My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1414 W Edinger Ave - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1414 W Edinger Ave
>
1414 W Edinger Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:58 PM
Creation date
6/6/2025 1:22:21 PM
Metadata
Fields
Template:
Plan
Permit Number
20184135
30147841
40139567
101121037
Full Address
1414 W Edinger Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DAMPER SPECIFICATIONS:AND DH1851 DUCT SMOKE DETECTOR <br />MOUNTED IN A SLEEVE WITH 5800-MB2 ELECTRIC ACTUATOR <br />POTTORFF SERIES 5000 COMBINATION FIRE/SMOKE DAMPER <br />DAMPER <br />SMOKE DETECTOR. <br />ESL609 DUCT MOUNTED <br />COMBINATION FIRE/SMOKE <br />SERIES 5000 <br />DAMPER <br />COMBINATION FIRE/SMOKE <br />ACCESS DOOR <br />MOTOR ACTUATOR. <br />5800 MB2 <br />16" MAX. <br />7" STD. <br />EF <br />- <br />E <br />DISC. SW. <br />MOTION SENSOR <br />E <br />E <br />C.B. <br />SEE SCHEDULE <br />BACKDRAFT DAMPER <br />CEILING CEILING GRILLE <br />EXHAUST FAN <br />6" HIGH CURBCANT STRIP <br />PLATFORM <br />BY G.C. <br />LEVEL <br />A/C CONTRACTOR <br />COVER BY <br />ROOFING <br />SHEET METAL <br />ISOLATOR <br />VIBRATION <br />9 <br />NOT TO SCALE <br />SCALE 1 <br />NOT TO SCALE <br />SCALE <br />OPENING TO BE SINGLE HEADER FRAMING FOR WOOD OR STEEL. <br />WOOD FRAMED OPENINGS MUST BE LINED WITH MINIMUM 5/8" TYPE X <br />GYP. BOARD. LINING NOT REQUIRED AT STEEL STUD, CONCRETE OR <br />MASONRY. SUGGESTED CLEARANCE BETWEEN SLEEVE AND OPENING <br />1/8" FOR EACH 12" DAMPER WIDTH AND HEIGHT FOR EXPANSION. <br />DAMPER TO BE HELD IN PLACE BY RETAINING ANGLES ATTACHED TO <br />SLEEVE ON BOTH SIDES OF PARTITION, AND AROUND ENTIRE <br />PERIMETER OF THE SLEEVE. ANGLES TO BE MIN. 16 GA. 1 1/2" X 1 1/2" <br />OR LARGER AS REQUIRED TO PROVIDE A MIN. 1" OVERLAP OF THE <br />OPENING. ANGLES MAY BE MITERED, BUTTED, OR OVERLAPPED AT <br />THE CORNERS. ATTACH ANGLES TO THE SLEEVE ( NOT THE PARTITION <br />) WITH SHEET METAL SCREWS, BOLTS OR WELDS AS PER <br />MANUFACTURERS INSTRUCTIONS. CONNECT DUCT TO SLEEVE WITH <br />"S" TYPE SLIP CONNEC- TION. DO NOT USE MECHANICAL FASTENERS. <br />10NOT TO SCALE <br />SCALE <br />NOT TO SCALE <br />SCALE 2 NOT TO SCALE <br />SCALE 3 <br />5NOT TO SCALE <br />SCALE 6NOT TO SCALE <br />SCALE 7NOT TO SCALE <br />SCALE <br />SCALE 11NOT TO SCALE <br />SCALE <br />LINED DUCT <br />WRAPPED DUCT <br />EARTHQUAKE <br />STABILIZER <br />RIBBED <br />NEOPRENE PAD <br />2) FOR ANCHORAGE SEE SEISMIC RESTRAINT SCHEDULE. <br />NOTES: <br />NEOPRENE <br />WASHER <br />1) ISOLATOR IS TYPICAL FOR: <br />3) DESIGN STATIC DEFLECTION IS 1.0" <br />`T' TAP SIZE <br />LEVELING BOLT <br />TYPICAL UNIT <br />SUPPORT LEG <br />9/16 HOLE <br />2 PLACES <br />NOT TO SCALE <br />SCALE 4 <br />8NOT TO SCALE <br />SCALE <br />HANGER RODS <br />BAND (2) 1"x18 GA <br />OVER 50 INCH DIA. <br />BAND (2)1"x16 GA <br />HANGER <br />STRAP <br />RATED <br />FASTENER <br />LOAD <br />24 INCH DIA. MAX. <br />1. <br />NOTES: <br />2. <br />NOT PERMITTED) <br />(WIRE HANGERS <br />50 INCH DIA. MAX. <br />FOR UPPER ATTACHMENT TO BUILDING SEE SMACNA HVAC DUCT CONSTRUCTION STANDARDS <br />FIG. 4-1 AND FIG. 4-2, WITH SPECIFIC BUILDING STRUCTURAL ENGINEER APPROVAL. <br />3. <br /> ALSO REFER TO NATIONAL UNIFORM SEISMIC INSTALLATION GUIDELINES <br />(NUSIG) 1991 AS APPROVED BY OFFICE OF THE CALIFORNIA STATE ARCHITECT 9/25/92. <br />FOR BRACING AND OTHER SEISMIC REQUIREMENTS SEE GUIDELINES FOR SEISMIC RESTRAINTS OF <br /> MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS