My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2202 N Santiago St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Santiago St
>
2202 N Santiago St
>
2202 N Santiago St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:23:12 PM
Creation date
6/6/2025 1:22:49 PM
Metadata
Fields
Template:
Plan
Permit Number
20178434
101113475
Full Address
2202 N Santiago St
Document Relationships
101113475 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Santiago St\2202 N Santiago St
20178434 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Santiago St\2202 N Santiago St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NO <br />NO <br />3THWN-2 <br />EGC: THWN-2 1 <br />NO <br />#10 <br />#10 <br />EMT 3/4"C <br />C <br /> (N) LOAD CENTER <br /> MIN., 120/240 V, <br />M.L.O, NEMA-3R <br />LOCATION: <br />GND <br />YES <br />20A, 2P <br />20A, 2P <br />EXTERIOR WALL <br />100A <br />15A, 2P <br />ETHERNET <br />CONNECTION TO <br />DSL/CABLE MODEM <br />CAT5e <br />PVS6 <br />(3) #14 THWN <br />(1) #14 THWN EGC <br />NONO <br />EGC: Bare CU #6 <br />BRANCH CIRCUIT <br />FROM PV ARRAY TO <br />JUNCTION BOX <br />#12 2 <br />A -- <br />1 <br />B <br />JUNCTION BOX, <br />NEMA-3R <br />THWN-2 <br />EGC: THWN-2 1 <br />4 <br />B <br />3 <br />#10 <br />#10 <br />EMT 3/4" <br />#10 <br />#10 <br />CONDUCTOR / CONDUIT SCHEDULE <br />DESCRIPTION & <br />CONDUCTOR TYPE <br />CONDUCTOR SIZE <br />(AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF <br />CONDUCTORS <br />1 <br />ROOFTOP <br />ARRAY WIRING A <br />DC <br />AC Branch Circuit #1AC <br />DC <br />AC Branch Circuit #2 <br />4 AC MODULES <br />9 AC MODULES <br />TAG <br />H <br />(E) UTILITY <br />BIDIRECTIONAL <br />METER #: <br />222013-462392 <br />EXISTING <br />GROUND <br />NO <br />MLO <br /> GROUNDED (INCLUDE GEC) UNGROUNDEDü <br />INSTALLATION NOTES <br />1 <br />CHECK BOX FOR WHETHER SYSTEM IS GROUNDED <br />OR UNGROUNDED: <br />FOR UNGROUNDED SYSTEMS: <br />· DC OCPD DISCONNECT BOTH CONDUCTORS OF <br />EACH SOURCE CIRCUIT. <br />· UNGROUNDED CONDUCTORS MUST BE <br />IDENTIFIED PER 210.5(C). WHITE FINISHED <br />CONDUCTORS ARE NOT PERMITTED. <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />DC / DC CONVERTERS NO <br />SOURCE CIRCUIT JUNCTION BOX <br />SUNVAULT ESS <br />SUNVAULT BATTERY INVERTER <br />SOLAR LOAD CENTER <br />PV PRODUCTION METER <br />SEPARATE AC DISCONNECT <br />HEAT DETECTOR <br />YES <br />NO <br />11 <br />13 <br />BACK UP LOAD CENTER <br />NON-BACK UP LOAD CENTER <br />EV SUPPLY EQUIPMENT <br />NO <br />TAG DESCRIPTION <br />12 <br />REMOTE POWER OFF SWITCH <br />14 <br />HUB+ <br />INCOMING SOURCE FEED <br /> , 120/240 V, 1 PH, 3 W <br /> *MSP MAX PV BREAKER (A): <br />x 120% - <br />= <br />LOCATION: <br />MANUF: <br />GND <br />MCB <br />CENTER FED <br />NOTE: <br />"PER NEC 705.12(B)(2)(3)(d), A CONNECTION AT <br />EITHER END, BUT NOT BOTH ENDS, OF A <br />CENTER-FED PANELBOARD IN DWELLINGS <br />SHALL BE PERMITTED WHERE THE SUM OF 125 <br />PERCENT OF THE POWER SOURCE(S) OUTPUT <br />CIRCUIT CURRENT AND THE RATING OF THE <br />OVERCURRENT DEVICE PROTECTING THE <br />BUSBAR DOES NOT EXCEED 120 PERCENT OF <br />THE CURRENT RATING OF THE BUSBAR. <br />(E) LOADS <br />(E) LOADS <br />(E) LOADS <br />GND <br />200A, 2P <br />40A <br />200A <br />30A, 2P <br />EXTERIOR WALL <br />SQUARE D <br />200A 200A <br />(E) MAIN SERVICE