Laserfiche WebLink
MECHANICAL ATTACHMENT PART TO <br />BE DETERMINED. MANUFACTURED BY <br />OTHERS <br />NOTE: <br />THIS DETAIL IS GENERIC IN NATURE AND IS <br />INTENDED ONLY TO SHOW TYPICAL <br />MECHANICAL ATTACHMENT ASSEMBLY <br />LOCATIONS. REFER TO INDIVIDUAL ARRAY <br />LAYOUTS FOR REQUIRED LOCATIONS. <br />MECHANICAL ATTACHMENT <br />SOUTH EDGE APPLICATION <br />CENTERED BELOW MODULES <br />MECHANICAL ATTACHMENT <br />SOUTH EDGE APPLICATION <br />CENTERED BETWEEN MODULES <br />MECHANICAL ATTACHMENT <br />INTERIOR APPLICATION <br />CENTERED BETWEEN MODULES <br />MECHANICAL ATTACHMENT <br />NORTH EDGE APPLICATION <br />CENTERED BETWEEN MODULES <br />MECHANICAL ATTACHMENT <br />NORTH EDGE APPLICATION <br />CENTERED BELOW MODULES <br />MECHANICAL ATTACHMENT <br />INTERIOR APPLICATION <br />CENTERED BELOW MODULES <br />MA STRUT <br />TRANSPARENT PV <br />SOLAR MODULE <br />MECHANICAL ATTACHMENT <br />MA STRUT <br />3/8, 304 S.S. <br />FLAT WASHER <br />3/8-16, 304 S.S. HARDWARE <br />1.25" LENGTH BOLT <br />3/8-16, 304 S.S. <br />HEX FLANGE NUT <br />M6, HARDWARE <br />16MM LENGTH BOLT <br />STRUT BRACKET <br />U-BRACKET <br />RE <br />V <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />PR <br />E <br />P <br />CH <br />E <br />C <br />K <br />DA <br />T <br />E <br />PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. <br /> C <br />SCALE: <br />0"1/2"1"2" <br />ORIGINAL SIZE 36"X24" <br />SHEET SIZE ARCH "D" <br />1600 OSGOOD ST. SUITE 2023 <br />NORTH ANDOVER, MA 01845 <br />TEL: 978.688.4900 <br />www.panelclaw.com <br />STAMP: <br />PREPARED FOR: <br />PROJECT: <br />LOCATION: <br />REVISION:SHEET: <br />8 7 6 5 4 3 2 1 <br />8 7 6 5 4 3 2 1 <br />SHEET TITLE: <br />A <br />B <br />C <br />D <br />A <br />B <br />C <br />D <br />RACKING CONSTRUCTION SET <br />SCALE: <br />MECHANICAL ATTACHMENT DETAIL B <br />N.T.S.SCALE: <br />MECHANICAL ATTACHMENT DETAIL C <br />N.T.S. <br />SCALE: <br />MECHANICAL ATTACHMENTLOCATION DETAIL A <br />N.T.S. <br />MECHANICAL ATTACHMENT <br />WORST-CASE SERVICE LOAD (LB) <br />1.HORIZONTAL LOAD H MAY ACT IN ANY DIRECTION <br />2.WORKING LOADS = ALLOWABLE LOADS (i.e. NON-FACTORED) <br />HORIZONTAL (H)VERTICAL (V) <br />WIND SEISMIC WIND <br />MAXIMUM ALLOWABLE LOAD (LB) <br />HORIZONTAL (H)VERTICAL (V) <br />RACKING CONSTRUCTION SET <br />Messi <br />Samueli Academy Bldg B <br />1909 North Fairview Street, Santa <br />Ana, CA, USA <br />1 PC-9 <br />MECHANICAL <br />ATTACHMENT DETAIL <br />23.05.22.1 v3.0.9404.6.1 <br />1 <br />AF <br />C <br /> <br />s <br />e <br />t <br />SM <br />20 <br />2 <br />3 <br />- <br />0 <br />6 <br />- <br />2 <br />6 <br />0 <br />Re <br />v <br />0 <br />SM <br />20 <br />2 <br />3 <br />- <br />0 <br />6 <br />- <br />2 <br />1 <br />89 42 386 <br />650 525 <br />APPROVED FOR CONSTRUCTION <br />PC-9 <br />PC-9 PC-9 <br />_________________________ <br />nature <br />_________________________________________________ <br />_____________________________________________________________ <br />_________________________ <br />nature <br />________________________________________________ <br />_____________________________________________________________ <br />DRAWINGS ARE PREPARED BY OTHERS & REVIEWED <br />ONLY FOR ADEQUATE STRUCTURAL ELEMETNS BY <br />ELIE SAYEGH, PE AT MOTIVE ENERGY. <br />02/15/2024 <br />U-ANCHOR 2400 MECHANICAL <br />ATTACHMENT <br />11.75"4.83" <br />2.2 in <br />3.25 in <br />REFER TO PROCEEDING ROOF FRAMING PLAN SHEET FOR FASTERNER SIZE <br />& QUANTITY <br />REFER TO ROOF FRAMING PLAN FOR ADDITIONAL INFORMATION <br />REGARDING THE ROOF MEMBRANE <br />8-1/4" DIAMTER HOLES <br />2 <br />2 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024