My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
701 W Park Ln - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Ln
>
701 W Park Ln
>
701 W Park Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:23:13 PM
Creation date
6/6/2025 1:22:44 PM
Metadata
Fields
Template:
Plan
Permit Number
20178515
101113573
101114350
Full Address
701 W Park Ln
Document Relationships
101113573 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\701 W Park Ln
101114350 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\701 W Park Ln
20178515 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\701 W Park Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
System Components <br />PV Mods MicroInverters <br />Make Q.Antum Duo Z Make Enphase <br />Model Q.PEAK DUO BLK <br />ML-G10+ 400 Model IQ8PLUS-72-2-US <br />Imp (A)10.77 Max DC Volt Rating (V)60 <br />Vmp (V)37.13 Min DC Volt Rating (V)25 <br />Voc (V)45.3 AC Nomial Voltage (V)240 <br />Isc (A)11.14 Peak Efficiency (%)97.6 <br />Pmax (W)400 Max Per Branch 13 <br />VOC Temp Coeff (%) -0.27 <br />System Calculations <br />Module Pmax Module Count Inverter Efficiency DC System Size <br />400 14 N/A 5.600 <br />Module PTC Rating <br />(CEC)Module Count Inverter Efficiency AC System Size <br />371.500 14 97% 5.045 <br />String Calculations <br />String # of Modules Max Cont. Current (V) Amps per Modules Max Designed Amps <br />1 1.21 1.25 9.075 <br />2 1.21 1.25 <br />3 0 0 0 0 <br />4 0 0 0 0 <br />5 0 0 0 0 <br />6 0 0 0 0 <br />Total 14 21.175 <br />Main Panel Info <br />Service Type Overhead <br />Main Panel Disconnect 200 <br />Main Panel Bus 200 <br />Service Wire Size # 2/0 AWG <br />Grounding Electrode Size # 4 AWG <br />Conduit Size 1-1/2" <br />Conductor Sizing <br />Tag Number Description AWG Type Material # of <br />Conductors <br /># of Current <br />Carrying <br />Conductors <br />Conduit Size Ampacity Fill Derate Temp Derate Derated <br />Ampacity Max Current <br />1 Module to Junction Box 12 Q Cable CU 3 2 N/A 30 1 0.91 27.3 12.1 <br />1.1 Module to Junction Box 12 Q Cable CU 3 2 N/A 30 1 0.91 27.3 9.075 <br />2 Junction Box to Combiner 12 THHN CU 3 2 3/4"30 1 0.91 27.3 12.1 <br />2.1 Junction Box to Combiner 12 THHN CU 3 2 3/4"30 1 0.91 27.3 9.075 <br />3 Combiner to Main Panel 10 THHN CU 4 3 3/4"40 1 0.91 36.4 21.175 <br />3.1 Combiner to Subpanel 10 THHN CU 4 3 3/4"40 1 0.91 36.4 21.175 <br />Interconnection Calculations <br />Max Output current @ 125% Backfeed Breaker Size (A) Panel Bus Bar Rating (A) Panel Breaker Size (A)Bus X 120%Amps Availiable 120% Rule <br />21.175 30 200 200 240 40 OKAY <br />701 W Park Ln <br />02/13/23
The URL can be used to link to this page
Your browser does not support the video tag.