Laserfiche WebLink
ELECTRICAL NOTES <br />Fax: (818) 840-0708 <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 <br />advantage engineersa division of <br />Fax: (818) 840-0708 <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 <br />advantage engineersa division of <br />Stick Together <br />CONSTRUCTION <br />E-3 3 <br />SITE NUMBER: <br />SITE NAME: <br />LA3642 SCE LAVETA SUB CS <br />LA23642A <br />2210 3/4 N. GRAND AVE.SANTA ANA, CA 92705 <br />CROWN BU: 825183 <br />12/15/22 <br />GENERAL ELECTRICAL NOTES & BASIC ELECTRICAL REQUIREMENTS <br />1.THE DRAWINGS ARE PROVIDED TO DEPICT DESIGN INTENT AND ARE NOT TO BE CONSIDERED INSTALLATION DRAWINGS. <br />NOT ALL COMPONENTS OR CONNECTIONS ARE SHOWN. EQUIPMENT PART NUMBERS ARE SHOWN TO PROVIDE <br />PERFORMANCE CRITERIA AND LEVEL OF PRODUCT STANDARDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />DETERMINING FINAL CONDUIT ROUTING, INSTALLATION OF ALL ELECTRICAL EQUIPMENT, COMPONENTS AND MATERIALS. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL INSTALLATION MEANS AND METHODS. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR INSTALLING, ENERGIZING AND TESTING OF ALL ELECTRICAL COMPONENTS PER THE MANUFACTURER'S <br />INSTRUCTIONS. <br />2.CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE <br />BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS <br />PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE ADVANTAGE ENGINEERS PROJECT MANAGER OR <br />CONSTRUCTION MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. <br />3.CONTRACTOR SHALL PERFORM ALL VERIFICATION, OBSERVATION, TESTS, AND EXAMINATION WORK PRIOR TO THE <br />ORDERING OF THE ELECTRICAL EQUIPMENT AND THE ACTUAL CONSTRUCTION. CONTRACTOR SHALL ISSUE A WRITTEN <br />NOTICE OF ALL FINDINGS TO THE DESIGN PROFESSIONAL LISTING ANY AND ALL MALFUNCTIONS, FAULTY EQUIPMENT AND <br />DISCREPANCIES. <br />4.THE CONTRACTOR SHALL NOTIFY THE DESIGN PROFESSIONAL, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS <br />PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS <br />SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. <br />5.THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGN PROFESSIONAL OF ANY UNFORESEEN SITE CONDITIONS THAT <br />MAY IMPACT THE DESIGN. <br />6.THE CONTRACTOR IS IN NO WAY PERMITTED TO MODIFY OR CHANGE THE DESIGN WITHOUT THE EXPRESS, WRITTEN <br />CONSENT OF THE DESIGN PROFESSIONAL. SHOULD THE CONTRACTOR MAKE MODIFICATIONS TO THE DESIGN WITHOUT THE <br />CONSENT OF THE DESIGN PROFESSIONAL, THE CONTRACTOR ASSUMES ALL RESPONSIBILITY AND LIABILITY FOR SUCH <br />CHANGES. <br />7.THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, LAWS AND REGULATIONS OF ALL <br />MUNICIPALITIES, UTILITY COMPANIES, THE AUTHORITY HAVING JURISDICTIONS OR OTHER PUBLIC AUTHORITIES. <br />8.ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE <br />AND OTHER APPLICABLE CODES. <br />9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY <br />FEDERAL, STATE, COUNTY OR LOCAL MUNICIPAL AUTHORITIES. <br />10.CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION CONSTRUCTION TOOLS, <br />TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AS INDICATED IN <br />THE CONSTRUCTION DOCUMENTS, AS SPECIFIED HEREIN AND/OR AS OTHERWISE REQUIRED. <br />11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING <br />CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS <br />FACILITY. <br />12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING OF THE WORK SITE AND REMOVING ALL TRASH AND DEBRIS ON <br />A DAILY BASIS. <br />13.THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED <br />TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATIONS. <br />14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATING, DRAINING, TRENCHES, BACKFILLING, AND REMOVAL OF <br />EXCESS DIRT. <br />15.ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST <br />GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS <br />SHALL BE LISTED AND APPROVED BY UNDERWRITER'S LABORATORIES (U.L.) AND SHALL BEAR THE INSPECTION LABEL “J” <br />WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH THE APPROVAL OF ALL GOVERNING BODIES HAVING <br />JURISDICTION AND SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, <br />NFPA, IBC, IMC, IECC, IEC, NEC, IEEE, ASTM, NEMA, U.L. AND NBFU. <br />16.LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE <br />COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN. <br />17.THE CONDUIT RUNS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING SHALL BE PER EXISTING <br />FIELD CONDITIONS. <br />18.ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING EQUAL TO OR GREATER THAN THE SHORT <br />CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED; 22,000 AIC MINIMUM FOR MAINS AND 10,000 AIC MINIMUM FOR <br />BRANCH DEVICES. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL <br />EQUIPMENT. <br />19.ALL NEW INSTALLED ELECTRICAL EQUIPMENT SHALL BE FURNISHED WITH ARC FLASH HAZARD LABELS AS REQUIRED BY THE <br />NEC. <br />20.ALL ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO: DISCONNECT SWITCHES, TRANSFORMERS, PANELBOARDS, <br />POWER PROTECTION CABINET (PPC), AUTOMATIC TRANSFER SWITCH (ATS), MANUAL TRANSFER SWITCH (MTS), POWER <br />TRANSFER LOAD CENTER (PTLC), ETC., SHALL BE LABELED WITH PERMANENT ENGRAVED PLASTIC LABELS. LABELS SHALL <br />INDICATE EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. <br />21.THE CONTRACTOR SHALL PREPARE A COMPLETE SET OF AS-BUILT DRAWINGS, DOCUMENT ALL WIRING EQUIPMENT <br />CONDITIONS, INCLUDING MANUFACTURER'S AND PART NUMBERS FOR PANELBOARDS, TRANSFORMERS, POWER <br />PROTECTION CABINETS (PPC) AND DISCONNECTS, AND CHANGES WHILE COMPLETING THIS CONTRACT. THE AS-BUILT <br />DRAWINGS SHALL BE SUBMITTED TO THE DESIGN PROFESSIONAL AT THE COMPLETION OF THE PROJECT. <br />22.UPON COMPLETION OF WORK, THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL