Laserfiche WebLink
6.0 Design Loads - Downward (Cont.): <br />6.2 Racking Dimensions for Point Loads (Cont.): <br />Fig. 6.2 Section A-A <br />6.3 Point Load Summary:Notes: <br />DLsys = 99 lbs./module -Base 2 repeat for larger width arrays. <br />Total DL = (Varies on location and ballast quantity) <br />SLm = 0 lbs./module <br />WLin (no snow) = 623 lbs./module <br />WLin (with snow) = 208 lbs./module <br /> <br /> <br />Max Total Load Per Base (lbs.) <br />load combinations (ASD) <br />Location Base <br />DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) <br />South 1 47 141 71 <br />Interior 2 118 304 164 <br />2nd From North 3 92 279 139 <br />North 4 91 185 115 <br />Table 6.1-A Max Total Load per Base (lbs.) <br /> <br />Max Contact Pressure Table Per Base (psi) <br />load combinations (ASD)# of <br />Pads <br />Location Base <br />DL + Snow DL + 0.6 X Wlin DL + 0.75 X SLm + 0.75(0.6 X WLin) <br />South 1 3 8 4 <br />Interior 2 6 17 9 <br />2nd From North 3 5 15 8 <br />2 <br />North 4 5 10 6 <br />South 1 1 4 2 <br />Interior 2 3 8 4 <br />2nd From North 3 2 8 4 <br />4 <br />North 4 2 5 3 <br />Table 6.1-B Max Point Load Summary (psi) <br />06/26/2023 <br />APPROVED FOR CONSTRUCTION <br />12 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br /> (978) 688.4900 - www.panelclaw.comP-38 <br />1901 N Fairview St & Bldg A, B, <br />C, F & 1919 N Fairview St Bldg E <br />4/11/2024