My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1626 E Trinidad Way - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Trinidad Way
>
1626 E Trinidad Way
>
1626 E Trinidad Way - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2025 7:40:45 AM
Creation date
6/9/2025 7:40:28 AM
Metadata
Fields
Template:
Plan
Permit Number
20178395
101113430
Full Address
1626 E Trinidad Way
Document Relationships
101113430 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Trinidad Way\1626 E Trinidad Way
20178395 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Trinidad Way\1626 E Trinidad Way
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />12/14/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS TRIPLETT JR, STANLEY <br />1626 TRINIDAD WAY, <br />(714) 679-1808 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92701 <br />PV-5 <br />SINGLE LINE DIAGRAM <br />NOTES: <br />· CONDUTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. <br />· SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. <br />· ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. <br />· ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR <br /> SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. <br />· ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM <br /> MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. <br />· SOLAREDGE OPTIMIZERS ARE TO BE BONDED TO RACKING BY USING EITHER AN OPTIMIZER ATTACHMENT KIT <br /> OR A SOLAREDGE GROUNDING PLATE. (SEE SPEC SHEETS). <br />· ALL CONDUCTORS SHALL BE COPPER. <br />· ALL ROOFTOP RACEWAYS SHALL BE INSTALLED A>=7/8" ABOVE ROOF. <br />· INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS <br />CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG <br />NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG <br />NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS <br />USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. <br />11.060 kW (DC) SOLAR ARRAY: <br />(28) JA SOLAR JAM54S31-395/MR/1500V MODULES WITH <br />(28) SOLAREDGE POWER OPTIMIZERS: S440 WITH <br />(1) SOLAREDGE WAVE 7.6KW INVERTER: SE7600H-US (240V) [SI1-JUN20] <br />(1) STRING OF (15) MODULES & (1) STRING OF (13) MODULES <br />3/4" EMT OR EQUIVALENT (ON ROOF, UNDER EAVES) <br />(4) #10 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 GROUND <br />CONDUCTORS EXPOSED TO FREE AIR <br />(4) #10 AWG PV-WIRE 600V/RHW-2 <br />(1) #6 AWG BARE COPPER GROUND <br />WIRE IN CONDUIT CAN BE #8 AWG THWN-2 <br />3/4" EMT OR EQUIVALENT <br />(2) #8 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 NEUTRAL <br />(1) #8 AWG THWN-2 GROUND <br />AC DISCONNECT <br />(WITHIN 10' OF MSP) <br />NEMA <br />TYPE 3R <br />UL LISTED <br />JUNCTION <br />BOX <br />AR-01, AR-02, AR-03 & AR-04 <br />(28) JA SOLAR JAM54S31-395/MR/1500V <br />MODULES IN (1) STRING OF (15) MODULES <br />& (1) STRING OF (13) MODULES AT (18°) <br />PITCH AND (90°, 180°, 270° & 360°) <br />ORIENTATION <br />AC OUT <br />DC IN <br />NOTE: INTEGRATED DC DISCONNECT IS <br />INSTALLED WITH RAPID SHUTDOWN <br />DEVICE BY MANUFACTURER IN <br />COMPLIANCE WITH NEC 690.12. <br />(28) SOLAREDGE: S440 <br />DC OPTIMIZERS <br />NEW SQUARE D <br />DU222RB <br />60A, 240V, 2P <br />NON-FUSED, <br />NEMA 3R ENCLOSURE <br />(OR EQUIV.) <br />SOLAREDGE TECHNOLOGIES: <br />SE7600H-US (240V) [SI1-JUN20] <br />GRID TIED 2-POLE 7600 WATTS <br />INVERTER AC MAX OUTPUT <br />CURRENT OF 32A <br />MAX OUTPUT CURRENT 34.56A <br />1.56 <br />MULTIPLE CONDUCTOR FACTOR 1.0 <br />TEMP CORRECTION FACTOR 0.71 <br />AMPACITY OF # WIRE (THWN-2 @ 90 °C) 55 <br />MAXIMUM AMPACITY <br />34.56A * 1.56 = A < 55A <br />CONTINUOUS DUTY AND HIGH <br />IRIDESCENCE FACTOR <br />DC AMPACITY CALCULATION <br />55 * 1.0 * 0.71 = A > 34.56A <br />ADJUSTED AMPACITY <br />INVERTER OUTPUT CURRENT 32A <br />CONTINUOUS DUTY FACTOR 1.25 <br />MULTIPLE CONDUCTOR FACTOR 1.0 <br />TEMP CORRECTION FACTOR 0.88 <br />AMPACITY OF #8 WIRE (USE 75°)50A <br />MAXIMUM AMPACITY <br />32A * 1.25 = 40.0A < 50A <br />ADJUSTED AMPACITY <br />INVERTER OCPD RATING <br />AC AMPACITY CALCULATION FOR 7.6KW INVERTER <br />50A * 0.88 = 44.0A > 32A <br />40A <br />8 A <br />53.91 <br />39.05 <br />(2) 5/8" X 8' GND RODS SPACED <br />6' (MIN.) APART IF NO UFER <br />200A <br />CENTER FED <br />HOME LOADS <br />40A <br />UTILITY <br />METER <br />POINT OF CONNECTION <br />(E) 200A <br />120-240V <br />UTILITY METER NO : <br />SCE 322010-012815 <br />1626 E Trinidad <br />Way01/25/23
The URL can be used to link to this page
Your browser does not support the video tag.