Laserfiche WebLink
15A, 1P <br />HD <br />YES <br />14 <br />(1) #14 THHN <br />(1) #14 THHN EGC <br />MODEL: <br />LOCATION: <br />FIRST ALERT - HD6135FB <br />ON CEILING DIRECTLY <br />ABOVE ESS ENCLOSURE <br />NO <br />NONO <br />EGC: Bare CU #6 <br />BRANCH CIRCUIT <br />FROM PV ARRAY TO <br />JUNCTION BOX <br />#12 2 <br />A -- <br />1 <br />B <br />JUNCTION BOX, <br />NEMA-4 <br />THWN-2 <br />EGC: THWN-2 1 <br />2 <br />B <br />3 <br />#10 <br />#10 <br />EMT 3/4" <br />#10 <br />CONDUCTOR / CONDUIT SCHEDULE <br />DESCRIPTION & <br />CONDUCTOR TYPE <br />CONDUCTOR SIZE <br />(AWG)CONDUIT/CABLE TYPE CONDUIT SIZENUMBER OF <br />CONDUCTORS <br />1 <br />ROOFTOP <br />ARRAY WIRING A <br />DC <br />AC Branch Circuit #1AC <br />8 AC MODULES <br />TAG <br />BRANCH BREAKER <br />TYPE HOM2100 <br />60A, 2P <br />H <br />(E) UTILITY <br />BIDIRECTIONAL <br />METER #: <br />222012-762150 <br />EXISTING <br />GROUND <br />THWN-2 <br />EGC: THWN-2 1 <br />3 <br />EMT 1" <br />#3 <br />#8 <br />MI <br />D <br />ETHERNET <br />CONNECTION <br />TO DSL/CABLE <br />MODEM <br />CA <br />T <br />5 <br />e <br />PVS6 <br />BACKUP BUS (200A MAX) <br /> (N) HUB+ <br />200A, 120/240 V, NEMA-3R <br />MODEL: <br />GE <br />N <br />E <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />B <br />U <br />S <br />(1 <br />2 <br />5 <br />A <br /> <br />M <br />A <br />X <br />) <br />10 <br />YES <br />LOCATION: <br />**PVS6 <br />**BREAKERS ARE FIELD INSTALLED. <br />BREAKER RATING MAY VARY FROM 15A OR 20A <br />SV-HUB-01-C <br />C <br />C <br />OUTSIDE <br />MLO <br /> GROUNDED (INCLUDE GEC) UNGROUNDEDü <br />INSTALLATION NOTES <br />1 <br />CHECK BOX FOR WHETHER SYSTEM IS GROUNDED <br />OR UNGROUNDED: <br />FOR UNGROUNDED SYSTEMS: <br />· DC OCPD DISCONNECT BOTH CONDUCTORS OF <br />EACH SOURCE CIRCUIT. <br />· UNGROUNDED CONDUCTORS MUST BE <br />IDENTIFIED PER NEC 210.5(C). WHITE FINISHED <br />CONDUCTORS ARE NOT PERMITTED. <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />DC / DC CONVERTERS NO <br />SOURCE CIRCUIT JUNCTION BOX <br />SUNVAULT ESS <br />SUNVAULT BATTERY INVERTER <br />SOLAR LOAD CENTER <br />PV PRODUCTION METER <br />SEPARATE AC DISCONNECT <br />HEAT DETECTOR <br />YES <br />NO <br />11 <br />13 <br />BACK UP LOAD CENTER <br />NON-BACK UP LOAD CENTER <br />EV SUPPLY EQUIPMENT <br />NO <br />TAG DESCRIPTION <br />12 <br />REMOTE POWER OFF SWITCH <br />14 <br />HUB+ <br />INCOMING SOURCE FEED <br /> , 120/240 V, 1 PH, 3 W <br />LOCATION: <br />MANUF: <br />GND <br />TOP FED <br />MCB <br />GND <br />200A, 2P <br />100A,2P <br />225A <br />EXTERIOR WALL <br />SQUARE D <br />(E) MAIN SERVICE PANEL <br />THE DESIGNED INTERCONNECTION MEETS <br />NEC 705.12(B)(3)(3) REQUIREMENTS <br />1 PV MODULE <br />MICROINVERTER (FIELD-INSTALLED) <br />MISOLAR / BRANCH 1. PROPER LISTING EXPECTED FOR CONDITIONS <br />OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. <br />2. ALL CONDUIT BEND RADII TO CONFORM TO <br />THE NEC MINIMUM BEND RADII <br />REQUIREMENTS. <br />3. MINIMUM CLEARANCE SHALL BE MAINTAINED <br />PER NEC FOR ALL NEW EQUIPMENT TO BE <br />INSTALLED. <br />4. EXISTING GROUNDING ELECTRODE SYSTEM <br />MUST MEET NEC AND LOCAL UTILITY <br />REQUIREMENTS. <br />5. COPPER CONDUCTORS SHALL BE USED <br />UNLESS SPECIFIED. <br />6. TYPE NM (ROMEX) CONDUCTORS ARE <br />ALLOWED FOR INTERNAL AND ATTIC RUNS <br />AND SHALL BE INSTALLED MEETING NEC <br />REQUIREMENTS. <br />7. IF MAIN SERVICE PANEL IS TO BE UPGRADED, <br />IT WILL BE PERMITTED AND INSTALLED BY <br />3RD PARTY. <br />8. AC WIRING SHALL UPSIZE IF VOLTAGE DROP <br />EXCEEDS 2%. <br />9. RUN CONDUCTORS IN EXISTING CONDUIT <br />WHEN AVAILABLE PROVIDED IT HAS NO <br />OTHER CONDUCTORS RUNNING THROUGH IT. <br />10. EQUIVALENT SPECIFICATION ON CABLES AND <br />ELECTRICAL EQUIPMENT SPECIFIED ARE <br />ACCEPTABLE. <br />ELECTRICAL NOTES <br />SUNPOWER PROVIDED MICROINVERTER <br />EXTENSION CABLE, LISTED AS AN ASSEMBLY <br />MAKE/MODEL: ENPHASE IQ7HS-66-M-US [240] | QTY: 20 <br />MAKE/MODEL: WAAREE ENERGIES LIMITED WSMDI-400 | QTY: 20 <br />ENERGY STORAGE SYSTEM <br />MODEL: <br />6 <br />YES <br />YES <br />6.5 kWh <br />BATTERY <br />6.5 kWh <br />BATTERY <br />5 <br />(3) #8 THWN <br />(1) #10 THWN EGC <br />(3) #12 COMM. CABLES <br />19.5 kWh, 6.8 kW SUNVAULT <br />6.5 kWh <br />BATTERY <br />INVERTER <br />DC <br />AC <br />LOCKABLE <br />INTEGRATED <br />AC <br />DISCONNECT <br />40A, 2P <br />SV-BASE19.5-C <br />TO <br />(E)LOADS <br />NO <br />NO <br />**GRID SENSE <br />IN ESS NO <br />N <br />- <br />B <br />A <br />C <br />K <br />U <br />P <br /> <br />B <br />U <br />S <br /> <br />(1 <br />2 <br />5 <br />A <br /> <br />M <br />A <br />X <br />) <br /> <br />TO <br />(E) LOADS <br />NO <br />· RELOCATE APPROPRIATE BREAKERS FROM (E) <br />MSP TO APPROPRIATE PANELS OF (N) HUB+. <br />·INSTALL (N) 100A, 2P SUB FEED BREAKER IN <br />THE (E) MSP AND FEED (N) HUB+ WITH THIS <br />BREAKER. <br />·THE SITE CONSUMPTION CTS INSIDE THE HUB+ <br />MUST BE REMOVED AND PLACED UPSTREAM <br />FROM THE POINT OF INTERCONNECTION. <br />·INSTALL (N) HUB+ ON THE EXTERIOR WALL <br />·INSTALL (N) ESS INSIDE GARAGE <br />·LEAVE THE FOLLOWING LOAD/S IN MSP: <br />(E) 60A, 2P EV CHARGER, (E) 40A, 2P PV SOLAR <br />BREAKER <br />·INSTALL (N) SAFETY BOLLARD <br />·INSTALL (N) HEAT DETECTOR SINCE ESS IS <br />LOCATED INSIDE GARAGE <br />·EXISTING PV SOLAR BREAKER IS NON-SPWR <br />MODULES <br />·QUAD/TWIN BREAKERS REQUIRED <br />·CTS ARE COMPATIBLE WITH THIS INSTALLATION <br />·SEE PVE-6 FOR DETAILS. <br />50A, 2P <br />TO (E) SUBPANEL <br />40A, 2P <br />(E) EV <br />CHARGER <br />(E) PV SOLAR <br />BREAKER <br />TRENCHING REQUIRED <br />(TRANSITION TO EMT <br />WHERE NECESSARY) <br />D <br />THWN-2 <br />EGC: THWN-2 1 <br />3 <br />SCH 40 PVC 1" <br />#8 <br />#10 <br />D <br />YES <br />JUNCTION BOX, <br />NEMA-4 <br />3 <br />DC <br />AC Branch Circuit <br />ROOFTOP <br />ARRAY WIRING A <br />9 <br />LOCATED OUTSIDE <br />TRENCHING REQUIRED <br />(TRANSITION TO EMT <br />WHERE NECESSARY) <br />WITH VISIBLE KNIFE BLADES <br />#1010 AC MODULES <br />#1 <br />F <br />UTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC <br />EATON DG222URB OR EQUIVALENT <br />40A, 2P <br />YES <br />20A, 2P <br />E <br />(E) <br />(E) PV MODULE <br />· MANUF: <br />· MODEL: <br />· QTY: <br />(E) INVERTER <br />· MANUF: <br />· MODEL: <br />· QTY: <br />4.720 KW PV SYSTEM <br />CANADIAN SOLAR <br />CS6K-295MS <br />16 <br />ENPHASE <br />IQ6-60-2-US <br />16 <br />THWN-2 <br />EGC: THWN-2 1 <br />EMT 3/4" <br />#10 <br />#10 <br />4 <br />2THWN-2 <br />EGC: THWN-2 1 <br />SCH 40 PVC 1" <br />#8 <br />#10 <br />E <br />F <br />NOTE: <br />SEPARATE CONDUIT RUN WILL BE UTILIZED FOR THE <br />RELOCATED LOADS W/ CONSIDERATIONS TO AMPACITY <br />ADJUSTMENT FACTORS <br />LOAD LABEL BREAKER SIZE <br />RELOCATED LOADS FROM MSP TO (N) HUB+ <br />UNLABELED 20A, 1P <br />20A, 1P <br />20A, 1P <br />20A, 1P <br />20A, 1P <br />20A, 2P <br />20A, 1P <br />NUMBER OF CONDUCTORS/ <br />CONDUCTOR SIZE (AWG) <br />(1)#10 + (1)#10 EGC <br />(1)#10 + (1)#10 EGC <br />(1)#10 + (1)#10 EGC <br />(1)#10 + (1)#10 EGC <br />(1)#10 + (1)#10 EGC <br />(1)#10 + (1)#10 EGC <br />(2)#10 + (1)#10 EGC <br />20A, 1P (1)#10 + (1)#10 EGC <br />UNLABELED <br />UNLABELED <br />UNLABELED <br />UNLABELED <br />UNLABELED <br />KITCHEN FRIDGE <br />OUTLETS <br />MASTER BED <br />PLUG LITES <br />(2)#10 + (1)#10 EGC15A, 2PKITCHEN LITES <br />FAMILY RM <br />(2)#10 + (1)#10 EGC50A, 2P(E) SUBPANEL <br />(2)#10 + (1)#10 EGC50A, 2P(E) OVEN RANGE <br />· MANUF: <br />· MODEL: <br />· LOCATION: <br />ENPHASE <br />--- <br />NEAR MSP <br />SQUARE D <br />DU222RB, 60A <br />NEAR MSP <br />(E) NON-FUSED AC DISCONNECT <br />(E) SOLAR/COMBINER PANEL <br />· MANUF: <br />· RATING: <br />· LOCATION: <br /> (N) LOAD CENTER <br /> MIN., 120/240 V, NEMA-3R <br />LOCATION: <br />GND <br />7 <br />20A, 2P <br />20A, 2P <br />DETACHED GARAGE <br />100A <br />DC <br />AC Branch Circuit <br />#102 AC MODULES <br />#2 <br />MLO F <br />1 <br />4 <br /> <br />1 <br /> <br />4 <br /> <br /> <br />H <br />A <br /> <br />R <br /> <br />B <br /> <br />O <br /> <br />U <br /> <br />R <br /> <br /> W <br /> <br />A <br /> <br />Y <br /> <br /> S <br /> <br />O <br /> <br />U <br /> <br />T <br /> <br />H <br />R <br />I <br /> <br />C <br /> <br />H <br /> <br />M <br /> <br />O <br /> <br />N <br /> <br />D <br /> <br />, <br /> <br /> C <br /> <br />A <br /> <br /> <br /> <br />9 <br />4 <br /> <br />8 <br /> <br />0 <br /> <br />4 <br />( <br />5 <br /> <br />1 <br /> <br />0 <br /> <br />) <br /> <br /> 5 <br /> <br />4 <br /> <br />0 <br /> <br />- <br /> <br />0 <br /> <br />5 <br /> <br />5 <br /> <br />0 <br />C <br />O <br /> <br />R <br /> <br />P <br /> <br />O <br /> <br />R <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />, <br /> <br /> <br /> <br />S <br />Y <br /> <br />S <br /> <br />T <br /> <br />E <br /> <br />M <br /> <br />S <br />R E V I S I O N S <br />SO <br />L <br />A <br />R <br /> <br />I <br />N <br />D <br />I <br />V <br />I <br />D <br />U <br />A <br />L <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />GR <br />I <br />D <br />- <br />T <br />I <br />E <br />D <br /> <br />P <br />H <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />REV DESCRIPTION DATE DB <br />DRAWN BY: <br />PROJECT <br />DATE DRAWN <br />SCALE <br />PE <br />G <br />G <br />Y <br /> <br />S <br />H <br />A <br />C <br />K <br />E <br />L <br />F <br />O <br />R <br />D <br />12 <br />2 <br />2 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />S <br />Y <br />C <br />A <br />M <br />O <br />R <br />E <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />RP-467399 <br />8. <br />0 <br />0 <br /> <br />k <br />W <br />- <br />D <br />C <br />01-28-2024 <br />G. Perez <br />GRACE PEREZ <br />C <br />A <br /> <br /> <br />L <br />I <br /> <br />C <br /> <br />E <br /> <br />N <br /> <br />S <br /> <br />E <br /> <br /> C <br />- <br />1 <br />0 <br />, <br /> <br />B <br /> <br /> # <br /> <br />8 <br /> <br />9 <br /> <br />0 <br /> <br />8 <br /> <br />9 <br /> <br />5 <br />C <br />A <br /> <br /> <br />L <br />I <br /> <br />C <br /> <br />E <br /> <br />N <br /> <br />S <br /> <br />E <br /> <br /> C <br />- <br />1 <br />0 <br />, <br /> <br />B <br /> <br /> # <br /> <br />8 <br /> <br />9 <br /> <br />0 <br /> <br />8 <br /> <br />9 <br /> <br />5 <br />(N <br />) <br /> <br />1 <br />9 <br />. <br />5 <br /> <br />k <br />W <br />h <br /> <br />S <br />U <br />N <br />V <br />A <br />U <br />L <br />T <br /> <br />E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br />- <br />L <br />I <br />N <br />E <br /> <br />D <br />I <br />A <br />G <br />R <br />A <br />M <br />& <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br />NTS <br />SHEET <br />E-1 <br />Power back feeds are utilizing "Sum of Breakers" <br />rule. A placard must be attached to the main panel <br />indicating that the SUM OF ALL BREAKERS MUST <br />BE 225A OR LESS". CEC 705.12(B)(3)(3) <br />1222 S Sycamore St - <br />201824905/3/2024