Laserfiche WebLink
REVISION DESCRIPTION <br />GRID ALTERNATIVES GREATER LOS ANGELES <br />1662 LONG BEACH AVE, LOS ANGELES, CA 90021 <br />310-735-9762 (P) | 310-388-0288 (F) <br />CLC C-10, C-46 #867533 <br />DESIGNED BY <br />A. HU <br />07/31/2023 <br />PROJECT INFORMATION <br />CLIENT: HABITAT FOR HUMANITY ORANGE COUNTY <br />ADDRESS: 826 LACY ST, SANTA ANA, CA 92701 <br />APN: 398-041-18 <br />VALUATION: $10,000 <br />LEGEND <br />ARRAY KEY <br />ARRAY - #AZIMUTH PITCH <br />01 243°10:12 (39°) <br />02 63°10:12 (39°) <br />ARRAY COVERAGE <br />ARRAYS COVER APPROXIMATELY 27% OF AVAILABLE <br />ROOF SPACE. <br />NOTES <br />LADDER ACCESS POINT <br />1. ROOF ACCESS AND PATHWAYS ON DETACHED GARAGE <br />ARE EXEMPT PER CFC 1205.2 & CRC R324.6 EXCEPTION 1. <br />2. LADDER ACCESS POINTS SHALL BE LOCATED AT <br />UNOBSTRUCTED, STRONG POINTS OF BUILDING <br />CONSTRUCTION. <br />3. WORKSPACE CLEARANCE AROUND ALL ELECTRICAL <br />EQUIPMENT SHALL BE AT LEAST 30" WIDE AND 36" IN <br />FRONT OF EQUIPMENT (NEC 110.26) <br />4. ALL PV ELECTRICAL EQUIPMENT SHALL BE INSTALLED <br />AT LEAST 36" AWAY FROM ANY EXISTING GAS RISER. <br />5. CONDUIT SHALL RUN UNDER ROOF EAVE. 1/2" EMT <br />FLUSH-MOUNTED 1" OR GREATER ABOVE ROOFTOP. <br />6. CONDUIT SHALL BE HIDDEN AND PAINTED TO MATCH <br />WITH BUILDING WALL. <br />7. SYSTEM SHALL COMPLY WITH CEC 690.12 <br />REQUIREMENT FOR RAPID SHUTDOWN.SITE PLAN <br />SCALE: 1/16" = 1' <br />N <br />PV-2 <br />SITE PLAN <br />PROPERTY LINES <br />21' 1" <br />6' 7" <br />8' 7" <br />150' 3" <br />50' <br />(N) ARRAY - 01 <br />(N) ARRAY - 02 <br />(E) MAIN SERVICE PANEL <br />(N) AC COMBINER BOX <br />(N) AC DISCONNECT <br />(STACKED) <br />21' <br />6' 9" <br />37' 8" <br />FIRE SETBACKS EXCEPTION <br />CFC 1205.2 & CRC R324.6 <br />22' <br />LA <br />C <br />Y <br /> <br />S <br />T <br />DETACHED GARAGE <br />DRIVEWAY <br />SFD <br />AL <br />L <br />E <br />Y <br />2.600 kW DC / 2.314 kW CEC-AC <br />SOLAR ELECTRIC SYSTEM <br />MODULE <br />MICROINVERTER <br />COMBINER BOX (1) ENPHASE ENERGY <br />X2-IQ-AM1-240-4C WITH IQ GATEWAY <br />(8) ENPHASE ENERGY <br />IQ8PLUS-72-2-US (240V) <br />(8) JINKO SOLAR <br />JKM325PP-72 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2023-4435 Structural Only <br />August 8, 2023 <br />NOTE: <br />Engineer of Record assumes that all structural components of the existing <br />building were permitted and met the requirements of the Building Code at <br />the time of construction. Solar Contractor shall field verify that the roof <br />framing is in its existing permitted condition and capable of supporting <br />required live loads. Framing specified on solar plans shall be assumed to be <br />minimum size and spacing, actual framing may be different. <br />826 N Lacy St <br />08/30/23