EXPOSED EQUIPMENT, REMOVE <br />DEBRIS, CRATING AND CARTONS AND LEAVE THE INSTALLATION FINISHED AND READY FOR OPERATION. <br />23.THE CONTRACTOR SHALL NOTIFY THE BUILDING OWNER FIVE (5) BUSINESS DAYS PRIOR TO ANY PLANNED POWER OR <br />OTHER SERVICE OUTAGE. THE OWNER SHALL RESERVE THE RIGHT TO REFUSE SUCH OUTAGE AND HAVE IT RESCHEDULED. <br />24.ANY CODE VIOLATIONS DUE TO THE CONTRACTOR'S WORK SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. <br />ELECTRICAL SPECIFICATIONS: ELECTRICAL MATERIALS AND EQUIPMENT <br />CONDUIT <br />1.RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN <br />UNFINISHED INTERIOR LOCATIONS AND WHERE INDICATED ON THE DRAWINGS, FOR UNDERGROUND RUNS. RIGID <br />CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING <br />PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFICATION WW-C-581 AND <br />SHALL BE LISTED WITH THE UNDERWRITER'S LABORATORIES. FITTINGS SHALL BE THREADED - SET SCREW OR <br />COMPRESSION FITTINGS WILL NOT BE ACCEPTED. <br />2.UNDERGROUND CONDUIT SHALL BE POLYVINYLCHLORIDE SCHEDULE 40 (PVC). SCHEDULE 40 PVC SHALL NOT BE <br />PERMITTED ABOVE GRADE. WHERE CONDUIT PASSES UNDER A ROAD OR DRIVE, IT SHALL BE SCHEDULE 80 PVC. <br />SUITABLE FOR DIRECT BURIAL. JOINTS SHALL BE BELLED, AND FLUSH, SOLVENT WELDED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />3.EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED INTERIOR SPACES, CONCEALED IN WALLS <br />AND CEILINGS. EMT SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO-GALVANIZED OR HOT-DIPPED <br />GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW-C-563, AND SHALL BE <br />U.L. LISTED. FITTING SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS ARE NOT PERMITTED. <br />4.LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO EQUIPMENT. FITTINGS SHALL <br />BE METALLIC GLAND TYPE COMPRESSION FITTINGS, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW <br />CONNECTIONS ARE NOT PERMITTED. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED SIX (6) FEET, <br />EXCEPT WHERE PERMITTED BY THE NEC. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRED BY THE NEC. <br />5.MINIMUM SIZE CONDUIT SHALL BE ¾ INCH. <br />6.PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY THE NEC. <br />7.PROVIDE VERTICAL CABLE SUPPORTS IN ALL VERTICAL CONDUITS WHERE SHOWN OR REQUIRED BY THE NEC. <br />8.PROVIDE EXPANSION FITTINGS IN CONDUIT WHERE SHOWN OR REQUIRED BY THE NEC. <br />9.ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC. NO RIGHT ANGLE DEVICE OTHER <br />THAN STANDARD CONDUIT ELBOWS WITH 12 INCH MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2 INCH OR LARGER. <br />10.THERE SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL) BETWEEN PULL <br />BOXES, CONDUIT BODIES AND BOXES. CONTRACTOR SHALL FURNISH AND INSTALL ANY/ALL JUNCTION BOXES SIZED <br />IN ACCORDANCE WITH THE NEC REQUIREMENTS AS REQUIRED FOR THE INSTALLATION. <br />11.ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUND BUSHINGS. <br />12.CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL CONDUITS DURING CONSTRUCTION. <br />13.TEMPORARY OPENINGS IN THE CONDUIT SYSTEM SHALL BE PLUGGED OR CAPPED TO PREVENT ENTRANCE OF <br />MOISTURE OR FOREIGN MATTER. CONTRACTOR SHALL REPLACE ANY CONDUITS CONTAINING FOREIGN MATERIALS <br />THAT CANNOT BE REMOVED. <br />14.ALL CONDUITS SHALL BE SWABBED CLEAN BY PULLING AN APPROPRIATELY SIZED MANDREL THROUGH THE CONDUIT <br />BEFORE INSTALLATION OF CONDUCTORS OR CABLES. CONDUIT SHALL BE FREE OF DIRT AND DEBRIS. <br />15.INSTALL PULL STRINGS IN ALL CLEAN EMPTY CONDUITS. IDENTIFY PULL STRINGS AT EACH END. <br />16.INSTALL 2” HIGHLY VISIBLE AND DETECTABLE TAPE 12” ABOVE ALL UNDERGROUND CONDUIT AND CONDUCTORS, <br />OR AS INDICATED ON THE DRAWINGS. <br />17.CONDUITS SHALL BE INSTALLED IN SUCH A MANNER AS TO ENSURE AGAINST COLLECTION OF TRAPPED <br />CONDENSATION. <br />18.PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS TO ALLOW FOR RACEWAYS AND CABLES TO BE <br />ROUTED THROUGH THE BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS. SLEEVES AND/OR PENETRATIONS IN <br />FIRE RATED CONSTRUCTION (WALLS AND FLOORS) SHALL BE EFFECTIVELY SEALED WITH FIRE RATED MATERIAL WHICH <br />SHALL MAINTAIN THE FIRE RATING OF THE WALL, FLOOR OR STRUCTURE. FIRE STOPS AT FLOOR PENETRATIONS SHALL <br />PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE U.L. APPROVED FOR THIS PURPOSE. <br />19.CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. <br />EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE ARE NOT PERMITTED. CLOSELY FOLLOW THE LINES OF <br />THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. <br />CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO THE <br />STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS <br />SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE <br />RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE <br />IRON LOCKNUT ON OUTSIDE AND INSIDE. <br />20.SPARE CONDUITS SHALL BE FURNISHED WITH PULL LINES AND CAPPED WITH FACTORY CAPS. <br />CONDUCTORS <br />1.CONDUCTORS AND CABLE SHALL BE FLAME-RETARDANT, MOISTURE AND HEAT RESISTANT THERMOPLASTIC, SINGLE <br />CONDUCTOR, COPPER, TYPE THHN/THWN-2, 600 VOLT, OR TYPE XHHW, 600V OR XHHW-2, 600V. SIZE AS INDICATED. <br />#12 AWG SHALL BE THE MINIMUM SIZE CONDUCTOR. <br />2.#10 AWG AND SMALLER CONDUCTORS SHALL BE SOLID AND #8 AWG AND LARGER CONDUCTORS SHALL BE <br />STRANDED. <br />3.SOLDERLESS, COMPRESSION-TYPE CONNECTORS SHALL BE USED FOR TERMINATION OF ALL STRANDED <br />CONDUCTORS. <br />4.ALL CONDUCTORS SHALL BE TAGGED AT BOTH ENDS OF THE CONDUCTOR, AT ALL PULL BOXES, JUNCTION BOXES, <br />EQUIPMENT AND CABINETS AND SHALL BE IDENTIFIED WITH APPROVED PLASTIC TAGS. <br />5.5.CONTRACTOR SHALL PROVIDE STRAIN-RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES, COAX <br />CABLES, AND AISG RET CABLES. CABLE STRAIN-RELIEF & CABLE SUPPORTS SHALL BE