INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS SHALL BE TESTED AS SPECIFIED IN <br />SECTION 803.1.3. <br />803.1.1 INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED FOR FIRE <br />PERFORMANCE AND SMOKE DEVELOPMENT IN ACCORDANCE WITH ASTM E 84 OR UL 723. SUCH <br />INTERIOR FINISH MATERIALS SHALL BE GROUPED IN THE FOLLOWING CLASSES IN ACCORDANCE <br />WITH THEIR FLAME SPREAD AND SMOKE-DEVELOPED INDEXES. <br />CLASS A: FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450. <br />CLASS B: FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450. <br />CLASS C: FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450. <br />EXCEPTION: MATERIALS TESTED IN ACCORDANCE WITH SECTION 803.1.2. <br />SPRINKLERED <br />GROUP EXIT STAIRWAYS, EXIT RAMPS, CORRIDORS & EXIT ENCLOSED SPACES <br />& EXIT PASSAGEWAYS ENCLOSURES <br />B B C C <br />REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES SHALL BE BASED UPON SPACES <br />ENCLOSED BY PARTITIONS. WHERE A FIRE RESISTANCE RATING IS REQUIRED FOR STRUCTURAL <br />ELEMENTS, THE ENCLOSING PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE CEILING. <br />PARTITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED ENCLOSING SPACES AND <br />THE ROOM OR SPACES ON BOTH SIDES SHALL BE CONSIDERED ONE. <br />FINISH MATERIALS FLAME SPREAD RATING <br />REFER TO A3.03 FOR DETAILS <br />FLOORING <br />CPT-2 CARPET <br />CT-1 CERAMIC TILE <br />LWP LUXURY WOOD-LOOK PLANK <br />BASE <br />VCB-1 VINYL COVE BASE <br />VT-1 VINYL COMPOSITION TILE <br />WALLS <br />GYP. GYPSUM WALL BOARD <br />WC-1 CERAMIC WALL TILE <br />PAINT PAINT FINISH <br />CEILING <br />ACT ACOUSTICAL CEILING TILE <br />ABBREVIATIONS <br />FF FACTORY FINISH <br />FINISH MATERIAL LEGEND <br />7' <br /> <br />- <br /> <br />0 <br />" <br />FINISHED <br />FLOOR <br />D <br />DOOR: S.C. W.D. <br />DOOR OR HOLLOW <br />METAL <br />C <br />2"2" <br />2" <br />7' <br /> <br />- <br /> <br />0 <br />" <br />DOOR: S.C. W.D. <br />DOOR WITH 1/4" <br />TEMPERED GLAZING <br />2"2" <br />2" <br />3' - 0"3' - 0" <br />A <br />EXISTING DOOR TO <br />REMAIN <br />DOOR TYPES <br />B <br />EXISTING DOOR TO BE <br />DEMOLISHED <br />10 <br />" <br />HARDWARE SET - 1 <br />PASSAGE LOCKSET SET : <br />1 1/2 PAIR BUTT HINGES <br />1 EA. LEVER TYPE PASSAGE LOCKSET <br />1 EA. WALL STOP <br />3 EA. SILENCER <br />HARDWARE SET - 2 <br />PRIVACY LOCKSET SET : <br />1 1/2 PAIR BUTT HINGES <br />1 EA. LEVER TYPE PRIVACY LOCKSET <br />1 EA. WALL STOP <br />3 EA. SILENCER <br />HARDWARE SET - 3 <br />STORE ROOM LOCKSET SET : <br />1 1/2 PAIR BUTT HINGES <br />1 EA. LEVER TYPE STORE ROOM LOCKSET <br />1 EA. WALL STOP <br />3 EA. SILENCER <br />HARDWARE SET - 4 <br />TO MATCH (E) <br />DOOR HARDWARE <br />A <br />AL ALUMINUM <br />ANZ ANODIZED <br />C <br />CAA CLEAR ANOD. ALUM. <br />CL CLEAR <br />CR CARD READER <br />E <br />E EXISTING <br />EH EMBOSSED HARDBOARD <br />F <br />FP FLUSH PANEL <br />FS FACTORY STANDARD <br />G <br />GL TEMP. GLASS <br />H <br />HM HOLLOW METAL (RATED) <br />L <br />LQ LACQUERED <br />M <br />ME MATCH EXISTING <br />MH MAGNETIC HOLD OPEN <br />MTL METAL <br />MIN MINUTES <br />N <br />NR NON RATED <br />P <br />PB PANIC BAR <br />PF PREFINISHED <br />PL PLASTIC LAMINATE <br />PR PAIR <br />PT PAINT <br />PWC POWDER COAT <br />S <br />STN STAINED <br />SC SOLID CORE <br />STL STEEL <br />T <br />T TEMPERED <br />V <br />VAR VARNISH <br />VEN VENEER <br />DOOR ABBREVIATIONS <br />1. DOORS: (N) INTERIOR DOORS, FRAMES & HARDWARE TO MATCH (E) BLD'G <br />STANDARD. G.C. TO V.I.F. PRIOR TO BID & ORDERING OF MATERIALS <br />2. WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH C.B.C. SECTION <br />1010.1 AND TITLE 24, <br />3. DOOR HARDWARE TO BE LEVER TYPE TO MEET ACCESSIBILITY REQUIREMENTS. ALL <br />REQUIRED EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF <br />A KEY OR SPECIAL KNOWLEDGE OR EFFORT. MAXIMUM EFFORT TO OPERATE DOORS <br />SHALL NOT EXCEED 5 LBS. FOR EXTERIOR DOORS AND INTERIOR DOORS. <br />4. DOORS MUST HAVE A CLEAR SPACE OF AT LEAST 60" IN SIDE WHERE DOOR SWINGS <br />X 60" WIDE (18" BEYOND DOOR STRIKE EDGE @ INTERIOR DOOR. <br />5. 20 MIN. RATED FIRE DOOR & FRAME ASSEMBLY PER C.B.C W/ SMOKE AND DRAFT <br />CONTROL ASSEMBLY. <br />6. GLAZING IN OR ADJACENT TO DOORS SHALL MEET REQUIREMENTS OF (C.B.C. SEC <br />2406.4). ALL WINDOWS WITHIN 24" OF INTERIOR DOOR ARE TO BE TEMPERED GLASS, <br />TYP. <br />7. PROVIDE SMOOTH UNINTERRUPTED SURFACE ON PUSH SIDE OF DOORS WITHIN 10" <br />OF THE GROUND. <br />8. FRAMELESS DOOR W/ LAMINATED GLASS SIMILAR TO "HERCULITE DOOR SYSTEM" <br />PROVIDE PIVOT HARDWARE & DOOR PULL AS REQUIRED. <br />10. MINIMUM DOOR SIZE PROVIDES A CLEAR OPENING OF 32" WHILE DOOR IS IN 90 <br />DEGREE OPEN POSITION. <br />11. OPENING HARDWARE IS CENTERED BETWEEN 34" AND 40" ABOVE FINISH FLOOR. <br />12. DOOR CLOSERS, IF PRESENT, SHALL BE ADJUSTED SO THAT FROM AN OPEN <br />POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION <br />OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. <br />13. ALL LOCKSETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE WITH THE <br />LANDLORD REQUIREMENTS. CODES AND/OR KEYS ARE TO BE DELIVERED TO <br />LANDLORD PROPERLY TESTED AND/OR TAGGED. THE NUMBER OF MASTER AND <br />PASS KEYS SHALL BE COORDINATED WITH THE LANDLORD. <br />14. CONTRACTOR SHALL PROVIDE DUST COVERS AT ALL STRIKE PLATES. <br />15. ALL FASTENERS SHALL MATCH THE HARDWARE MATERIAL AND FINISH. <br />16. GC TO REMOVE ALL EXISTING DOOR HARDWARE ITEMS THAT DO NOT COMPLY WITH <br />CURRENT DISABLED PROVISIONS AND REPLACE THEM WITH CONFORMING ITEMS TO <br />THE SATISFACTION OF THE BUILDING AUTHORITY. <br />17. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED NOT LESS THAN <br />34" NOR MORE THAN 44" HIGH AND SHALL BE OPERABLE WITH A SINGLE EFFORT NOT <br />REQUIRING GRASPING OF THE OPENING HARDWARE. <br />18. THRESHOLDS SHALL NOT BE GREATER THAN 1/2" IN TOTAL HEIGHT WITH THE <br />LEADING EDGES BEVELED OR SLOPED AT AN ANGLE NOT EXCEEDING 45 DEGREES SO <br />THAT NO SINGLE VERTICAL CHANGE OF ELEVATION EXCEEDS 1/4". THE BOTTOM 10" <br />OF ALL DOORS (EXCEPT AUTOMATIC AND SLIDING) SHALL HAVE A SMOOTH <br />UNINTERRUPTED SURFACE. NARROW FRAME DOORS SHALL BE EQUIPPED WITH A 10" <br />HIGH SMOOTH PANEL ON THE PUSH SIDE OF THE DOOR. <br />19. GC TO VERIFY THE THICKNESS OF FLOOR FINISH PRIOR TO UNDERCUTTING THE <br />DOOR. ALL NEW DOORS TO