Laserfiche WebLink
RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />17 <br />1 <br />1 <br /> <br />W <br />E <br />S <br />T <br /> <br />P <br />A <br />R <br />K <br /> <br />L <br />A <br />N <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />(7 <br />1 <br />4 <br />) <br /> <br />6 <br />7 <br />3 <br />- <br />7 <br />1 <br />5 <br />0 <br />BA <br />R <br />R <br />A <br />G <br />A <br />N <br />, <br /> <br />G <br />E <br />R <br />A <br />R <br />D <br />O <br />AP <br />N <br />: <br /> <br />1 <br />0 <br />1 <br />0 <br />5 <br />3 <br />1 <br />3 <br />DA <br />T <br />E <br />PV-6 <br />SY <br />S <br />T <br />E <br />M <br /> <br />S <br />I <br />G <br />N <br />A <br />G <br />E <br />SIGNAGE <br />SIGNAGE REQUIREMENTS: <br />-RED BACKGROUND <br />-WHITE LETTERING <br />-MINIMUM 3/8" LETTER HEIGHT <br />-ALL CAPITAL LETTERS <br />-ARIAL OR SIMILAR FONT, NON-BOLD <br />-REFLECTIVE WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT (DURABLE <br />ADHESIVE MATERIALS MUST MEET THIS <br />REQUIREMENT) <br />ADHESIVE FASTENED SIGNS: <br />-THE LABEL SHALL BE SUITABLE FOR THE <br />ENVIRONMENT WHERE IT IS INSTALLED. <br />-WHERE REQUIRED ELSEWHERE IN THE CODE, <br />ALL FIELD APPLIED LABELS, WARNINGS, AND <br />MARKINGS SHOULD COMPLY WITH ANSI Z535.4 <br />[CEC 110.21(B) FIELD MARKINGS]. <br />-ADHESIVE FASTENED SIGNS MAY BE <br />ACCEPTABLE IF PROPERLY ADHERED. VINYL <br />SIGNS SHALL BE WEATHER RESISTANT.CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />CAUTION: SOLAR CIRCUIT <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION DO <br />NOT RELOCATE THIS OVERCURRENT DEVICE <br />AC SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />WARNING - Electric Shock Hazard <br />No user serviceable parts inside <br />Contact authorized service provider for assistance <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />SOLAR PV SYSTEM <br />EQUIPMENT WITH RAPID <br />SHUTDOWN <br />TURN RAPID <br />SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION <br />TO SHUTDOWN <br />PV SYSTEM AND <br />REDUCE SHOCK <br />HAZARD IT THE <br />ARRAY <br />SOLAR <br />ELECTRIC <br />PV PANELS <br /> WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCED WITH DISCONNECTS AS SHOWN <br />LABEL LOCATION: <br />PER CEC 705.12(B)(2)(3)(B) <br />[OR (C) IF THE PANELBOARD IS RATED NOT LESS THAN <br />SUM OF AMPERE RATINGS OF ALL OVERCURRENT <br />DEVICES SUPPLYING IT] <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL 969 AS <br />STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT <br />REQUIRED), MIN 3/8" LETTER HEIGHT ARIAL OR SIMILAR FONT <br />NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, <br />PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS <br />OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, <br />690.13(B)). <br />LABEL LOCATION: <br />MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC/AC <br />CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT <br />LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS <br />AND ALL COMBINER/JUNCTION BOXES. <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(B)(3-4)). <br />LABEL LOCATION: <br />SERVICE DISCONNECT MEANS <br />(PER CODE: CEC 690.56(C)(1)(A)). <br />LABEL LOCATION: <br />RAPID SHUTDOWN OR ON INVERTER IF RSD IS <br />INTEGRATED CEC 690.56(C)(3). <br />LABEL LOCATION: <br />UTILITY DISCONNECT <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC <br />DISCONNECT <br />(PER CODE: CEC 690.13 & CEC 690.13) <br />LABEL LOCATION: <br />INVERTER, JUNCTION BOXES (ROOF), AC <br />DISCONNECT <br />(PER CODE: CEC 690.13 & CEC 690.13) <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER <br />(PER CODE: CEC 690.13(B)) <br />[TO BE USED WHEN INVERTER IS UNDERGROUND] <br />LABEL LOCATION: <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />(PER CODE: CEC 690.53) <br />LABEL LOCATION: <br />WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO <br />WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3/8" LETTER <br />HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE <br />DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS <br />OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC 690.12, 690.56(C)). <br />WEATHER RESISTANT PLASTIC PLACARD <br />PLACEMENT: <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />WARNING <br />IF A GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />LABEL LOCATION: <br />AC DISCONNECT <br />(PER CODE: CEC 690.54) <br />LABEL LOCATION: <br />ALL BATTERIES AND/OR INVERTERS <br />(PER CODE: CEC 690.5) <br />ELECTRIC SHOCK HAZARD <br />WARNING <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />PHOTOVOLTAIC SYSTEM AC <br />DISCONNECT <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND PV <br />SOLAR ELECTRIC SYSTEM <br />OPERATING VOLTAGE <br />OPERATING CURRENT AMPS <br />VOLTS <br />LABEL LOCATION: <br />DC DISCONNECT, INVERTER, POINT OF <br />INTERCONNECTION <br />(PER CODE: CEC 690.54) <br />MAX SYSTEM VOLTAGE <br />MAX CIRCUIT CURRENT <br />MAX RATED DC/DC <br />OUTPUT CURRENT <br />AMPS <br />AMPS <br />VDC <br />DC DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />1711 N Park Ln- 101120149 & <br />20183458 <br />7/26/2024