Laserfiche WebLink
STRING 1: (12x) Qcells North America Q.PEAK <br />DUO BLK ML-G10+ 405 PV MODULES <br />WITH 12 S440 SE POWER OPTIMIZERS <br />1 <br />JUNCTION BOX <br />- NEMA 3R <br />AS REQUIRED <br />2 <br />(N) INVERTER <br />SOLAREDGE <br />SE3800H-US (ENERGY HUB) <br />RGM (240V) [SL1] <br />3+- <br />+- <br />+- <br />+- <br />+- <br />+-1221 <br />= <br />DC AC <br />METER NUMBER: 222013-000656 <br />TO UTILITY GRID <br />OVERHEAD <br />(E) 100A <br />M <br />M <br />(E)200A GROUPEDMETERING CABINET <br />240/120v 1-PH, 3-W <br />POINT OF INTERCONNECTION <br />LOAD SIDE 705.12(B)(3)(3) <br />(1) (N) <br />SOLAREDGE <br />ENERGY BANK <br />BAT-10K1P <br />5.0kW, 9.7kWh4 <br />DC DISCONNECT <br />600V, 30A <br />4 <br />(N)20A <br /> (E)125A SUB PANEL <br />120/240V <br />NEMA 3R UL LISTED <br />E <br />(E) GROUNDING <br />ELECTRODE <br />(COPPER) <br />GROUND <br />ROD <br />ROOFTOP CONDUIT SHALL BE A MINUMUM <br />OF 7/8" ABOVE THE ROOF SURFACE <br />CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS <br />ID CONDUCTOR (CU)CONDUIT CONDUCTORS <br />IN CONDUIT EGC TEMP. CORR. <br />FACTOR <br />CONT. <br />CURRENT <br />MAX. CURRENT <br />(125%)BASE AMP.DERATED <br />AMP. <br />TERM. TEMP. <br />RATING <br />2 3/4" EMT 2 & (1)G #8 15 18.75 40 36.4 900.91#10 THWN-2, in conduit <br />1 #10 PV Wire, in open air N/A N/A #6 15 18.75 40 36.4 900.91 <br />#10 THWN-2, in conduit 3/4" EMT 3 & (1)G #8 0.91 16 20 40 38.4 903 <br />4 0.91#10 THWN-2, in conduit 3/4" EMT #8 40 36.4 902 & (1)G 12.5 15.625#10 THWN-2, in conduit <br />DESIGN TEMPERATURES <br />ASHRAE 2% HIGH <br />30°C <br />2°C <br />ASHRAE EXTREME LOW <br />INVERTER 1 SPECS <br />SE3800H-US (ENERGY HUB)_RGM <br />AC VOLTAGE <br />240V <br />GROUND <br />0.99 <br />MAX OCPD <br />20A <br />RATED POWER <br />3800W <br />MAX OUTPUT <br />16A <br />MAX INPUT <br />11A <br />MAX INPUT <br />480V <br />EFFICIENCY <br />0.99CEC <br />POWERBOX MAX OUTPUT CURRENT <br />OPTIMIZERS IN SERIES <br />NOMINAL STRING VOLTAGE <br />ARRAY OPERATING CURRENT <br />STRING DETAILS <br />STRING CALCULATIONS - INVERTER 1 <br />STRING 1 <br />15A <br />12 <br />380V <br />16A <br />SYSTEM SUMMARY <br />ARRAY STC POWER <br />4860W <br />ARRAY PTC POWER <br />4515.6W <br />MAX AC CURRENT <br />16A <br />MAX AC POWER <br />3800W <br />MODULE SPECS <br />QCELLS NORTH AMERICAQ.PEAK DUO BLK ML-G10+ 405 <br />PMAX <br />405W <br />PTC <br />376.3W <br />ISC <br />11.17A <br />IMP <br />10.83A <br />VOC <br />45.34V <br />VMP <br />37.39V <br />TEMP. COEFF. OF VOC <br />-0.122 <br />POWER <br />OPTIMIZERS <br />RATED INPUT <br />MAX ISC <br />WEIGHTED EFFICIENCY <br />MAX OUTPUT <br />MAX DC <br />SOLAREDGES440 OPTIMIZER <br />440W <br />15A <br />98.6 <br />15A <br />60V <br />AHJ/UTILITY NOTES: <br />SOLAREDGE INVERTER EQUIPPED WITH RSD PER 690.12 <br />INSTALLER NOTES: <br />DESIGNER: TAYLOR BICKFORD <br />NEW PV SYSTEM: 4860 DC / 3800 AC <br />Jose Sandoval <br />2044 S Orange Ave Unit # 2, Santa Ana, CA 92707 <br />APN: 40316211 <br />DATE: 9/10/2024 TIME: 02:37 PM <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE:DESIGNER SIGNATURE: <br />LINE DIAGRAM & <br />DESIGN TABLES <br />006 LD1 <br />JURISDICTION STAMPS: <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />26 <br />This item has been digitally signed <br />and sealed on Oct 09, 2024 <br />2044 S Orange Ave & 2044 <br />S Orange Ave Unit# 211/25/2024