HAVE 1/4" MAXIMUM UNDERCUT, U.N.O. <br />20. INSTALL DOOR IN FRAME WITH 1/8" MAX TOLERANCE AT HEAD, HINGES AND STRIKE <br />JAMB. ALL REUSED DOORS AND HARDWARE TO BE FULLY INSPECTED FOR <br />SOUNDNESS AND FUNCTION. REUSABLE COMPONENTS SHALL BE CLEANED, OILED , <br />PATCHED, REFINISHED AS REQUIRED. VERIFY DOOR LEVER IS ACCESSIBLE TYPE <br />LEVER OR PULL. <br />21. GLAZING IN THE FOLLOWING LOCATIONS MUST BE TEMPERED OR BE SAFETY <br />GLAZING: <br />A. IN ALL SWINGING DOORS, <br />B. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES, <br />C. IN FIXED AND OPERABLE PANELS ADJACENT TO A DOOR WHERE THE <br />NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF <br />EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE <br />THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE <br />WALKING SURFACE, <br />D. IN FIXED OR OPERABLE PANELS, OTHER THAN IN THOSE LOCATIONS <br />DESCRIBED ABOVE, WHICH MEETS ALL OF THE FOLLOWING CONDITIONS <br />WHERE THE EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 <br />SQUARE FEET, THE EXPOSED BOTTOM EDGE IS LESS THAN 18" ABOVE THE <br />FLOOR, THE EXPOSED TOP EDGE IS GREATER THAN 36" ABOVE THE FLOOR <br />AND ONE OR MORE WALKING SURFACES ARE WITHIN 36" HORIZONTALLY OF <br />THE PLANE OF THE GLAZING. <br />22. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR <br />GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH <br />SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING <br />HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH <br />OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. <br />CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. §11B-404.2.10 <br />DOOR GENERAL NOTES <br />CONDITION A <br />DOORS SHOWN ADJACENT TO A PERPENDICULAR <br />WALL OR OTHER FIXED OBSTRUCTION <br />CONDITION B <br />OTHER LOCATIONS SHALL BE ON CENTERLINE OF <br />ROOM UNLESS SPECIFICALLY DIMENSIONED <br />TYPICAL DOOR CLEARANCES <br />TYPICAL DOOR LOCATION <br />24" <br />1' - 6" <br />1' - 0" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />PUBLIC AREA DOORS <br />CLEAR AND LEVEL <br />FLOOR SPACE <br />AT <br />INTERIOR <br />AT <br />EXTERIOR <br />(6" PREFERRED) <br />4" TYP. <br />PUBLIC SPACES: 4" MIN. <br />OPENING <br />DOOR <br />EQ EQ <br />FLOOR TRANSITION <br />STRIP PER FINISH <br />SCHEDULE <br />DOOR PER SCHEDULE <br />FLOOR PER SCHEDULE <br />~1 <br />/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br />NOTE: <br />THRESHOLD SHALL BE NO MORE <br />THAN 1/2" HIGH REBELLED AT 2 <br />HORIZONTAL TO 1 VERTICAL TO A <br />VERTICAL MAX. OF 1/4". PER CBC <br />11B-404.2.5 <br />DOOR PER <br />SCHEDULE <br />PE <br />R <br /> <br />W <br />A <br />L <br />L <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />DOOR PER <br />SCHEDULE <br />PE <br />R <br /> <br />W <br />A <br />L <br />L <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A RCHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S De Lacey Ave. Unit #210 <br />Pasadena, CA 91105 <br />(760) 673-6837 <br />(760) 673-2550 <br />info@369architects.com <br />As indicated <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />2 <br />5 <br />: <br />0 <br />6 <br /> <br />P <br />M <br />FINISH & DOOR <br />SCHEDULES <br />1414 W EDINGER AVE, SANTA <br />ANA, CA 92704 <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />Checker <br />J.F. <br />03/27/25 <br />24001 <br />ROOM # ROOM NAME FLOOR BASE <br />WALL <br />MATERIAL <br />WALL <br />FINISH <br />CEILING <br />MATERIAL <br />CEILING <br />FINISH <br />CEILING <br />HEIGHT REMARKS <br />120 WAITING AREA CT-1 VCB GYP. PAINT ACT FF 10' - 0" CPT-1 @ WALK-OFF <br />121 PLAY AREA CPT-2 VCB GYP. PAINT ACT FF 10' - 0" <br />122 OFFICE/IT LWP VCB GYP. PAINT ACT FF 10' - 0" <br />123 TOILET CT-1 VCB GYP. PAINT GYP. PAINT 9' - 0" WC-1 @ WET WALL <br />124 TOILET CT-1 VCB GYP. PAINT GYP. PAINT 9' - 0" WC-1 @ WET WALL <br />125 RECEPTION CT-1 VCB GYP. PAINT ACT FF 10' - 0" <br />126 LAB LWP VCB GYP. PAINT ACT FF 10' - 0" <br />127 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />128 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />129 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />130 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />131 UTILITY VT-1 VCB GYP. PAINT ACT FF 10' - 0" <br />132 LOUNGE LWP VCB GYP. PAINT ACT FF 10' - 0" <br />133 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />134 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />135 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />136 EXAM ROOM LWP VCB GYP. PAINT ACT FF 10' - 0" <br />137 CORRIDOR CT-1 VCB GYP. PAINT ACT FF 10' - 0" <br />138 COATS CT-1 VCB GYP. PAINT GYP. PAINT 9' - 0" <br />ROOM FINISH SCHEDULE <br />SYM TYPE (N) or (E) DESCRIPTION WIDTH HEIGHT THICKNESS <br />DOOR <br />MATERIAL <br />DOOR <br />FINISH <br />FRAME <br />SIZE <br />FRAME <br />MATERIAL <br />GLASS <br />TYPE <br />HARDWARE <br />TYPE COMMENTS <br />1 A EXISTING STOREFRONT GLASS DOOR ENTRY 6' - 0" 7' - 0" 0' - 2" EXISTING STOREFRONT DOOR TO REMAIN' <br />2 D NEW (N) HOLLOW METAL DOOR 3' - 0" 7' - 0" 0' - 1 3/4" Stainless Steel 2" MTL. 2 <br />3 C NEW (N) GLASS DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. TEMP. 1 NEW GLASS DOOR <br />4 C NEW (N) GLASS DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. TEMP. 1 NEW GLASS DOOR <br />5 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 2 <br />6 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 2 <br />7 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 1 <br />8 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 1 <br />9 D NEW (N) SINGLE FLUSH DOOR 2' - 6" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 3 PROVIDE KNURLED LEVER HANDLESS, CLOSER <br />10 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 1 PROVIDE CLOSER <br />11 D NEW (N) SINGLE FLUSH DOOR 3' - 0" 7' - 0" 0' - 1 3/4" WD S & V 2" MTL. 3 PROVIDE KNURLED LEVER HANDLESS, CLOSER <br />12 B EXISTING (E) DOOR AND FRAME TO BE DEMO 3' - 0" 6' - 8" 0' - 2" <br />13 B EXISTING (E) DOOR AND FRAME TO BE DEMO 3' - 6" 6' - 8" 0' - 2" <br />DOOR SCHEDULE <br />3" = 1'-0"1 DOOR THRESHOLD DETAIL <br />3" = 1'-0"2 DOOR JAMB DETAIL @ HINGE <br />3" = 1'-0"3 DOOR JAMB DETAIL @ STRIKE <br />3" = 1'-0"4 DOOR HEAD W/ CLOSER DETAIL <br />DOOR DETAILS <br />S & V = STAINED AND VARNISH. RIFT CUT, RED OAK, LIGHT STAIN (TBD) / CLEAR SATIN FINISH <br />No. Description Date <br />1 PLAN CHECK 1 02/06/25