Laserfiche WebLink
REV:•A <br />AHJ:•CA-CITY•OF•SANTA•ANA <br />33.741744,•-117.870012 <br />APN:•39829218 <br />NAME:•RICHARD•DANG <br />DRAFTED•BY:•SANCHITA•S. <br />ADDRESS:•420•S•BROADWAY,•SANTA <br />ANA,•CA•92701 <br />UTILITY:•SCE-SOUTHERN <br />CALIFORNIA•EDISON <br />SCALE:•AS•NOTED <br />PRN•NUMBER:•ABC-84044 <br />PAPER•SIZE:•17"X11"SHEET:•CS-01DATE:•08/25/2023 <br />DRAWING•INFORMATION <br />CUSTOMER•INFORMATION CONTRACTOR•INFORMATION <br />QC'ED•BY:•GANESH.•K <br />VICINITY•MAP <br />COVER•SHEET <br />RICHARD•DANG•-•5.220kW•DC,•7.600kW•AC,•4.752kW•CEC•AC•RATING <br />APPLICABLE•CODES <br />• ELECTRIC•CODE:CEC•2022 <br />•FIRE•CODE:CFC•2022 <br />•BUILDING•CODE:CBC•2022 <br />•RESIDENTIAL•CODE:CRC•2022 <br />ENGINEERING•SCOPE•OF•WORK <br />1. ILLUMINE•INDUSTRIES•INC.•HAS•ONLY•PROVIDED•DRAFTING•SERVICES•FOR•THE•PERMIT•DRAWINGS.•NO•ACTUAL <br />ENGINEERING•WORK,•ENGINEERING•REVIEW•OR•ENGINEERING•APPROVAL•HAS•BEEN•CONDUCTED•BY•ILLUMINE <br />INDUSTRIES•INC•UNLESS•NOTED•OTHERWISE. <br />2. WHEN•A•PROFESSIONAL•ENGINEER•APPROVES•AND•SEALS•THE•DESIGN•FOR•COMPONENTS•OF•THEIR•RESPECTIVE <br />DISCIPLINE•(STRUCTURAL/ELECTRICAL)•SHOWN•ON•THESE•PERMIT•DRAWINGS,•THE•PROFESSIONAL•ENGINEER <br />a.•TAKES•FULL•DIRECT•CONTROL•OF•THE•ENGINEERED•DESIGN <br />b.•IS•GIVEN•ACCESS•TO•PERSONALLY•SUPERVISE•AND•RECTIFY•ANY•ASPECT•OF•THE•ENGINEERED•DESIGN <br />c.•HAS•FULLY•ACCEPTED•RESPONSIBILITY•FOR•THE•ENGINEERED•DESIGN <br />SCOPE•OF•WORK <br />SYSTEM•SIZE: <br />MODULE: <br />INVERTER: <br />OPTIMIZER: <br />5220W•DC,•7600W•AC,•4752W•CEC•AC <br />RATING <br />(18)JINKO•SOLAR JKM290M-60•(290W) <br />(1)SOLAREDGE•TECHNOLOGIES SE7600H-US <br />(240V)•[SI-1] <br />(18)SOLAREDGE P370•POWER•OPTIMIZER <br />1. MODULES•ARE•LISTED•UNDER•UL•1703•/•61730•AND•CONFORM•TO•THE•STANDARDS. <br />2. INVERTERS•ARE•LISTED•UNDER•UL•1741•AND•CONFORM•TO•THE•STANDARDS. <br />3. DRAWINGS• ARE• DIAGRAMMATIC,• INDICATING• GENERAL• ARRANGEMENT• OF• THE• PV• SYSTEM• AND• THE• ACTUAL• SITE• <br />CONDITION•MIGHT•VARY. <br />4. WORKING• CLEARANCES• AROUND• THE• NEW• PV• ELECTRICAL• EQUIPMENT• WILL• BE• MAINTAINED• IN• ACCORDANCE• WITH• <br />CEC•110.26. <br />5. ALL•GROUND•WIRING•CONNECTED•TO•THE•MAIN•SERVICE•GROUNDING•IN•MAIN•SERVICE•PANEL/•SERVICE•EQUIPMENT. <br />6. ALL•CONDUCTORS•SHALL•BE•600V,•90°C•STANDARD•COPPER•UNLESS•OTHERWISE•NOTED. <br />7. WHEN•REQUIRED,•A•LADDER•SHALL•BE•IN•PLACE•FOR•INSPECTION•IN•COMPLIANCE•WITH•OSHA•REGULATIONS. <br />8. THE•SYSTEM•WILL•NOT•BE•INTERCONNECTED•BY•THE•CONTRACTOR•UNTIL•APPROVAL•FROM•THE•LOCAL•JURISDICTION• <br />AND/OR•THE•UTILITY. <br />9. ROOF• ACCESS• POINT• SHALL• BE• LOCATED• IN• AREAS• THAT• DO• NOT• REQUIRE• THE• PLACEMENT• OF• GROUND• LADDERS• <br />OVER• OPENINGS• SUCH• AS• WINDOWS• OR• DOORS,• AND• LOCATED• AT• STRONG• POINTS• OF• BUILDING• CONSTRUCTION• <br />WHERE•THE•ACCESS•POINT•DOES•NOT•CONFLICT•WITH•OVERHEAD•OBSTRUCTIONS•SUCH•AS•TREES,•WIRES•OR•SIGNS. <br />10. PV•ARRAY•COMBINER/JUNCTION•BOX•PROVIDES•TRANSITION•FROM•ARRAY•WIRING•TO•CONDUIT•WIRING. <br />GENERAL•NOTES <br />RISK•CATEGORY-•ll <br />BASIC•WIND•SPEED••=•95••MPH•@•3-SEC•GUST <br />GROUND•SNOW•LOAD•=•0••PSF <br />DESIGN•CRITERIA <br />PROJECT•WINDSPEED•DETERMINED•USING•THE <br />ASCE•7•STANDARD•UNLESS•DIRECTED•OTHERWISE <br />BY•LOCAL•JURISDICTION•AMENDMENTS <br />ROOF•AREA•CALCULATION <br />TOTAL•ARRAY•AREA =•317.28•sq.ft <br />TOTAL•ROOF•AREA =•1000•sq.ft <br />%•ARRAY•AREA•IN•ROOF• =•31.73•% <br />SHEET•CATALOG <br />SHEET REVISION DESCRIPTION <br />CS-01 COVER•SHEET <br />CS-02 GENERAL•NOTES <br />E-01 SITE•PLAN <br />S-01 MOUNTING•DETAILS <br />S-02 STRUCTURAL•DETAILS <br />E-02 SINGLE•LINE•DIAGRAM <br />E-03 ELECTRICAL•CALCULATIONS <br />PL-01 PLACARDS <br />SS SPEC•SHEET(S) <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />Structural Only: <br />See associated Illumine-i <br />Structural Report for more info. <br />The scope of the plans is for the installation of the solar photovoltaic <br />system only and the approval is subject to compliance with all <br />applicable city and state codes and regulations regarding <br />construction. The approval of the plans does not constitute any <br />certification of the accuracy, completeness, or building permit <br />status of the existing buildings and structures as shown. <br />Bldg#: 101118679 <br />Elec#: 20182412 <br />420 S Broadway- 101118679 & <br />20182412 <br />3/26/2024