My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2210 3%4 N Grand Ave Unit# WCC01 - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
2210 3/4 N Grand Ave Unit# WCC01
>
2210 3%4 N Grand Ave Unit# WCC01 - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:54 PM
Creation date
6/6/2025 1:22:17 PM
Metadata
Fields
Template:
Plan
Permit Number
101118404
101122299
Full Address
2210 3/4 N Grand Ave Unit# WCC01
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 1:22 PM
Modified:
5/30/2025 3:20 PM
Text:
EPIRATION: 06/30/2024
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXISTING/DEMOLITION AND <br />PROPOSED ONE-LINE <br />DIAGRAMS <br />21 <br />FROM (E) POWER SOURCE <br />M <br />(E) <br />NORMAL <br />2P/200A <br />120/240V, 1Ø, 3W, 200A, 65 KAIC <br />(E)(E) <br />2P <br />200A <br />(E) METER PEDESTAL, <br />120/240V, 1Ø, 200A, 42 KAIC <br />TO REMAIN <br />(E) <br />E6160 <br />(N) EQUIP. <br />CABINET <br />(E) GENERATOR <br />RECEPTACLE <br />(OPTIONAL) <br />TO (E) LOADS <br />EMERGENCY <br />2P/200A <br />(E) POWER PANEL 'A' LOCATED <br />AT LEASE AREA <br />(N) (2) 2"C <br />(APPROX 1') <br />(NOTE) <br />B160 <br />(N) EQUIP. <br />CABINET <br />(E) SINGLE LINE DIAGRAM (N) SINGLE LINE DIAGRAM <br />MECHANICAL <br />INTERLOCK <br />NOTES: <br />1.ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT ADOPTED NATIONAL <br />ELECTRIC CODES AND ALL LOCAL AND STATE CODES, LAWS, AND ORDINANCES. PROVIDE ALL <br />COMPONENTS AND WIRING SIZES AS REQUIRED TO MEET NEC. <br />2.ALL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 AND CONDUIT EXPOSED ABOVE <br />GROUND SHALL BE RIGID GALVANIZED STEEL, INTERIOR CONDUIT SHALL BE EMT UNLESS OTHERWISE <br />INDICATED. POWER CONDUIT LINES SHALL BE SIZED AS REQUIRED PER CABLE SIZING AND NEC <br />REQUIREMENTS. <br />3.CONDUITS INSTALLED AT BTS EQUIPMENT ENDS PRIOR TO THE EQUIPMENT INSTALLATION SHALL BE <br />STUBBED AND CAPPED AT 6" ABOVE GRADE OR PLATFORM. IF SERVICE LINES CAN'T BE INSTALLED <br />INITIALLY, PROVIDE NYLON PULL CORD IN CONDUITS. <br />4.LABEL ALL T-MOBILE CONDUITS EVERY 20' THROUGH THE BUILDING AND ON THE ROOF, "T-MOBILE" <br />USING STENCILS AND SPRAY PAINT. THIS APPLIES TO EXISTING T-MOBILE CONDUITS AS WELL. <br />FROM (E) POWER SOURCE <br />M <br />(E) <br />NORMAL <br />2P/200A <br />120/240V, 1Ø, 3W, 200A, 65 KAIC <br />(E)(E) <br />2P <br />200A <br />2P <br />150A <br />(E) GENERATOR <br />RECEPTACLE <br />(OPTIONAL) <br />TO (E) LOADS <br />(N) <br />EMERGENCY <br />2P/200A <br />(E) POWER PANEL 'A' LOCATED <br />AT LEASE AREA <br />EXISTING PPC (SEE DETAIL 2/E-2 FOR <br />PANEL SCHEDULE) WITH TWO 200A <br />MECHANICALLY INTERLOCKED <br />CIRCUIT BREAKERS THAT ACT AS A <br />MANUAL TRANSFER SWITCH, BREAK <br />BEFORE MAKE. NEMA 3R ENCLOSURE <br />MECHANICAL <br />INTERLOCK <br />RBS 6131 <br />TO REMAIN <br />(E) EQUIP. <br />CABINET <br />EXISTING PPC (SEE DETAIL 1/E-2 FOR <br />PANEL SCHEDULE) WITH TWO 200A <br />MECHANICALLY INTERLOCKED <br />CIRCUIT BREAKERS THAT ACT AS A <br />MANUAL TRANSFER SWITCH, BREAK <br />BEFORE MAKE. NEMA 3R ENCLOSURE <br />(N) 2"C <br />(APPROX 4') <br />(NOTE) <br />(E)1-1/2" C W/ (3) #2 & <br />(1) #8 GND <br />TO REMAIN <br />2P <br />100A <br />(E) <br />(E)1-1/2" C W/ (3) #2 & <br />(1) #8 GND TO REMAIN <br />(N) 1-1/2" C W/ (3) #1/0 & <br />(1) #6 GND <br />Fax: (818) 840-0708 <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 <br />advantage engineersa division of <br />Fax: (818) 840-0708 <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 <br />advantage engineersa division of <br />Stick Together <br />CONSTRUCTION <br />E-1 3 <br />SITE NUMBER: <br />SITE NAME: <br />LA3642 SCE LAVETA SUB CS <br />LA23642A <br />2210 3/4 N. GRAND AVE.SANTA ANA, CA 92705 <br />CROWN BU: 825183 <br />12/15/22 <br />2P <br />100A <br />(E) <br />RBS 6131 <br />TO REMAIN <br />(E) EQUIP. <br />CABINET <br />(E) METER PEDESTAL, <br />120/240V, 1Ø, 200A, 42 KAIC <br />TO REMAIN <br />(E) <br />(E)CONDUIT & <br />CONDUCTORS TO <br />REMAIN <br />(E)CONDUIT & <br />CONDUCTORS TO <br />REMAIN <br />(E)CONDUIT & <br />CONDUCTORS TO <br />REMAIN <br />(E)CONDUIT & <br />CONDUCTORS TO <br />REMAIN <br />2P <br />50A <br />(E) <br />RBS 2106 <br />TO REMAIN <br />(E) EQUIP. <br />CABINET <br />(E)1" C W/ (3) #6 & (1) <br />#10 GND <br />TO REMAIN <br />RBS 2106 <br />TO REMAIN <br />2P <br />50A <br />(E) <br />(E)1" C W/ (3) #6 & (1) #10 <br />GND TO REMAIN <br />(E) EQUIP. <br />CABINET <br />2P <br />50A <br />(E) <br />RBS 2102 <br />TO REMAIN <br />(E) EQUIP. <br />CABINET <br />(E)1" C W/ (3) #6 & (1) <br />#10 GND <br />TO BE REMOVED <br />12/29/2022 <br />2210 3%4 N Grand Ave Unit# <br />WCC01 - 101118404 <br />5/30/2024
The URL can be used to link to this page
Your browser does not support the video tag.