PUBLISHED BY SMACNA AND PPIC. <br />FOR HANGER SIZE AND SPACING, SEE SMACNA HVAC DUCT CONSTRUCTION STANDARDS <br />TABLE 4.2 <br />DAMPERS MUST BE LABELED AND LISTED BY <br />CALIFORNIA STATE FIRE MARSHALL AND/OR <br />UNDERWRITERS LABRATORIES AS A FIRE <br />DAMPER. MUST ALSO BE LEAKAGE RATED AND <br />LABLED UNDER UNDERWRITERS LABRATORIES <br />STD. 555S. METAL TO METAL NON-DEGRADABLE <br />SEALS ALLOWING NO MORE THAN 15 CFN/SQ. FT. <br />AT 1"w.g. TO 850%%F FOR A FULL 30 MINUTES <br />HEATING. CAN BE MOTOR OPERATED. TORQUE <br />REQUIRED TO MAINTAIN LEAKAGE RATE NOT TO <br />EXCEED 0 LBS. TORQUE. DAMPERS SHALL BE <br />INSTALLED PER MANUFACTURERS INSTALLATION <br />INSTRUCTIONS AND/OR STATE FIRE MARSHALL <br />LISTING NO. 3225. POTTORF COMPANY INC. <br />(LISTING NO. 3225-368-8) OR APPROVED EQUAL. <br />1 1/2 HR. & 3 HR. RATED FIRE DAMPER FOR <br />1,2,3 & 4 HOUR RATED PARTITIONS. <br />COUNTER FLASHING <br />(BY A/C CONTRACTOR) <br />FLASHING (BY A/C <br />CONTRACTOR) <br />2 x 6 CURB (BY GENERAL <br />CONTRACTOR) <br />CANT (BY GENERAL <br />CONTRACTOR) <br />ROOFING (BY GENERAL <br />CONTRACTOR) <br />SEE ARCH/ STRUCTURAL <br />PLAN FOR EXACT ROOF <br />DETAIL <br />SCALE 12NOT TO SCALE <br />SCALE <br />13NOT TO SCALE <br />SCALE 14NOT TO SCALE <br />SCALE SCALE 15NOT TO SCALE <br />SCALE <br />1. MAXIMUM LENGTH OF INSUL. FLEX <br />DUCT EQUALS 5 FEET. FLEX NOT <br />PERMITTED IN INACCESSIBLE <br />CEILINGS <br />2.INSULATED DUCT, COLLAR AND <br />DIFFUSER BY HVAC CONTRACTOR <br />3. SCOOP <br />4. SPIN IN FITTING WITH MANUAL <br />VOLUME DAMPER <br />RETURN TUBE <br />SAMPLING TUBE <br />AIR DUCT <br />SMOKE DETECTOR DETAIL <br />DUCT <br />SUPPLY <br />MAIN <br />KEYED NOTES: <br />1. MAXIMUM LENGTH OF INSUL. FLEX DUCT <br /> EQUALS 5 FEET. FLEX NOT PERMITTED <br /> IN INACCESSABLE CEILINGS <br />2. INSULATED DUCT, COLLAR AND DIFFUSER <br /> BY HVAC CONTRACTOR <br />3. SCOOP <br />4. SPIN IN FITTING WITH MANUAL VOLUME <br /> DAMPER <br />5. INTERNAL BUTTERFLY DAMPER AG-85 <br /> (PROVIDE KEY FOR ADJUSTMENT) <br />6. SECURE TO CEILING PER <br /> MANUFACTURER'S RECOMMENDATIONS <br /> AND PER CEILING FINISH. PROVIDE GRID <br /> CLIPS PER MFG'R REQUIREMENTS. <br /> PROVIDE FRAMING FOR DRYWALL <br /> INSTALLATION. <br />7. HANGER, SECURE TO STRUCTURE AND <br /> DUCTWORK <br />8. CLAMP <br />MAX. OF 5 FEET OF FLEX DUCT CAN BE INSTALLED <br />Scale <br />Date <br />Drawn By <br />Checked By <br />Project Number <br />REVISIONS <br />JOB SITE: <br />PLAN: <br />PHONE: <br />PLAN CHECK / JOB NO. <br />50 S DE LACEY AVE. STE. 210 <br />Pasadena, CA 91105 <br />THESE PLANS ARE FOR REVIEW ONLY AND NOT FOR CONSTRUCTION UNLESS THEY <br />INCLUDE THE STAMP AND SIGNATURE OF ARCHITECT/ENGINEER AND THE <br />APPROVAL OF THE APPROPRIATE GOVERNMENT AGENCY <br />C-38176 <br />MARC A. <br />ABDELSAYED <br />RENEWAL <br />DATE <br />LICENSED A R CHITECT <br />STATE OF C ALIFORNIA <br />07/31/2025 <br />369 <br />ARCHITECTS <br />As Noted <br />CA <br />N <br />A <br />M <br /> <br />D <br />E <br />N <br />T <br />A <br />L <br /> <br />- <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />MARS <br />NASRIN.P. <br />07/29/2024 <br />MISC._24065 <br />No.Description Date <br />1414 W. EDINGER AVE, <br />SANTA ANA, CA. 92704 <br />.PERMIT 09/04/2024 <br />09 <br />/ <br />0 <br />4 <br />/ <br />2 <br />0 <br />2 <br />4 <br />_ <br />G <br />C <br /> <br />C <br />o <br />m <br />m <br />e <br />n <br />t <br />1 P.C.COMMENTS 02/01/2025 <br />M-3.0 <br />MECHANICAL DETAILS