My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1206 W 18th St - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Eighteenth St
>
1206 W Eighteenth St
>
1206 W 18th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:22:59 PM
Creation date
6/6/2025 1:22:28 PM
Metadata
Fields
Template:
Plan
Permit Number
20180998
101116661
101117404
Full Address
1206 W Eighteenth St
Document Relationships
101116661 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Eighteenth St\1206 W Eighteenth St
101117404 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Eighteenth St\1206 W Eighteenth St
20180998 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Eighteenth St\1206 W Eighteenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: B <br />AHJ: CA-CITY OF SANTA ANA <br />33.761013, -117.882958 <br />APN: 39908502 <br />NAME: ANTHONY LIMA & DONNA <br />AMADRIL <br />DRAFTED BY: VASANTH KUMAR <br />ADDRESS: 1206 W 18TH ST, SANTA <br />ANA, CA 92706 <br />PHONE: (949) 434-6066 <br />UTILITY: SCE-SOUTHERN <br />CALIFORNIA EDISON <br />SCALE: AS NOTED <br />PRN NUMBER: SMT-78832 <br />PAPER SIZE: 17"X11"SHEET: E-03DATE: 06/26/2023 <br />DRAWING INFORMATION <br />CUSTOMER INFORMATION CONTRACTOR INFORMATION <br />QC'ED BY: RAAGUL REVANTH <br />ELECTRICAL NOTES <br />ELECTRICAL CALCULATIONS <br />SOLARMAX RENEWABLE ENERGY <br />PROVIDER INC. <br />3080 12TH ST, RIVERSIDE, CA 92507 <br />TEL: (951) 300-0788 <br />LICENSE NUMBER& <br />CLASS:972048/C-46 <br />David Bingwen Hsu <br /> David Bingwen Hsu, Lic. Holder <br />DC SYSTEM SIZE- 6365W, AC SYSTEM SIZE - 5510W, CEC AC RATING - 5658W <br />ENPHASE IQ8PLUS-72-2-US <br />(240V)(SI-1) <br />MICRO INVERTER SPECIFICATIONS <br />MODEL <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />9.85 AMAX POWER CURRENT:Imp <br />10.39 ASHORT CIRCUIT CURRENT:Isc <br />34.07 VMAX POWER VOLTAGE:Vmp <br />41.59 VOPEN CIRCUIT VOLTAGE:Voc <br />335 WMODULE POWER @ STC <br />MODEL <br />MODULE SPECIFICATION <br />SUNSPARK SST-335M3B-60 (335W) <br />OCPD CALCULATION <br />ALLOWABLE BACKFEED: <br />MAIN PANEL RATING = 225 A <br />MAIN BREAKER RATING = 200 A <br />120% RULE: = ((MAIN PANEL RATING * 1.2) - MAIN BREAKER RATING) <br />= ((225 A*1.2)-200 A) <br />= 70 A <br />ALLOWABLE BACKFEED = 70 A <br />INVERTER OVERCURRENT PROTECTION: <br />INVERTER OVERCURRENT PROTECTION = (MICROINVERTER O/P CURRENT * # OF MICROINVERTER <br /> * CONTINUOUS LOAD(1.25)) <br />= (1.21 * 19 *1.25) <br />= 28.74 A <br />PV BREAKER = 30 A ≥ 28.74 A <br />ALLOWABLE BACKFEED 70 A ≥ 30 A OF PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(3)(2) REQUIREMENTS. <br />TAG 1: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 * 10 * 1.25) <br /> CORRECTED AMPACITY CALCULATION(0.96 * 1 * 30) <br />15.12 A < 28.8 A <br />TAG 2: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 * 10 * 1.25) <br /> CORRECTED AMPACITY CALCULATION(0.96 * 0.8 * 40) <br />15.12 A < 30.72 A <br />TAG 3: (AC) <br /> REQUIRED CONDUCTOR AMPACITY(1.21 * 19 * 1.25) <br /> CORRECTED AMPACITY CALCULATION(0.96 * 1 * 40) <br />28.74 A < 38.4 A <br />= 15.12 A <br />= 28.8 A <br />= 15.12 A <br />= 30.72 A <br />= 28.74 A <br />= 38.4 A <br />WIRE SIZE CALCULATIONS <br />AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS <br />REQUIRED CONDUCTOR AMPACITY: <br /> INVERTER OUTPUT CURRENT * #OF INVERTERS = MAX CURRENT PER 690.8(A)(1)(e)* 125% <br /> = MAX CURRENT PER 690.8(B)(1) <br />CORRECTED AMPACITY CALCULATIONS: <br /> DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) = AMPACITY * TEMPERATURE DERATE FACTOR * <br /> CONDUIT FILL DERATE <br /> DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(1) < DERATED CONDUCTOR AMPACITY <br />1. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS <br />SUNLIGHT RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE <br />SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE <br />NOTED. <br />5. BREAKER/FUSE SIZES PER CEC 240. <br />6. AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC <br />250.122. <br />7. THE AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED <br />ON CEC 690.31(A). <br />8. THE AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED <br /> ON CEC 310.15(B)(1). <br />9. MAX SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER CEC TABLE 310.16. <br />1206 W 18th St <br />09/18/23
The URL can be used to link to this page
Your browser does not support the video tag.