PANEL <br />1 PV MODULE <br />MICROINVERTER (FIELD-INSTALLED) <br />MISOLAR / BRANCH 1. PROPER LISTING EXPECTED FOR CONDITIONS <br />OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. <br />2. ALL CONDUIT BEND RADII TO CONFORM TO <br />THE NEC MINIMUM BEND RADII <br />REQUIREMENTS. <br />3. MINIMUM CLEARANCE SHALL BE MAINTAINED <br />PER NEC FOR ALL NEW EQUIPMENT TO BE <br />INSTALLED. <br />4. EXISTING GROUNDING ELECTRODE SYSTEM <br />MUST MEET NEC AND LOCAL UTILITY <br />REQUIREMENTS. <br />5. COPPER CONDUCTORS SHALL BE USED <br />UNLESS SPECIFIED. <br />6. TYPE NM (ROMEX) CONDUCTORS ARE <br />ALLOWED FOR INTERNAL AND ATTIC RUNS <br />AND SHALL BE INSTALLED MEETING NEC <br />REQUIREMENTS. <br />7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, <br />IT WILL BE PERMITTED AND INSTALLED BY <br />3RD PARTY. <br />8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP <br />EXCEEDS 2%. <br />9. RUN CONDUCTORS IN EXISTING CONDUIT <br />WHEN AVAILABLE PROVIDED IT HAS NO <br />OTHER CONDUCTORS RUNNING THROUGH IT. <br />10. EQUIVALENT SPECIFICATION ON CABLES AND <br />ELECTRICAL EQUIPMENT SPECIFIED ARE <br />ACCEPTABLE. <br />ELECTRICAL NOTES <br />SUNPOWER PROVIDED MICROINVERTER <br />EXTENSION CABLE, LISTED AS AN ASSEMBLY <br />MAKE/MODEL: ENPHASE IQ7HS-66-M-US [240] | QTY: 13 <br />MAKE/MODEL: WAAREE ENERGIES LIMITED WSMDI-400 | QTY: 13 <br />NO <br />NO <br />PROJECT <br />INSTALLER <br />1 <br />4 <br /> <br />1 <br /> <br />4 <br /> <br /> <br />H <br />A <br /> <br />R <br /> <br />B <br /> <br />O <br /> <br />U <br /> <br />R <br /> <br /> W <br /> <br />A <br /> <br />Y <br /> <br /> S <br /> <br />O <br /> <br />U <br /> <br />T <br /> <br />H <br />R I <br /> <br />C <br /> <br />H <br /> <br />M <br /> <br />O <br /> <br />N <br /> <br />D <br /> <br />, <br /> <br /> C <br /> <br />A <br /> <br /> <br /> <br />9 <br />4 <br /> <br />8 <br /> <br />0 <br /> <br />4 <br />( <br />5 <br /> <br />1 <br /> <br />0 <br /> <br />) <br /> <br /> 5 <br /> <br />4 <br /> <br />0 <br /> <br />- <br /> <br />0 <br /> <br />5 <br /> <br />5 <br /> <br />0 <br />C <br />O <br /> <br />R <br /> <br />P <br /> <br />O <br /> <br />R <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />, <br /> <br /> <br /> <br />S <br />Y <br /> <br />S <br /> <br />T <br /> <br />E <br /> <br />M <br /> <br />S <br />R E V I S I O N S <br />SO <br />L <br />A <br />R <br /> <br />I <br />N <br />D <br />I <br />V <br />I <br />D <br />U <br />A <br />L <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />REV DESCRIPTION DATE DB <br />DRAWN BY: <br />DATE DRAWN <br />SCALE <br />KA <br />T <br />H <br />R <br />Y <br />N <br /> <br />W <br />I <br />L <br />S <br />O <br />N <br />22 <br />0 <br />2 <br /> <br />S <br />A <br />N <br />T <br />I <br />A <br />G <br />O <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />RP-373538 <br />5. <br />2 <br />0 <br /> <br />k <br />W <br />SPRI - ANAHEIM <br />12-12-2022 <br />C. Holgado <br />CHARLENE HOLGADO <br />SHEET <br />NTS <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br />- <br />L <br />I <br />N <br />E <br /> <br />D <br />I <br />A <br />G <br />R <br />A <br />M <br />& <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />PVE-1 <br />2202 N Santiago St <br />01/25/23
The URL can be used to link to this page
Your browser does not support the video tag.