NO <br />3THWN-2 <br />EGC: THWN-2 1 <br />NO <br />#10 <br />#10 <br />EMT 3/4"C <br />C <br /> (N) LOAD CENTER <br /> MIN., 120/240 V, <br />M.L.O, NEMA-3R <br />LOCATION: <br />GND <br />YES <br />20A, 2P <br />20A, 2P <br />SOUTH <br />100A <br />15A, 2P <br />ETHERNET <br />CONNECTION TO <br />DSL/CABLE MODEM <br />CAT5e <br />PVS6 <br />(3) #14 THWN <br />(1) #14 THWN EGC <br />NO <br />NO <br />EGC: Bare CU #6 <br />BRANCH CIRCUIT <br />FROM PV ARRAY TO <br />JUNCTION BOX <br />#12 2 <br />A -- <br />1 <br />B <br />JUNCTION BOX, <br />NEMA-3R <br />THWN-2 <br />EGC: THWN-2 1 <br />4 <br />B <br />3 <br />#10 <br />#10 <br />EMT 3/4" <br />#10 <br />#10 <br />CONDUCTOR / CONDUIT SCHEDULE <br />DESCRIPTION & <br />CONDUCTOR TYPE <br />CONDUCTOR SIZE <br />(AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF <br />CONDUCTORS <br />1 <br />ROOFTOP <br />ARRAY WIRING A <br />DC <br />AC Branch Circuit #1AC <br />DC <br />AC Branch Circuit #2 <br />6 AC MODULES <br />6 AC MODULES <br />TAG <br />H <br />(E) UTILITY <br />BIDIRECTIONAL <br />METER #: <br />222012782899 <br />EXISTING <br />GROUND <br />NO <br />MLO <br />NO <br /> GROUNDED (INCLUDE GEC) UNGROUNDEDü <br />INSTALLATION NOTES <br />1 <br />CHECK BOX FOR WHETHER SYSTEM IS GROUNDED <br />OR UNGROUNDED: <br />FOR UNGROUNDED SYSTEMS: <br />· DC OCPD DISCONNECT BOTH CONDUCTORS OF <br />EACH SOURCE CIRCUIT. <br />· UNGROUNDED CONDUCTORS MUST BE <br />IDENTIFIED PER 210.5(C). WHITE FINISHED <br />CONDUCTORS ARE NOT PERMITTED. <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />DC / DC CONVERTERS NO <br />SOURCE CIRCUIT JUNCTION BOX <br />SUNVAULT ESS <br />SUNVAULT BATTERY INVERTER <br />SOLAR LOAD CENTER <br />PV PRODUCTION METER <br />SEPARATE AC DISCONNECT <br />HEAT DETECTOR <br />YES <br />NO <br />11 <br />13 <br />BACK UP LOAD CENTER <br />NON-BACK UP LOAD CENTER <br />EV SUPPLY EQUIPMENT <br />NO <br />NO <br />NO <br />TAG DESCRIPTION <br />12 <br />REMOTE POWER OFF SWITCH <br />14 <br />HUB+ <br />INCOMING SOURCE FEED <br /> , 120/240 V, 1 PH, 3 W <br /> *MSP MAX PV BREAKER (A): <br />x 120% - <br />= <br />LOCATION: <br />MANUF: <br />GND <br />TOP FED <br />MCB <br />PV BREAKER: TO BE <br />INSTALLED ON THE OPPOSITE SIDE <br />OF THE MAIN OCPD OF THE BUSBAR <br />(E) LOADS <br />(E) LOADS <br />(E) LOADS <br />GND <br />200A, 2P <br />70A <br />225A <br />30A, 2P <br />SOUTH <br />------- <br />225A 200A <br />(N) MAIN SERVICE PANEL <br />SUNPOWER AC MODULES <br />INTERGRATED WITH MICROINVERTER <br />1 <br />ACMSOLAR AC MODULE / BRANCH 1. DC CIRCUIT IS ISOLATED AND INSULATED <br />FROM GROUND AND MEETS THE REQUIREMENT <br />OF NEC 690.35. <br />2. SUNPOWER PROVIDED CABLES COMES WITH <br />TWO (2) #12 AWG WIRE AND THIS IS BY <br />DESIGN. NEUTRAL AND ADDITIONAL GROUND <br />WIRE IS NOT REQUIRED FOR PROVIDED <br />TRUNK AND EXTENSION CABLES. <br />3. SUNPOWER AC MODULES HAVE BEEN TESTED <br />AND CERTIFIED TO UL 2703 FOR INTEGRATED <br />GROUNDING AND HENCE A SEPARATE GROUND <br />WIRE IS NOT REQUIRED WITHIN THE ARRAY. <br />4. USE ROW-TO-ROW GROUNDING CLIP <br />PROVIDED TO GROUND ROWS OF MODULE. <br />BOND SUB-ARRAYS BY RUNNING #6 AWG <br />BARE CU WIRE AND GROUND LUGS AT A <br />SINGLE POINT ON EACH SUB-ARRAY AND THEN <br />TO THE JUNCTION BOX. REFER TO PVE-4 FOR <br />ADDITIONAL DETAILS. <br />1. PROPER LISTING EXPECTED FOR CONDITIONS <br />OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. <br />2. ALL CONDUIT BEND RADII TO CONFORM TO <br />THE NEC MINIMUM BEND RADII <br />REQUIREMENTS. <br />3. MINIMUM