <br />CAMO END CLAMP <br />PV MODULE FRAME <br />IRONRIDGE RAIL <br />PV MODULE FRAME (BELOW) <br />ANCHORS TO BE INSTALLED <br />IN ROOF FRAMING - <br />2.14 INCHES MINIMUM <br />EMBEDMENT <br />1' <br />- <br />0 <br />58" <br />2'-61516" <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />10.09.2023 <br />824 S Harbor Blvd <br />11/15/2023