APPROVED FOR THE PURPOSE. <br />ZIP TIES OR VELCRO STRAPS ARE NOT PERMITTED. <br />ELECTRICAL SPECIFICATIONS: ELECTRICAL MATERIALS AND EQUIPMENT, CONTINUED <br />DISCONNECT SWITCHES <br />1.DISCONNECT SWITCHES SHALL BE HEAVY DUTY, FUSIBLE, DEAD FRONT, QUICK-MAKE, QUICK-BREAK, EXTERNALLY <br />OPERABLE, HANDLE LOCKABLE AND INTERLOCK WITH COVER IN CLOSED POSITION, VOLTAGE, AMPERAGE AND NEMA <br />RATING AS INDICATED. <br />2.INSTALL DISCONNECT SWITCHES LEVEL AND PLUMB. CONNECT TO WIRING SYSTEM AND GROUNDING SYSTEM AS <br />INDICATED. <br />3.PROVIDE A WHITE PHENOLIC SIGN WITH ¾” RED ENGRAVED LETTERING LABELING EACH SERVICE DISCONNECT AS <br />“SERVICE DISCONNECT”. IF SOURCE IS HOUSE POWER, INCLUDE LOCATION AND LABEL OF PANEL FEEDING EQUIPMENT. <br />HVAC DISCONNECTS SHALL BE LABELED “HVAC DISCONNECT” AND INCLUDE PANEL AND CIRCUIT NUMBER OF CIRCUIT <br />SERVING THE HVAC EQUIPMENT. <br />4.ALL FUSIBLE DISCONNECTS SHALL BE FURNISHED WITH CLASS RK-1 FUSES, SIZED AS INDICATED. <br />PANELBOARDS <br />1.RATED FOR USE AT 120/240V, SINGLE PHASE, THREE WIRE PLUS GROUND, OR 120/208V, SINGLE PHASE, THREE WIRE PLUS <br />GROUND OR 120/208V, THREE PHASE, FOUR WIRE PLUS GROUND AS REQUIRED FOR THE INTENDED APPLICATION OR AS <br />INDICATED ON THE DRAWINGS. <br />2.ALUMINUM OR COPPER BUS, RATED FOR 200 AMPERES OR AS INDICATED ON THE DRAWINGS, AND HAVE A SHORT <br />CIRCUIT WITHSTAND RATING OF 22,000 AIC MINIMUM. <br />3.MAIN CIRCUIT BREAKER SHALL BE 200 AMPERES OR AS INDICATED ON THE DRAWINGS AND HAVE A SHORT CIRCUIT <br />RATING OF 22,000 AIC MINIMUM. THE MAIN BREAKER SHALL NOT BE INSTALLED SO AS TO BACKFEED THE PANEL BUS. <br />4.PANEL SHALL HAVE A NUMBER OF BRANCH CIRCUITS AS INDICATED ON THE DRAWINGS. THE MAIN BREAKER SHALL NOT <br />USE ANY OF THESE SPACES. <br />5.BRANCH CIRCUIT BREAKERS SHALL BE PLUG-IN OR BOLT-ON TYPE. <br />6.BRANCH CIRCUIT BREAKERS SHALL HAVE A MINIMUM RATING OF 10,000 AIC. <br />7.TANDEM BRANCH CIRCUIT BREAKERS ARE NOT PERMITTED. <br />8.PANEL ENCLOSURE SHALL BE NEMA 1 FOR INTERIOR APPLICATIONS OR NEMA 3R FOR EXTERIOR APPLICATIONS OR AS <br />INDICATED ON THE DRAWINGS. <br />9.DO NOT INSTALL PANEL UPSIDE DOWN. <br />10.WHERE A PANELBOARD IS INSTALLED, AN EXTERNAL SURGE PROTECTION DEVICE MUST ALSO BE INSTALLED ADJACENT <br />AND CONNECTED TO THE PANELBOARD. <br />11.QUALITY PRODUCT CIRCUIT BREAKERS ARE NOT PERMITTED. <br />12.UNUSED BRANCH CIRCUIT SPACES SHALL HAVE PANEL MANUFACTURER'S BLANK SPACE INSERTS INSTALLED. <br />13.ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN, NOT HANDWRITTEN. <br />14.PANEL DIRECTORIES SHALL BE UPDATED TO ACCURATELY REFLECT THE FINAL CIRCUITING. <br />15.ALL UNUSED CIRCUIT BREAKERS SHALL BE SWITCHED OFF AND LABELED “SPARE”. <br />EXTERNALLY MOUNTED SURGE PROTECTION DEVICES <br />1.RATED FOR THE INTENDED APPLICATION AND AS INDICATED ON THE DRAWINGS: 120/240V, SINGLE PHASE, OR <br />120/208V, SINGLE PHASE, OR 120/208V, THREE PHASE, OR 480/277V, SINGLE