Laserfiche WebLink
EW <br />S <br />N <br />ENGINEERED PLANS COMPLETED BY ENGINEERS IN THE USA <br />VANDERVOORT, DAVID <br />2307 NORTH TOWNER STREET <br />SANTA ANA, CA 92706 <br /> ÀPN/PARCEL NO: 00121406 <br />EXO ENERGY <br />1358 LA MIRADA DRIVE <br />SAN MARCOS, CA 92071 <br />(208) 351-4153 <br />MICHAEL ESPINOZA <br />CSLB: 1063308 <br />B <br />NO <br />R <br />T <br />H <br /> <br />T <br />O <br />W <br />N <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />M <br />E <br />B <br />BB <br />ROOF OBSTRUCTION (TYP.) <br />RAIL (TYP.) <br />MOUNT (TYP.) <br />SEE TABLE BELOW <br />SEE TABLE BELOW FOR <br />ROOF FRAMING SIZE <br />ROOF SECTION 1 <br />TILT: 20À <br />AZIMUTH: 270À <br />ROOF SECTION 2 <br />TILT: 20À <br />AZIMUTH: 180À <br />ROOF SECTION 3 <br />TILT: 20À <br />AZIMUTH: 180À <br />(E) PV SYSTEM <br />ROOF FRAMING 24À ON CENTER <br />48À MAX MOUNT SPACING <br />CHIMNEY (TYP.) <br />(N) PV MODULE EUIPPED <br />W/ 1 MICRO-INVERTER <br />PER MODULE <br />AC UM MSPBI GENINVINVCOM <br />AC <br />SCALE: 3/32À À 1À-0À <br />ROOF <br />FRAMING <br />FRAMING <br />SPACING ROOF TYPE MAX MOUNT <br />SPACING MOUNT MOUNT <br />TYPE <br />EMBEDMENT <br />DEPTH <br />ROOF SECTION 1 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE <br />HOOK FLASHING ROOF MOUNT 2-1/2À <br />ROOF SECTION 2 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE <br />HOOK FLASHING ROOF MOUNT 2-1/2À <br />ROOF SECTION 3 2X4 - TRUSSES 24À CONCRETE W TILE 48À ECOFASTEN TILE <br />HOOK FLASHING ROOF MOUNT 2-1/2À <br />PROPERTY LINE <br />ATTIC RUN CONDUIT <br />EXTERNAL CONDUIT <br />MOUNTING PLAN <br />LEGEND <br />RAIL <br />MOUNT <br />ROOF FRAMING <br />ROOF OBSTRUCTION (TYP.) <br />CHIMNEY <br />ROOF VENT (TYP.) <br />UTILITY METER <br />MAIN SERVICE PANEL <br />AC DISCONNECT <br />DC DISCONNECT <br />AC COMBINER PANEL <br />INVERTER <br />BACKUP INTERFACE <br />BATTERY <br />PRODUCTION METER <br />SUBPANEL <br />UNCTION BOX <br />SATELLITE DISH <br />COM <br />PM <br />B <br />B <br />UM <br />MSP <br />INV <br />DC <br />BI <br />AC <br />SUB <br />GAS METER GM <br />I SYSTEM CONTROLLER I <br />LOAD CENTER LC <br />METAL SEAMS <br />MOUNTING PLAN NOTES: <br />1. VERIFY ALL OBSTRUCTIONS AND DIMENSIONS IN THE FIELD. <br />2. PROVIDE RAIL SPLICES AS REUIRED BY MANUFACTURERÀS GUIDELINES. <br />3. NO SIGNIFICANT SHADING WILL RESULT FROM EXISTING ROOF OBSTRUCTIONS. <br />4. PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ATTIC, PLUMBING, <br />FURNACE OR WATER HEATER VENTS <br />5. ACTUAL ROOF CONDITIONS AND ROOF FRAMING (OR SEAM)LOCATIONS MAY <br />VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND <br />ENGINEERED SPANS FOR ATTACHMENTS <br />CANTILEVER NOTES: <br />1. CANTILEVER (OVERHANG) LENGTHS CAN BE UP TO 33 OF THE <br />SPAN LENGTH. <br />2. THE CANTILEVER IS DEFINED AS THE DISTANCE FROM THE <br />CENTER OF THE MOUNT TO THE EDGE OF THE RAIL <br />PV-4 <br />DATE:8/9/2024 <br />MOUNTING PLAN <br />swyssling@wysslingconsulting.com <br />(201) 874-3483 <br />DESIGN ENGINEER <br />SOLAR COMPANY/CLIENT <br />76 N. MEADOWBROOK DRIVE <br />ALPINE, UTAH 84004 <br />2307 N Towner St <br />8/23/2024