My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
420 S Broadway - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
420 S Broadway
>
420 S Broadway - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:48 PM
Creation date
6/6/2025 1:22:16 PM
Metadata
Fields
Template:
Plan
Permit Number
20182412
101118679
101119764
Full Address
420 S Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project Name: ABC-84044 <br />Structural Report (v.2.3.0) Issued Date: 08/30/2023 <br />Solar Array Installation Calculations: Page | 3 <br />III.Gravity Loads <br />Roof Dead Loads Roof Dead Loads with Panels <br />Asphalt Shingles:Solar Array <br />1/2" Plywood: <br />Total Existing Dead Load:Total New Dead Load: <br />Roof Live Loads Roof Live Loads with Panels <br />Snow Loads Snow Loads with Panels <br />Ground Snow Load, pg:Thermal Factor, Ct: <br />Snow Exposure Factor, Ce:Flat Roof Snow Load, pf: <br />Snow Importance Factor, Is:Slope Factor, Cs: <br />Thermal Factor, Ct:Sloped Roof Snow Load, ps: <br />Flat Roof Snow Load, pf: <br />Slope Factor, Cs: <br />Sloped Roof Snow Load, ps: <br />Gravity Load Comparison <br />Factored Load Combinations Exist. Weight (psf) New Weight (psf) <br />1.4 DL:5.0 9.2 <br />1.2 DL + 1.6 Lr:29.9 7.9 <br /> Maximum Factored Gravity Loads: <br />% Increase in Factored Weight:-69.1% <br />Roof Live Load @ Location w/ <br />Solar Array: <br />Per Section 503.3 of the 2022 CEBC, any existing gravity load-carrying structural element for which an alteration <br />causes an increase in design dead, live, or snow load, including drift effects, of more than 5% shall be replaced or <br />altered as needed to carry the gravity loads by the CBC for new structures. <br />Since there is no increase of gravity load greater than 5%, the existing structure is adequate for the alteration. <br />Existing Design Roof Live Load <br />(reduced for sloped roof): <br />To Support Every Human and Every Company on the Planet Achieve Sustainable Living <br />420 S Broadway- 101118679 & <br />20182412 <br />3/26/2024
The URL can be used to link to this page
Your browser does not support the video tag.