Laserfiche WebLink
Wind Loading Continued… <br />Components and Cladding, Roofs <br />Applicable Roof Slope Angle = <br />a = 3.00 ft. <br />Tributary Pressure <br />Area All 1 2 2'3 3'--- <br />Item (ft2)(psf)(psf)(psf)(psf)(psf)(psf)--- <br />Purlin/Joist 385 -----16.93 -22.57 -22.57 -16.93 -16.93 ---- <br />Panel 4 -----28.22 -39.50 -39.50 -46.27 -46.27 ---- <br />Fastener 4 -----28.22 -39.50 -39.50 -46.27 -46.27 ---- <br />Purlin/Joist 385 ---------------------------- <br />Panel 4 ---------------------------- <br />Fastener 4 ---------------------------- <br />Components and Cladding, Below-Eave Canopy <br />Tributary Pressure <br />Area Total <br />Item (ft2)(psf)hc ≤ 7 ft Otherwise hc ≥ 12.6 ft <br />385 16.00 -16.00 -16.00 -16.00 <br />4 16.00 -16.00 -16.00 -16.00 <br />4 16.00 -16.00 -16.00 -16.00 <br />Main Wind Force Resisting Systems (Transverse Wind Direction) <br />Applicable Roof Slope Angle = <br />a = ---- <br />Transverse Wind Direction <br />Item W1R W1L W2R W2L W3R W3L W4R W4L <br />C1:0.75 -0.75 0.75 -0.75 0.75 -0.75 0.75 -0.75 <br />Load, (psf)8.46 -8.46 8.46 -8.46 8.46 -8.46 8.46 -8.46 <br />C2:1.02 0.26 -0.94 -0.09 -0.43 -1.02 -0.94 -0.51 <br />Load, (psf)11.51 2.88 -10.55 -0.96 -4.80 -11.51 -10.55 -5.76 <br />C3:0.26 1.02 -0.09 -0.94 -1.02 -0.43 -0.51 -0.94 <br />Wind W1R W1L Load, (psf)2.88 11.51 -0.96 -10.55 -11.51 -4.80 -5.76 -10.55 <br />W3R W3L C4:-0.75 0.75 -0.75 0.75 -0.75 0.75 -0.75 0.75 <br />Load, (psf)-8.46 8.46 -8.46 8.46 -8.46 8.46 -8.46 8.46 <br />C5:-0.75 -0.75 -0.75 -0.75 -0.75 -0.75 -0.75 -0.75 <br />Load, (psf)-8.46 -8.46 -8.46 -8.46 -8.46 -8.46 -8.46 -8.46 <br />C6:-0.75 -0.75 -0.75 -0.75 -0.75 -0.75 -0.75 -0.75 <br />Load, (psf)-8.46 -8.46 -8.46 -8.46 -8.46 -8.46 -8.46 -8.46 <br />Wind W2R W2L W1R &W1L &W2R &W2L & <br />W4R W4L Item W3R W3L W4R W4L <br />C1E:---------------- <br />Load, (psf)---------------- <br />C2E:---------------- <br />Load, (psf)---------------- <br />C3E:---------------- <br />Load, (psf)---------------- <br />C4E:---------------- <br />Load, (psf)---------------- <br /> he : Average Eave <br /> Height <br /> hc : Average <br /> Canopy <br /> Elevation <br />Edge Zone Pressure Coefficients <br />Suction in Zones <br />7.45 deg <br />7.45 deg <br />Values Below are for the Overhang Portion of the Roof <br />Uplift Total (psf) <br />For Various Canopy Elevations <br />Purlin / Joist <br />Panel <br />Fastener <br />InternalSuction <br />Wind Direction <br />InternalPressure <br />Wind Direction <br />10 <br />Wind Loading Continued… <br />Components and Cladding, Roofs <br />Applicable Roof Slope Angle = <br />a = 3.00 ft. <br />Tributary <br />Area P1 P2 P3 1 2 3 --- <br />Item (ft2)(psf)(psf)(psf)(psf)(psf)(psf)--- <br />Purlin/Joist 385 16.00 16.00 16.00 -16.28 -16.28 -16.28 ---- <br />Panel 4 16.00 22.99 30.65 -16.28 -24.90 -48.84 ---- <br />Fastener 4 16.00 22.99 30.65 -16.28 -24.90 -48.84 ---- <br />Purlin/Joist 385 ---------------------------- <br />Panel 4 ---------------------------- <br />Fastener 4 ---------------------------- <br />Suction in Zones <br />7.45 deg <br />Values Below are for the Overhang Portion of the Roof <br />Pressure in Zones <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024