My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fairview St
>
1901 N Fairview St Bldg# B
>
1901 N Fairview St & Bldg A, B, C, F & 1919 N Fairview St Bldg E - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 2:00:13 AM
Creation date
6/6/2025 1:22:19 PM
Metadata
Fields
Template:
Plan
Permit Number
20180424
20180427
20180439
20180441
20180444
101116031
101119651
Full Address
1901 N Fairview St Bldg# B
1901 N Fairview St Bldg# C
1919 N Fairview St Bldg# E
1901 N Fairview St Bldg# F
1901 N Fairview St
Street Number
1901
1901
1919
1901
1901
Street Direction
N
N
N
N
N
Street Name
Fairview
Fairview
Fairview
Fairview
Fairview
Street Suffix
St
St
St
St
St
Building Number
B
C
E
F
Permit Number (Not in SAPIN)
2018049
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
694
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
5.0 Design Loads - Wind (Cont.): <br />5.1.2 Global Wind Shear Summary Table: <br /> <br />Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The <br />table below provides the mechanical attachment requirements for each sub-array within this project. <br /> <br /> Applied Load Resisting Load Code Check <br />Sub- <br />Array <br />Name <br />FL-D = <br />Wind <br />Uplift <br />(lbs.) <br />FD = <br />Wind <br />Drag <br />(lbs.) <br />DL = <br />Total <br />Dead <br />Load <br />(lbs.) <br />Maximum <br />Allowable <br />Mechanical <br />Attachment <br />Strength (lbs.) <br />Total MA <br />Capacity <br />(lbs.) <br />Check <br />Calculated <br />Factor of <br />Safety* <br />Check <br />1.1 2,686 772 3,692 650 4,550 3.76 OK <br />1.2 6,059 1,781 5,207 650 13,650 3.79 OK <br />Total:8,745 lbs.2,553 lbs.8,899 18,200 lbs. <br />Table 5.2 Summary of Mechanical Attachment Requirements <br />* Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE7 equation 7, BACK <br />CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(((.6)WIND DRAG /FRICTION)+(.6)WIND <br />UPLIFT) <br />06/01/2023 <br />APPROVED FOR CONSTRUCTION <br />10 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br /> (978) 688.4900 - www.panelclaw.com <br />P- 36 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.