ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER <br />REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE <br />WORK. <br />PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY <br />EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE <br />CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN <br />CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE <br />SUBCONTRACTORS SOLE EXPENSE. <br />SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA <br />FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE <br />WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. <br />ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT <br />PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. <br />ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND <br />EQUIPMENT TO MATCH EXISTING FINISHES. <br />ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES <br />WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL <br />SHORT CIRCUITS, OR OTHER DAMAGE. <br />APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM THE DRAWINGS. <br />NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING <br />PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. <br />GENERAL NOTES <br />GENERAL NOTES <br />1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE <br />AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. <br />2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE <br />MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO <br />PREVENT DAMAGE. <br />3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER <br />ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, <br />COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: <br />CONDUCTOR 277/480V 120/208V <br />PHASE A BROWN BLACK <br />PHASE B ORANGE RED <br />PHASE C YELLOW BLUE <br />NEUTRAL GRAY WHITE <br />4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: <br />CONDUCTOR STD COLOR ALT COLOR <br />DC+RED RED-STRIPED <br />DC-BLACK BLACK-STRIPED <br />5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE <br />PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE <br />IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. <br />6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. <br />WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING <br />APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND <br />THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. <br />7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. <br />8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO <br />BOXES AS REQUIRED BY NRTL LISTING. <br />9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION <br />MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. <br />10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES <br />SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. <br />11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY <br />INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: <br />·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE <br />CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE <br />·ALLOWANCE FOR MOVEMENT DUE TO THERMAL <br />EXPANSION/CONTRACTION <br />·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION <br />COMPOUND <br />·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO <br />REQUIRED SETTINGS <br />12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS <br />TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER <br />TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. <br />13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT <br />FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO <br />CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT <br />THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. <br />14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE <br />FINISHED GRADE. <br />15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE <br />SHALL BE RIGID GALVANIZED STEEL. <br />16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION <br />OF USE. <br />ELECTRICAL NOTES <br />1.LOAD SIDE INTERCONNECTIONS SHALL COMPLY WITH NEC ART 705.12(B). <br />2.WHERE THE INTERCONNECTION POINT OCCURS ON FEEDERS, THE FEEDER <br />AMPACITY SHALL NOT BE LESS THAN THE SUM OF ALL THE SOURCES <br />CONNECTED TO THE FEEDER UNLESS THE FEEDER IS PROTECTED ON THE <br />LOAD SIDE OF THE INTERCONNECTION POINT WITH OVERCURRENT <br />PROTECTION NO GREATER THAN THE AMPACITY OF THE FEEDER. <br />3.TAP CONNECTIONS SHALL COMPLY WITH ART 240.21(B). <br />4.WHERE THE SUM OF ALL THE OVERCURRENT DEVICE RATINGS ON THE <br />PANEL LOAD SIDE OF A MAIN OVERCURRENT PROTECTION DEVICE ARE LESS <br />THAN THE RATING OF THE PANEL, PERMANENT WARNING LABELS WITH THE <br />FOLLOWING WORDING MUST BE APPLIED: <br />WARNING: <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. <br />5.WHERE THE SUM OF THE UTILITY OVERCURRENT DEVICE AND 125% OF <br />INVERTER OUTPUT CIRCUIT CURRENT DOES