Laserfiche WebLink
PAGE <br />REV: A3 10/29/2024 <br />MARIA VALADEZ <br />5313 W HENDERSON PL, SANTA  <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br />  109R-313VALA <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. (714) 493-3532 <br />APN: 108-392-16 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />PV-5.0 <br />#ESTAMP <br />ENERGY STORAGE SYSTEM  <br />DISCONNECT <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM DISCONNECT <br />PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) <br />WARNING! <br />DO NOT RELOCATE THIS  <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS  <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2),  <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS:  <br /> SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022  <br />ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY  <br />SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. <br /> SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING  <br />EFFECTIVE WORDS, COLORS AND SYMBOLS. <br /> LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR  <br />WIRING METHOD AND SHALL NOT BE HAND WRITTEN. <br /> LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE  <br />ENVIRONMENT INVOLVED. <br /> SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT  <br />SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br /> DO NOT COVER EXISTING MANUFACTURER LABELS. <br />SOLAR PV SYSTEM EQUIPPED  <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC  <br />PV PANELS <br />TURN RAPID SHUTDOWN  <br />SWITCH TO THE "OFF"  <br />POSITION TO SHUT DOWN  <br />PV SYSTEM AND REDUCE  <br />SHOCK HAZARD IN THE  <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD  <br />SIDES MAY BE ENERGIZED IN  <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S),  AC/DC DISCONNECT(S),  <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC  <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING: PHOTOVOLTAIC  <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC  <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  <br />AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  <br />690.31(D)(2)CAUTION  <br />5313 W HENDERSON PL, SANTA ANA, CA, 92704 <br />SOLAR PANELS ON ROOF <br />PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 <br />MULTIPLE SOURCES OF POWER <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN  <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />RAPID SHUTDOWN SWITCH  <br />FOR SOLAR PV SYSTEM <br />WARNING! <br />SOURCES: UTILITY GRID,  <br />BATTERY AND PV SOLAR  <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN  <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC  <br />2022: 705.12(C) <br />ENERGY STORAGE SYSTEM <br />PREMISES WIRING MAY REMAIN  <br />ENERGIZED AFTER LOSS OF  <br />UTILITY POWER <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />AC DISCONNECT <br />INVERTER & ENERGY STORAGE  <br />(EXT) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />          48 AMPS <br />  240     VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />          48 AMPS <br />  240     VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />INVERTER 2 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />BACKUP GATEWAY <br />GENERATION AND BACKUP LOADS PANEL  <br />SERVICE ENTRANCE AND  <br />GATEWAY FEEDER BREAKER  <br />RAPID SHUTDOWN SWITCH <br />5313 W Henderson <br />Pl2/5/2025