Laserfiche WebLink
Project Name: ABC-84044 <br />Structural Report (v.2.3.0) Issued Date: 08/30/2023 <br />Solar Array Installation Calculations: Page | 1 <br />l.Component & Cladding Wind Calculations <br />Site Data <br />Basic Design Wind Speed, V: 95 mph <br />Exposure Category: B <br />Risk Category: II <br />Topo Factor, K : 1.00 <br />Building Data <br />Mean Roof Height, h: 25 ft <br />Building Type: Enclosed <br />Roof Type: Gable <br />Roof Slope: 23 ° <br />Least Horizontal Building Length: 22 ft <br />Largest Horizontal Building Length: 45 ft <br />Estimated Building Area: 990 ft <br />Roof dimension, 'a' per ASCE7: 3 ft <br />Wind Data <br />Velocity Pressure Coef, K : 0.700 <br />Wind Directionality Factor, K : 0.85 <br />Ground Elevation Factor, K : 1.0 <br />Velocity Pressure @ Height, q : 13.7 psf <br />Effective Wind Area, A: 20.0 ft <br />Component & Cladding Wind Pressures <br />Positive Pressure for Effective Area, A = 20 SF* <br />Roof Zone (GCp) (GCpi, +/-)Pressure (psf) <br />*Positive notation indicates wind pressure acting downwards on roof <br />Negative Pressure for Effective Area, A = 20 SF* <br />Roof Zone (GCp) (GCpi, +/-)Pressure (psf) <br />*Negative notation indicates wind pressure acting away from roof <br />*Wind calculations according to ASCE 7-16* <br />To Support Every Human and Every Company on the Planet Achieve Sustainable Living <br />420 S Broadway- 101118679 & <br />20182412 <br />3/26/2024