NOT EXCEED 120% OF THE <br />RATING OF THE BUSBAR, THE INTERCONNECTION POINT MUST BE ON THE <br />OPPOSITE END OF THE BUSBAR FROM THE INCOMING UTILITY SOURCE AND <br />A PERMANENT WARNING LABEL MUST BE APPLIED TO THE <br />INTERCONNECTION POINT. <br />6.LOAD SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE <br />EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE <br />THE NRTL LISTING OF THE EQUIPMENT. WHERE EXISTING NRTL LISTING <br />CANNOT BE MAINTAINED, EQUIPMENT MUST BE RELISTED BY AN APPROVED <br />NRTL SUITABLE FOR THE EQUIPMENT. <br />UTILITY-INTERACTIVE INVERTER <br />LOAD-SIDE INTERCONNECTION NOTES <br />1.CAT5E/6 SHIELDED CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS <br />OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL <br />DISTANCE OF 328 FEET (100M) PER CHAIN. <br />2.RS485 CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF <br />INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL DISTANCE <br />OF 3280 FEET (1000M) PER CHAIN. <br />3.SWITCHES, METERS, POWERPACK CONTROLLERS, CT'S, AND PT'S, AND <br />CONDUCTORS MARKED "PRE-INSTALLED" IN THE LINE DIAGRAM WILL ARRIVE <br />TO SITE PRE-INSTALLED WITHIN THE SWITCHBOARD, AND WILL NOT REQUIRE <br />ANY FIELD INSTALLATION OR MODIFICATION OF ANY KIND. <br />4.FIBER OPTIC CABLE RUNS SHALL UTILIZE OUTDOOR DUCT OR DIRECT BURIAL <br />RATED SINGLE MODE (OS2) CABLES COMPATIBLE WITH COMMUNICATION <br />WAVELENGTHS BETWEEN 1310 - 1550 NM. <br />COMMUNICATION NOTES <br />GENERAL NOTES <br />1.REFER TO THE SPECIFIC PRODUCT MANUFACTURER'S INSTALLATION AND <br />OPERATION MANUAL FOR MORE INFORMATION. <br />2.BATTERY ENERGY STORAGE SYSTEM (BESS) SHALL BE SERVICED ONLY BY <br />MANUFACTURER-CERTIFIED TECHNICIANS. <br />3.SECONDARY CONTAINMENT IS NOT REQUIRED FOR THE BATTERY BESS. <br />4.BATTERY PACK DC CONNECTIONS TO BESS INVERTER SHALL ONLY BE MADE <br />WITH MANUFACTURER-PROVIDED CONDUCTOR HARNESSES. <br />5.BESS DISCONNECTING MEANS SHALL BE LABELED PER ART 706.7(D). BESS <br />AND INTERCONNECTION SHALL BE LABELED PER ART 706.11. <br />BESS NOTES <br />SITE LEGEND <br />(E) ACCESSIBLE PARKING <br />SPACE <br />(E) LIGHT POLE <br />FH (E) FIRE HYDRANT <br />G <br />E <br />SS <br />SD <br />T <br />TV <br />? <br />W <br />GV <br />HB <br />IV <br />WV <br />WR <br />T <br />CO <br />(E) STORM MANHOLE <br />(E) GUY WIRE - ELECTRIC <br />(E) HOSE BIB <br />(E) GAS VALVE <br />(E) IRRIGATION VALVE <br />(E) WATER VALVE <br />(E) SPRINKLER HEAD <br />(E) WATER RISER <br />(E) SPRINKLER HEAD <br />(E) CLEANOUT <br />(E) ELECTRIC MANHOLE <br />(E) GAS MANHOLE <br />(E) SANITARY SEWER <br />MANHOLE <br />(E) TELEPHONE MANHOLE <br />(E) TELEVISION MANHOLE <br />(E) UNKNOWN MANHOLE <br />(E) POTABLE WATER <br />MANHOLE <br />(E) UTILITY POLE - <br />ELECTRIC <br />(E) UTILITY POLE - <br />TELEPHONE <br />(E) GUY WIRE <br />(E) TREE <br />UE (E) UNDERGROUND <br />ELECTRIC LINE <br />ST (E) UNDERGROUND <br />STORM DRAIN LINE <br />WL (E) UNDERGROUND <br />WATER LINE <br />UG (E) UNDERGROUND <br />GAS LINE <br />OE (E) OVERHEAD <br />ELECTRIC LINE <br />UT (E) UNDERGROUND <br />TELEPHONE LINE <br />SS (E) UNDERGROUND <br />SANITARY SEWER LINE <br />(E) VENT PIPE <br />(E) ROOF ACCESS HATCH <br />(E) EXHAUST FAN <br />(E) SKYLIGHT <br />(E) HVAC UNIT <br />(E) OPERABLE SKYLIGHT <br />(E) CONDENSATION <br />CONDUIT LINEWL <br />GAS <br />ELE <br />(E) GAS CONDUIT LINE <br />(E) ELECTRICAL <br />CONDUIT LINE <br />(E) UTILITY POLE <br />GENERAL NOTES <br />1.TESLA, AT THE TIME OF INSTALLATION, SHALL CONFIGURE THE AUGMENTED <br />MEGAPACKS SUCH THAT: <br />1.1.THE INTERNAL MEGAPACK CONTROLLER ADJUSTS THE MAXIMUM <br />ALLOWABLE CURRENT OF THE INVERTERS WITH FIRMWARE SO THAT <br />THE AUGMENTED MEGAPACK'S CURRENT CAPABILITY AND THUS KVA <br />RATING ARE MAINTAINED, REGARDLESS OF THE NUMBER OF INVERTERS. <br />1.2.THE CURRENT IS LIMITED AT THE INVERTER LEVEL, THE SHORT-CIRCUIT <br />CONTRIBUTION OF THE AUGMENTED MEGAPACK REMAINS UNCHANGED. <br />BESS AUGMENTATION NOTES <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DA <br />T <br />E <br />NO <br />. <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />ORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />CA <br />L <br />P <br />I <br />N <br />E <br /> <br />I <br />I <br />13 <br />1 <br />2 <br /> <br />E <br /> <br />W <br />A <br />R <br />N <br />E <br />R <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />NOTES <br />G-002 <br />REV: 0 PERMIT <br />VQUIRINDONGOPLOT DATE: 10/27/2023 9:36 AM <br />JB-###### <br />  <br />CA <br />L <br />P <br />I <br />N <br />E <br /> <br />- <br />- <br /> <br />P <br />H <br />A <br />S <br />E <br /> <br />2 <br />ME <br />G <br />A <br />P <br />A <br />C <br />K <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />A <br />U <br />G <br />M <br />E <br />N <br />T <br />A <br />T <br />I <br />O <br />N <br />1312 E Warner Ave - <br />101117461 & 201815044/29/2024