Laserfiche WebLink
WALLS LAYOUT CEILINGS LAYOUT <br />FLOORS LAYOUT <br />WALK - IN SPECIFICATIONS <br />L <br />U <br />} <br /> <br />1. SUBMITTAL DRAWING NOT INTENDED FOR INSTALLATION. <br /> <br /> AS-BUILT DRAWING FOR INSTALLATION WILL BE AVAILABLE AFTER ORDER IS P LACED. HARD COPY OF AS-BUILT DRAWING WILL BE IN HARDWARE <br /> BOX WITH WALK-IN SHIPMENT TO JOBSITE. ALL AS-BUILT DRAWINGS SHOW PART NUMBERS AND ID LABELS ON PLAN VIEWS. <br /> <br />2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE <br />3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS <br />4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES. INDOOR WALK-INS REQUIRE A <br /> 75°F AMBIENT AND 55% RELATIVE HUMIDITY OR LESS AROUND THE EXTERIOR OF THE WALK-IN. <br />5. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION <br />6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE <br /> CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. <br /> SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS <br />7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS <br />8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE <br />9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES <br />10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE <br /> DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB-SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED <br /> ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT. <br />11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE <br /> DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 915°f; SPONTANEOUS IGNITION TEMPERATURE RATING: 950°f. <br />12. R-VALUES MEET DOE REQUIREMENTS AND ARE ASTM C518 TESTED. COOLER R-VALUES ARE R-29 FOR 4" THICK, R-36 FOR 5" THICK, AND <br /> R-44 FOR 6" THICK PANELS. FREEZER R-VALUES ARE R-32 FOR 4" THICK, R-40 FOR 5" THICK, R-48 FOR 6" THICK PANELS, AND R-29 FOR 4" FLOORS. <br />13. FLOORS NOT DESIGNED FOR WET MOPPING, PALLET JACKS, OR FORKLIFT TRAFFIC. <br /> <br />! ATTENTION <br />DATE:_____________ BY:_____________________________ <br />YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS, <br />FINISHES, DOORS SIZES, LOCATIONS AND SWINGS <br />APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS <br /> DRAWN. <br /> <br />APPROVED AS NOTED - MAKE REQUIRED CHANGES AND <br /> MANUFACTURE AS DRAWN. <br /> <br />NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING <br /> REVISION AND RESUBMISSION. <br /> FOR APPROVAL <br />SMOOTH FINISH DISCLAIMER <br />Panels with non-textured and/or no-profile panel finishes (smooth finishes) on the <br />exterior and interior faces may exhibit “oil canning" and flatness imperfections on the <br />surface. Our standard panels have a stucco embossed texture on both faces that helps to <br />reduce oil canning and any other irregularities in the exposed surface. Please be aware <br />of this potential situation in your specification process. Such “oil canning” and flatness <br />issues are typical and are not covered under standard warranties. <br /> <br />D <br />AT <br />E: <br />QUOTE <br />R <br />EVISI <br />ON <br />D <br />EL TAC <br />O - STANTON <br /> STANTON,CA 90680 USA <br />A <br />VAN <br />TI RES <br />TAUR <br />ANT <br />S <br />OLUTIO <br />NS <br />AD-1 of 2 <br />DR <br />AWING #: <br />2915 Tennes <br />see A <br />ven <br />ue Nor <br />th, Par <br />sons <br />, T <br />N 3 <br />8363 (731) 847 <br />-636 <br />1 *(8 <br />00) 826- <br />7036* <br /> <br /> <br /> <br /> <br />0 <br />4/20 <br />/ <br />20 <br />21 <br />DATE <br />: <br />CHECK <br /> B <br />Y: <br />D <br />ATE <br />: <br />KAD <br />D <br />RAW <br />N B <br />Y: <br />SHEET # <br /> <br />A <br />188429R <br />1 <br />0 <br />01 <br />® <br />UNI <br />T #: <br />O <br />RDER #: <br />}NSF <br />Kolpak and Harford walk-ins are compliant with UL standards. <br />• Door panels are UL471, UL file listing E46140. <br />• Standard Evaporator coils are UL412. <br />•Condensing Units are UL1995. <br /> <br /> <br />U NOTICE:L} <br />F01 - <br />FREEZER : <br />W/FLOOR <br />9' - 0 1/4" O.A. HEIGHT <br />8' - 4 5/8" I.D. <br />PANELS <br />FOAMED IN PLACE URETHANE FOAM 4" <br /> <br />EXTERIOR FINISH <br />WALL: GALVALUME - EMBOSSED 26 GA <br />TOP: GALVALUME - EMBOSSED 26 GA <br />FLOOR: GALVALUME - EMBOSSED 26 GA <br /> <br /> <br />INTERIOR FINISH <br />WALL: ALUMINUM - EMBOSSED WHITE .040 <br />TOP: ALUMINUM - EMBOSSED WHITE .040 <br /> <br /> <br />FLOOR TYPE <br />F01 FREEZER : <br /> STANDARD 1000# ERA <br /> ALUMINUM - SMOOTH ALUMINUM .100 <br /> <br /> <br /> <br />WALK-IN ACCESSORIES <br />(50) COVE BASE, ALUMINUM EMBOSSED WHITE .040 1.25 X 4.25 <br />(1) LIGHT FIXTURE - KASON 1810LC LED 48IN 120/230V 50/60HZ (DIODE STRIPS) <br />(7) TIE DOWN ANGLE - 1-1/2" X 1-1/2" X 96" (INT WALL TO CL INCL PARTITIONS) <br />(3) TRIM ANGLED 3" X 3" X 8FT GALVALUME EMBOSSED 26 GA <br /> <br /> <br />REFRIGERATION <br />F01 FREEZER : <br /> KPC198LZOP-2E, R448A, VOLTS: 208-230-60-1,BTU:6240 <br /> KEL16-049-2EC-PR-8 VOLTS: 208-230-60-1,BTU:6503 <br /> TEMP: WALK-IN -10,AMBIENT TEMP: 90 <br /> <br /> <br /> <br /> <br />6'-93 4 " <br />7'-53 4 " <br />6'-7 <br />" <br />7'-3 <br />" <br />36 <br />1 <br />4" <br />2 <br />13 <br />8" <br />2 <br />13 <br />8" <br />4 <br />31 <br />2 <br />" <br />431 <br />2" <br />1'-3 <br />" <br />A <br />Freezer <br />OVERALL SIZE: 7'-5 3/4" X 7'-3" X 9'-0 1/4" (INDOOR) <br /> <br />6'-9 3/4" <br />6'-11" X 7'-8 1/2" X 9-0 1/4" <br />6' <br />- <br />1 <br />1 <br />" <br />6' <br />- <br />3 <br />" <br />7'-8" <br />EQ <br />EQ <br />CL 42.5 X 92.75 <br />CL 40.5 X 92.75 <br />FL 42.5 X 92.75 <br />FL 40.5 X 92.75 <br />EQ <br />EQ <br />DAVID M <br />FULTON <br />C89429 <br />^WIL-EN®NBErR <br />SIGNED 2-21-2024 <br />2300 N Tustin Ave - <br />101117751-52 & 30146715 <br />8/22/2024