PHASE OR 480/277V, THREE PHASE. <br />2.RATED FOR 100KA PEAK SURGE CURRENT PER PHASE. <br />3.INDICATOR LEDS FOR NORMAL AND FAULT CONDITION FOR EACH PHASE. <br />4.U.L. LISTED 1449 <br />5.ENCLOSURE SHALL BE: INTERIOR APPLICATIONS, NEMA 1. EXTERIOR APPLICATIONS: NEMA 3R OR NEMA 4 OR NEMA 4X <br />STAINLESS STEEL. <br />POWER PROTECTION CABINET (PPC) <br />1.RATED FOR USE AT 120/240V, SINGLE PHASE, THREE WIRE PLUS GROUND OR 120/208V, SINGLE PHASE, THREE WIRE PLUS <br />GROUND OR 120/208V, THREE PHASE, FOUR WIRE PLUS GROUND AS REQUIRED FOR THE INTENDED APPLICATION OR AS <br />INDICATED ON THE DRAWINGS. <br />2.ALUMINUM OR COPPER BUS, RATED FOR 200 AMPERES OR AS INDICATED ON THE DRAWINGS, AND HAVE A SHORT <br />CIRCUIT WITHSTAND RATING OF 22,000 AIC MINIMUM. <br />3.TWO MAIN CIRCUIT BREAKERS, MECHANICALLY INTERLOCKED, THAT ACT AS A MANUAL TRANSFER SWITCH, BREAK <br />BEFORE MAKE. ALLOW FOR A NORMAL AND PORTABLE GENERATOR STANDBY FEEDS. MAIN BREAKERS SHALL BE 200 <br />AMPERES AND HAVE A SHORT CIRCUIT RATING OF 22,000 AIC MINIMUM. CONTRACTOR SHALL ENSURE THAT THE <br />MECHANICAL INTERLOCK HAS BEEN INSTALLED. <br />4.INTERNAL PANEL SHALL HAVE A MINIMUM OF 24 BRANCH CIRCUITS AVAILABLE. <br />5.BRANCH CIRCUIT BREAKERS SHALL BE PLUG-IN OR BOLT-ON. <br />6.BRANCH CIRCUIT BREAKERS SHALL HAVE A MINIMUM RATING OF 10,000 AIC. <br />7.TANDEM BRANCH CIRCUIT BREAKERS ARE NOT PERMITTED. <br />8.CLASSIFIED PRODUCT CIRCUIT BREAKERS ARE NOT PERMITTED. <br />9.FURNISHED WITH INTERNAL, FACTORY INSTALLED, INTEGRATED SURGE SUPPRESSION. <br />10.FURNISHED WITH STANDBY GENERATOR INLET (RECEPTACLE), REVERSE SERVICE RATED. VOLTAGE AND AMPERAGE AS <br />INDICATED ON THE DRAWINGS. GENERATOR RECEPTACLE SHALL BE FACTORY INSTALLED ON SIDE OF PPC UNLESS <br />SHOWN AS REMOTE MOUNTED ON THE DRAWINGS. <br />11.UNUSED BRANCH CIRCUIT BREAKERS SHALL HAVE PANEL MANUFACTURER'S BLANK SPACE INSERTS INSTALLED. <br />12.ENCLOSURE SHALL BE NEMA 1 FOR INTERIOR APPLICATIONS OR NEMA 3R FOR EXTERIOR APPLICATIONS OR AS <br />INDICATED ON THE DRAWINGS. <br />13.IF AN EXISTING PPC IS MISSING THE MECHANICAL INTERLOCK, THE CONTRACTOR SHALL FURNISH AND INSTALL THE <br />CORRECT FACTORY MECHANICAL INTERLOCK ON THE TWO MAIN CIRCUIT BREAKERS. <br />14.ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN, NOT HANDWRITTEN. <br />15.PANEL DIRECTORIES SHALL BE UPDATED TO ACCURATELY REFLECT THE FINAL CIRCUITING. <br />16.ALL UNUSED CIRCUIT BREAKERS SHALL BE SWITCHED OFF AND LABELED “SPARE”. <br />EXTERIOR COMBINATION GFCI/SWITCH UNIT <br />1.WEATHERPROOF ENCLOSURE WHICH INCLUDES A 120V, 20A GFCI RECEPTACLE AND A 120V, 20A TOGGLE SWITCH. <br />“IN-USE” COVER, CORROSION RESISTANT, GALVANIZED STEEL ENCLOSURE. <br />3.GFCI RECEPTACLE AND LIGHT SWITCH SHALL BE WIRED ON SEPARATE CIRCUITS, UNLESS OTHERWISE NOTED ON THE <br />DRAWINGS. <br />4.G.E. # U010S010GRP OR APPROVED EQUAL. <br />12/29/2022 <br />2210 3%4 N Grand Ave Unit# <br />WCC01 - 101118404 <br />5/30/2024