Laserfiche WebLink
SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />12/14/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS TRIPLETT JR, STANLEY <br />1626 TRINIDAD WAY, <br />(714) 679-1808 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />SANTA ANA, CA 92701 <br />PV-7 <br />PLACARDS <br /> WARNING <br /> WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE. <br />NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE NEC SECTION LOCATION OF LABEL LABEL TEXT AND APPERANCE <br />690.54 ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION <br />WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE <br />LOCATION AT THE DISCONNECTING MEANS AS A POWER <br />SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE <br />NOMINAL OPERATING AC VOLTAGE. <br />690.56(B) <br />690.4(D) <br />705.10 <br />A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED <br />AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN <br />APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR <br />DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER <br />SOURCE DISCONNECTING MEANS FOR THE BUILDING OR <br />STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR <br />DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR <br />DIRECTORY SHALL BE MARKED WITH THE WORDING <br />“C UTION: MULTIPLE SOURCES OF POWER͘” NY <br />POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH <br />RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL <br />COMPLY WITH 110.21(B). <br />690.13(B) <br />690.15 <br />705.20 <br />EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY <br />INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) <br />POSITION AND BE PERMANENTLY MARKED: <br />“PV SYSTEM DISCONNECT” <br />OR EQUIVALENT. <br />690.53 A PERMANENT READILY VISIBLE LABEL INDICATING THE <br />HIGHEST MAXIMUM DC VOLTAGE IN A PV SYSTEM, <br />CALCULATED IN ACCORDANCE WITH 690.7, SHALL BE <br />PROVIDED BY THE INSTALLER AT ONE OF THE THREE <br />LOCATIONS. <br />690.31 <br />(D)(2) <br />UNLESS THE PURPOSE IS EVIDENT, THE FOLLOWING WIRING <br />METHODS AND ENCLOSURES THAT CONTAIN PV SYSTEM DC <br />CIRCUIT CONDUCTORS SHALL BE MARKED: <br />(1) EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING <br />METHODS <br />(2) COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION <br />BOXES <br />(3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE <br />CONDUIT OPENINGS ARE UNUSED <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />WHERE ALL TERMINALS OF THE DISCONNECTING MEANS <br />MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING <br />SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE <br />DISCONNECTING MEANS. <br />690.13(B) <br />690.15(C) <br />705.12 <br />(B)(3)(2) <br />705.12 <br />(B)(3)(3) <br />690.56 (C) <br />A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE <br />DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED <br />BREAKER FROM THE INVERTER. <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />PERMANENT WARNING LABELS SHALL BE APPLIED TO <br />DISTRIBUTION EQUIPMENT <br />(2) A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL <br />LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH <br />THAT INCLUDES THIS WORDING. THE LABEL SHALL BE <br />REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A <br />MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED <br />BACKGROUND . <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT <br />LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION <br />TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN <br />APPROVED READILY VISIBLE LOCATION AND SHALL <br />INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION <br />DEVICES. THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF <br />A BUILDING WITH A ROOF AND SHALL INCLUDE THE <br />FOLLOWING WORDS: <br />THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN <br />BLACK ON YELLOW BACKGROUND, AND THE REMAINING <br />CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM <br />HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: 240 VOLTS <br />RAPI' SHUT'OWN SWIT&H <br />)OR SOLAR P 9 S<STEM <br /> WARNING <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. <br />TOTAL RATING OF ALL OVERCURRENT DEVICES <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />PHOTOVOLTAIC <br /> DC DISCONNECT <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />MAXIMUM DC VOLTAGE <br />OF PV SYSTEM <br />SOLAR PV DC CIRCUIT <br />PHOTOVOLTAIC POWER SOURCE <br />(1) BUILDING WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS WITH <br />BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND PV SYSTEM WITH NO <br />RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING EACH <br />DIFFERENT PV SYSTEM AND DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID <br />SHUTDOWN SWITCH IS OPERATED. <br />PHOTOVOLTAIC <br /> AC DISCONNECT <br />CAUTION: <br />MULTIPLE SOURCES OF POWER <br />WITH DISCONNECTS LOCATED AS SHOWN <br />N <br />TR <br />I <br />N <br />I <br />D <br />A <br />D <br /> <br />W <br />A <br />Y <br /> NE& LA%ELING RE4UIREMENTS <br />32 AMPS <br />MAIN SERVICE PANEL "YOU ARE HERE" <br />PV AC DISCONNECT SWITCH <br />PV DC DISCONNECT ON <br />INVERTER (NEAR MSP) <br />MSP <br /> J <br />B <br /> <br /> AC INV <br />1626 E Trinidad <br />Way01/25/23