Laserfiche WebLink
ATTACHMENT <br />LAYOUT <br />5 <br />PV SYSTEM <br />AS INDICATED <br />AUGUST 09, 2023 <br />DAVID VANDERVOORT <br />2307 N TOWNER ST, <br />SANTA ANA, CA 92706 <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />CONTRACTOR <br />STRUCTURAL STAMPROOF <br />PITCH <br />ROOFING <br />TYPE <br />ATTACHMENT <br />TYPE <br />FRAMING <br />TYPE <br />FRAMING <br />SIZE <br />PENETRATION <br />PATTERN <br />20° <br />RACKING <br />TYPE <br />MAX <br />PENETRATION <br />SPACING <br />ROOFING <br />LAYERS <br />WIND SPEED 110 MPH EXPOSURE C <br />LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE <br />SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. <br />MODULE WEIGHT (LBS) <br /># OF MODULES <br />TOTAL MODULE WEIGHT (LBS) <br />RACK WEIGHT (LBS) <br />TOTAL SYSTEM WEIGHT (LBS) <br /># OF STANDOFFS <br />LOADING PER STANDOFF (LBS) <br />TOTAL MODULE AREA (SQ.FT.) <br />LOADING (PSF) <br />WEIGHT LOAD CALCULATION INDEX <br />ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER <br />SURFACE IS FACED WITH FELT PAPER <br />TOTAL ROOF AREA (Sq. FT) <br />% OF COVERED AREA <br />PV MODULE MODEL # <br />MICROINVERTER WEIGHT (LBS) <br />18 <br />Roof 1 1 Layer M Concrete Tile EcoFasten Truss Stacked 48"2"X4" @ 24" O.C <br />2''X6'' Blocking <br />SOLAR MODULE <br />ROOF 1,2 <br />ASCE 7-16 <br />Max 3.5'' <br />48.5 <br />Q.PEAK DUO BLK ML-G10+ 400 <br />47 <br />378 <br />4610 <br />873 <br />175 <br />43 <br />1090 <br />23.2 <br />2.88 <br />8.2 <br />20°Roof 2 1 Layer Comp Shingle Ironridge XR10 Truss Stacked 48"2"X4" @ 24" O.C <br />PART TABLE <br />P/N DESCRIPTION <br />004085M FLASHLOC COMP KIT MILL, 20 PACK <br />004085D FLASHLOC COMP KIT DARK, 20 PACK <br />SS LAG BOLT <br />W/ SS EPDM BONDED WASHER <br />SS SERRATED T-BOLT <br />SS SERRATED FLANGE NUT <br />FLASHLOC BASE <br />MILL OR DARK <br />33 <br />21 4" <br />31 2" <br />67 8" <br />Unirac Flashloc Kit <br />MIN 2.5" EMBEDMENT <br />RACKING RAIL <br />ATTACHMENT <br />ROOF FRAMING <br />5/16" X 4.0" <br />Ecofasten Universal Tile Hook <br />ATTACHMENT DETAILS <br />ROOF SHEETING <br />WATERPROOF <br />MEMBRAIN ROOF TILE <br />ECOFASTEN RAIL <br />5/16"x4.0" LAG BOLT <br />WITH 2 1/2"MIN <br />THREAS PENETRATION <br />ECOFASTEN'S CLICKFIT <br />UNIVERSAL TILE HOOK <br />TILE HOOK FLASHING <br />TILE HOOK ADDENDUMSOLAR MODULE <br />48''24'' <br />Roof 2 <br />Roof 2 <br />Signed 08/09/2023 <br />2307 N Towner St - <br />2017896310/18/2023