My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
118 W Stevens Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Stevens Ave
>
118 W Stevens Ave
>
118 W Stevens Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:23:04 PM
Creation date
6/6/2025 1:22:29 PM
Metadata
Fields
Template:
Plan
Permit Number
20182343
20183019
101117734
101118569
Full Address
118 W Stevens Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wyssling Consulting <br />76 N. Meadowbrook Drive <br />Alpine, UT 84004 <br />(201) 874-3483 <br />swyssling@wysslingconsulting.com <br />V =95 Basic Wind Speed Mangosing Residence <br />Exposure C ASCE 7-16, Section 26.7 118 W Stevens Avenue <br />Kz =0.94 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA <br />Kzt =1 Topographic Factor, ASCE 7-16, Section 26.8.2 <br />Kd =0.85 Directionality Factor, ASCE 7-16, Section 26.6 <br />Ke =0.999 Ground Elevation Factor, ASCE 7-16, Section 26.9 <br />qh =18.4 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) <br />Roof Angle =18.43 deg <br />Roof Type Gable <br />sanchor =48 in Horizontal spacing of roof anchors <br />Atrib =12.51 sf Panel Area tributary to each roof anchor <br />GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 <br />Roof Zone Zone 1 2e 2n 2r 3e 3r <br />-2.00 -2.00 -2.98 -2.98 -2.98 -3.55 <br />ga =0.79 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 <br />gE =1.00 Edge Array Factor, ASCE 29.4.4 edges < 0.5*building height, and panel spacing < 4ft. <br />pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 <br />Roof Zone 1 2e 2n 2r 3e 3r <br />-29 psf -29 psf -43 psf -43 psf -43 psf -52 psf Min Pressure = -16 psf <br />Use 29 psf Use 29 psf Use 43 psf Use 43 psf Use 43 psf Use 52 psf ULTIMATE <br />x 0.6 =17 psf 17 psf 26 psf 26 psf 26 psf 31 psf ALLOWABLE <br />Connection to Existing Roof Framing <br />F.S. =1 Additional Factor of Safety applied to withdrawl force, if desired <br />Atrib =12.5 ft2 <br />DLpanel =3 psf <br />Roof Zone 1 2e 2n 2r 3e 3r <br />Wuplift =29 psf 29 psf 43 psf 43 psf 43 psf 52 psf <br />Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor <br />Roof Zone 1 2e 2n 2r 3e 3r <br />-199.3 lbs -199.3 lbs -306.2 lbs -306.2 lbs -306.2 lbs -368.5 lbs <br />Connection Capacity <br />db =1/4 in Lag Screw diameter <br />Dpen =2 1/2 in Lag Screw penetration into existing framing member <br />No. of Screws 2 Screws per Connection <br />Species of wood framing <br />CD =1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 <br />Ct =0.7 Temperature Factor, NDS Table 10.3.4 <br />W =173 lb/in Withdrawl Capacity, NDS Equation 11.2-1 <br />W' = CD x Ct x W =194 lb/in Adjusted withdrawl value <br />Pallow = Dpen x W' =970 lbs (Using (2) screws per connection) <br />Roof Zone 1 2e 2n 2r 3e 3r <br />DEMAND =199 lbs 199 lbs 306 lbs 306 lbs 306 lbs 369 lbs <br />CAPACITY =970 lbs 970 lbs 970 lbs 970 lbs 970 lbs 970 lbs <br />up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok up to72in ok <br />This analysis calculates the <br />capacity of the lag screws <br />only. For capacity of the <br />complete mounting system, <br />please see manufacturer's <br />recommendations. <br />Spruce-Pine-Fir <br />Wind Uplift <br />Rooftop Solar Panels Parallel to Roof Surface <br />ASCE 7-16, Section 29.4.4 <br />Signed 1/04/2024 <br />118 W Stevens Ave - <br />201817302/22/2024
The URL can be used to link to this page
Your browser does not support the video tag.