My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2529 N Valencia St - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Valencia St
>
2529 N Valencia St
>
2529 N Valencia St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:23:14 PM
Creation date
6/6/2025 1:22:47 PM
Metadata
Fields
Template:
Plan
Permit Number
20179483
20179889
101114904
101116798
Full Address
2529 N Valencia St
Document Relationships
101114904 - Permit
(Permit - Plan)
Path:
\Building\Permits\V\Valencia St\2529 N Valencia St
101116798 - Permit
(Permit - Plan)
Path:
\Building\Permits\V\Valencia St\2529 N Valencia St
20179483 - Permit
(Permit - Plan)
Path:
\Building\Permits\V\Valencia St\2529 N Valencia St
20179889 - Permit
(Permit - Plan)
Path:
\Building\Permits\V\Valencia St\2529 N Valencia St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project Name: <br />Zetulio Jimenez <br />Property address: <br />2529 Valencia St N, <br />Santa Ana, CA 92706 <br />APN:39642203 <br />DATE:03/29/2023 <br />CONTRACTOR <br />Vibe Solar <br />Lic #: 1036012 <br />Lic class: C-10 <br />Address: 1206 Commerce Center Dr <br />#103 Lancaster, CA 93534 <br />Phone number: (661) 485-5000 <br />E-mail: xiomara@vibesolar.com <br />SIGNAGEPV.2 <br />1 <br />2 <br />(STICKER TO BE LOCATED ON <br />CONDUIT WITH DC CURRENT <br />EVERY 4' HORIZONTALLY OR <br />10' VERTICALLY AND 1' FROM <br />EACH SIDE OF A BEND) <br />3 <br />4 <br />10 <br />(TO BE LOCATED ON <br />SUB-PANEL ONLY <br />WHEN SUB-PANEL IS <br />DEDICATED FOR PV ONLY) <br />5 <br />6 <br />7 <br />8 <br />(STICKER LOCATED <br />INSIDE PANEL <br />NEXT TO SOLAR BREAKER) <br />9 <br />(STICKER LOCATED <br />INSIDE PANEL <br />BELOW PV BREAKER) <br />PV ARRAY <br />J BOX <br />PV SUB-PANEL <br />*if applicable <br />SUB-PANEL <br />*if applicable <br />AC <br />DISCONNECT <br />*if applicable <br />METER <br />MAIN SERVICE <br />PANEL <br />2 <br />1 <br />5 <br />6 <br />8 <br />7 <br />9 <br />6 <br />8 <br />7 <br />9 <br />6 <br />6 <br />8 <br />7 <br />9 <br />12 <br />(STICKER LOCATED <br />ON THE PV SUB PANEL) <br />10 <br />11 <br />(STICKER LOCATED <br />ON THE MAIN SERVICE PANEL) <br />11 <br />CAUTION <br />AUTHORIZED SOLAR <br />PERSONNAL ONLY! <br />CAUTION <br />SOLAR DC CURRENT PRESENT <br />DURING DAYLIGHT HOURS <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br /> UNGROUNDED AND ENERGIZED. <br />WARNING! <br />ELECTRIC SHOCK HAZARD. <br />DO NOT TOUCH THE TERMINALS. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION. <br />PV LOAD CENTER SIZED FOR PV <br />BREAKERS ONLY OR RENDERED UNABLE <br />TO ACCEPT ANY ADDITIONAL LOADS. <br />PV SUB-PANEL ONLY <br />AC DISCONNECT <br />AC PHOTOVOLTAIC POWER SOURCE <br />RATED AC OUTPUT CURRENT: MAX <br />NOMINAL AC OPERATING VOLTAGE: Vac <br />THIS PANEL FED BY <br />MULTIPLE SOURCES <br />(UTILITY & SOLAR) <br />SOLAR <br />WARNING! <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUT DOWN <br />Permanent directory or plaque <br />providing location of service <br />disconnecting means and <br />photovoltaic system disconnecting <br />means, if not located at the same <br />location. (Plaques shall be metal or <br />plastic, with engraved or machine <br />printed letters, or electro-photo plating, <br />in a contrasting color to the plaque. <br />Plaques shall be permanently attached <br />to the equipmenq or in the required <br />location using an approved method that <br />is suitable to withstand the environment <br />to which it is exposed. Plaques and <br />signage shall meet legibility, <br />defacemet, exposure and adhesion <br />requirements of Underwriters <br />Laboratories marking and labeling <br />system 969(UL969). <br />MARKINGS, LABELS AND WIRING SIGNS <br />A. Purpose: Provide emergency responders with appropriate warning and guidance with <br />respect to isolating solar electric system. <br />This can facilitate identifying energized electrical lines that connect solar panels to the <br />inverter, as these should not be cut when venting for smoke removal <br />B. Main Service Disconnect. <br />1. Residential buildings - The marking main be placed within the main service <br />disconnect. The marking shall be placed <br /> outside cover if the main service disconnect is operable with the service panel closed. <br />2. Commercial buildings - Tha marking shall be placed adjacent to the main service <br />disconnect clearly visible from the location where the level is operated <br />3. Markings: Verbiage, Format and Type of Material. <br />a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All <br />letters shall be capitalized. Arial or similar font, non bold. <br />c. Material: Reflective, weather resistant material suitable for the environment (use UL - <br />969 as standard for weather rating). Durable adhesive materials meet this requirement. <br />C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC <br />combiners and junction boxes: <br />1. Markings: Verbiage, Format and Type of Material. <br />a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC <br />conduits, raceways, enclosures, and cable assemblies, <br />at turns, above and for below penetrations, all DC combiners and junction boxes <br />b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall <br />adhere to "V. V-3b, c" of this requirement. <br />c. Inverters are not required to have caution markings <br />1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable <br />assemblies,and junction boxes,combiner boxes and disconnects. <br />2.The materials used for marking shall be reflective,weather resistant material suitable <br />for the environment. <br />Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background <br />with white lettering. <br />3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. <br />4.Marking shall be placed adjacent to the main service disconnect in a location clearly <br />visible from the location where the disconnect is operated <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />N <br /> 0° <br />S <br /> 180 ° <br />E <br /> 90 ° <br />W <br /> 270 ° <br />13 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />28.73 <br />240 <br />(RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM) <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />SERVICE POINT & <br />UTILITY METERING <br />AC DISCONNECT <br />ENPHASE COMBINER <br />SOLAR PV ARRAY <br />You Are <br />Here <br />2529 N Valencia St <br />05/30/23
The URL can be used to link to this page
Your browser does not support the video tag.