CLEARANCE SHALL BE MAINTAINED <br />PER NEC FOR ALL NEW EQUIPMENT TO BE <br />INSTALLED. <br />4. EXISTING GROUNDING ELECTRODE SYSTEM <br />MUST MEET NEC AND LOCAL UTILITY <br />REQUIREMENTS. <br />5. COPPER CONDUCTORS SHALL BE USED <br />UNLESS SPECIFIED. <br />6. TYPE NM (ROMEX) CONDUCTORS ARE <br />ALLOWED FOR INTERNAL AND ATTIC RUNS <br />AND SHALL BE INSTALLED MEETING NEC <br />REQUIREMENTS. <br />7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, <br />IT WILL BE PERMITTED AND INSTALLED BY <br />3RD PARTY. <br />8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP <br />EXCEEDS 2%. <br />9. RUN CONDUCTORS IN EXISTING CONDUIT <br />WHEN AVAILABLE PROVIDED IT HAS NO <br />OTHER CONDUCTORS RUNNING THROUGH IT. <br />10. EQUIVALENT SPECIFICATION ON CABLES AND <br />ELECTRICAL EQUIPMENT SPECIFIED ARE <br />ACCEPTABLE. <br />11. AS DC POWER IS INTERNAL TO THE MODULE, <br />GROUNDING ELECTRODE CONDUCTOR (GEC) <br />FOR THE MODULE OR ARRAY IS NOT <br />REQUIRED. <br />AC MODULES NOTESELECTRICAL NOTES <br />PV CERTIFICATIONS AND COMPLIANCE <br />· UL 1741 / IEEE-1547 <br />· UL 1741 AC MODULE (TYPE 2 FIRE RATED) <br />· UL 62109-1 / IEC 62109-2 <br />· UL LISTED PV RAPID SHUTDOWN EQUIPMENT <br />ENABLES INSTALLATION IN ACCORDANCE WITH: <br />· NEC 690.6 (AC MODULE) <br />· NEC 690.12 RAPID SHUTDOWN (INSIDE AND <br />OUTSIDE THE ARRAY) <br />· NEC 690.15 AC CONNECTORS, 690.33(A)–(E)(1) <br />SUNPOWER PROVIDED AC MODULES EXTENSION <br />CABLE, LISTED AS AN ASSEMBLY <br />MODEL: SPR-M-435-H-AC (240) | QTY: 12 <br />MODEL: SPR-M-435-H-AC (240) [SI] | QTY: 12 <br />CONSUMPTION CT : CATEGORY 4 - SIMPLE - <br />PARALLEL SET - BUNDLING OF CONDUCTORS <br />PROJECT <br />INSTALLER <br />1 <br />4 <br /> <br />1 <br /> <br />4 <br /> <br /> <br />H <br />A <br /> <br />R <br /> <br />B <br /> <br />O <br /> <br />U <br /> <br />R <br /> <br /> W <br /> <br />A <br /> <br />Y <br /> <br /> S <br /> <br />O <br /> <br />U <br /> <br />T <br /> <br />H <br />R <br />I <br /> <br />C <br /> <br />H <br /> <br />M <br /> <br />O <br /> <br />N <br /> <br />D <br /> <br />, <br /> <br /> C <br /> <br />A <br /> <br /> <br /> <br />9 <br />4 <br /> <br />8 <br /> <br />0 <br /> <br />4 <br />( <br />5 <br /> <br />1 <br /> <br />0 <br /> <br />) <br /> <br /> 5 <br /> <br />4 <br /> <br />0 <br /> <br />- <br /> <br />0 <br /> <br />5 <br /> <br />5 <br /> <br />0 <br />C <br />O <br /> <br />R <br /> <br />P <br /> <br />O <br /> <br />R <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />, <br /> <br /> <br /> <br />S <br />Y <br /> <br />S <br /> <br />T <br /> <br />E <br /> <br />M <br /> <br />S <br />R E V I S I O N S <br />SO <br />L <br />A <br />R <br /> <br />I <br />N <br />D <br />I <br />V <br />I <br />D <br />U <br />A <br />L <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />REV DESCRIPTION DATE DB <br />DRAWN BY: <br />DATE DRAWN <br />SCALE <br />1 MPU TO 225A/200A 04/18/2023 SS <br />J <br />E <br />F <br />F <br />R <br />E <br />Y <br /> <br />K <br />A <br />H <br />N <br />32 <br />0 <br />2 <br /> <br />S <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />RP-368636 <br />5. <br />2 <br />2 <br /> <br />k <br />W <br /> <br />SPRI - ANAHEIM <br />11-09-2022 <br />A.KHAN <br />AZAM KHAN <br />SHEET <br />NTS <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br />- <br />L <br />I <br />N <br />E <br /> <br />D <br />I <br />A <br />G <br />R <br />A <br />M <br />& <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />PVE-1 <br />1 <br />3202 S Center St <br />05/04/23