STRING 1: (9x) CANADIAN SOLAR <br />CS3N-390MS [BLK] PV MODULES <br />WITH 9 S440 SE POWER OPTIMIZERS <br />STRING 2: (8x) CANADIAN SOLAR <br />CS3N-390MS [BLK] PV MODULES <br />WITH 8 S440 SE POWER OPTIMIZERS <br />1 <br />1 <br />JUNCTION BOX <br />- NEMA 3R <br />AS REQUIRED <br />2 <br />3+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />+ - <br />821 <br />921 <br />(N) INVERTER <br />SOLAREDGE SE6000H-US <br />(ENERGY HUB) RGM <br />DC AC <br />(1) (N) <br />SOLAREDGE <br />ENERGY BANK <br />BAT-10K1P <br />5.0kW, 9.7kWh <br />4 <br />MAIN (N) 200A <br />(N) 40A <br />M <br />BI-DIRECTIONAL <br />UTILITY METER <br />1PH/240V <br />MAIN BONDING JUMPER <br />TO UTILITY GRID <br />(OVERHEAD) <br />SOLAR BREAKER LOCATED <br />AT THE FURTHEST END OF <br />BUS BAR FROM THE MAIN <br />BREAKER <br />MAX BREAKER CALC.: <br />225A X 1.2 - 200A = 70A <br />(N) 225A/200A MAIN <br />SERVICE PANEL <br />240/120v 1-PH, 3-W <br />POINT OF INTERCONNECTION <br />LOAD SIDE 705.12(B)(3)(2) <br />(E) GROUNDING <br />ELECTRODE <br />(COPPER) <br />GROUND <br />ROD <br />METER NUMBER: 322010-086448 <br />CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br />ID CONDUCTOR (CU) CONDUIT CONDUCTORS IN CONDUIT EGC TEMP. CORR. FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING <br />2 3/4" EMT 4 & (1)G #8 0.91 15 18.75 40 36.4 90#10 THWN-2, in conduit <br />1 #10 PV Wire, in open air N/A N/A #6 0.91 15 18.75 40 36.4 90 <br />#8 THWN-2, in conduit 3/4" EMT #8 0.91 32 40 55 50.05 903 & (1)G <br />#10 THWN-2, in conduit 3/4" EMT #8 0.91 21 26 40 36.4 903 & (1)G4 <br />3 <br />DESIGN TEMPERATURES <br />ASHRAE 2% HIGH <br />30°C <br />2°C <br />ASHRAE EXTREME LOW <br />INVERTER 1 SPECS <br />SE6000H-US (ENERGY HUB)_RGM <br />AC VOLTAGE <br />240V <br />GROUND <br /> <br />MAX OCPD <br />35A <br />RATED POWER <br />6000W <br />MAX OUTPUT <br />25A <br />MAX INPUT <br />17A <br />MAX INPUT <br />480V <br />EFFICIENCY <br /> CEC <br />POWERBOX MAX OUTPUT CURRENT <br />OPTIMIZERS IN SERIES <br />NOMINAL STRING VOLTAGE <br />ARRAY OPERATING CURRENT <br />STRING DETAILS <br />STRING CALCULATIONS - INVERTER 1 <br />STRING 1 STRING 2 <br />15A <br />9 <br />380V <br />25A <br />15A <br />8 <br />380V <br />25A <br />TOTAL SYSTEM SUMMARY <br />ARRAY STC POWER <br />6630W <br />ARRAY PTC POWER <br />6193.1W <br />MAX AC CURRENT <br />25A <br />MAX AC POWER <br />6000W <br />MODULE SPECS <br />CANADIAN SOLAR <br />CS3N-390MS [BLK] <br />PMAX <br />390W <br />PTC <br />364.3W <br />ISC <br />11.38A <br />IMP <br />10.6A <br />VOC <br />44.1V <br />VMP <br />36.8V <br />TEMP. COEFF. OF VOC <br />-0.122 <br />POWER <br />OPTIMIZERS <br />RATED INPUT <br />MAX ISC <br />WEIGHTED EFFICIENCY <br />MAX OUTPUT <br />MAX DC <br />SOLAREDGE <br />S440 OPTIMIZER <br />440W <br />15A <br />98.6 <br />15A <br />60V <br />AHJ/UTILITY NOTES: <br />SOLAREDGE INVERTER EQUIPPED WITH RSD PER 690.12 <br />INSTALLER NOTES: <br />DESIGNER: TAYLOR BICKFORD <br />NEW PV SYSTEM: 6630 DC / 6000 AC <br />Mayela Esparza <br />4205 Fay Cir, Santa Ana, CA 92703 <br />APN: 19833116 <br />8/7/2023DATE: <br />TIME: 02:41 pm <br />REVISION:DATE:DESCRIPTION: <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE: <br />DESIGNER SIGNATURE: <br />LINE DIAGRAM & <br />DESIGN TABLES <br />P6 <br />JURISDICTION STAMPS: <br />EQUIPMENT SPECS <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />4205 W Fay Cir - <br />2018069008/29/23