CALL TOLL FREE 1 (800) 227-2600 <br />TWO WORKING DAYS BEFORE YOU DIG <br />REVISIONS <br />NO.DATE DESCRIPTION NO.DATE DESCRIPTION <br />CONTRACTOR: <br />CORONA CONSTRUCTION CO. <br />615 E. ALLEN AVE. <br />SAN DIMAS, CA 91773 <br />PHONE: 626-926-7487 <br />CA. LIC. #797455 CLASS A-B-HAZ C10 <br />EXPIRES 07/31/2025 <br />ELECTRICAL DETAILS <br />SITE ADDRESS: <br />UNITED PACIFIC #5669 <br />1913 WEST EDINGER AVE. <br />SANTA ANA, CA 92704 <br />SCALE: <br />DRAWN BY: <br />DATE: <br />JOB NO. <br />DRAWING NO. <br />CHECKED BY: <br />AS NOTED <br />ETHAN BUI <br />7/23/2023 <br />5669 <br />F9 <br />ALVARO CORONA <br />SHEET <br />F9 <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />B <br />A <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />21 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 <br />L <br />ICENSED CONTRACTOR <br />STATE OF CAL IFORNIA <br />CORONA CONSTRUCTION CO. <br />797455 <br />EXPIRES 07/31/2025 <br />TLS 350 <br />GUTTER <br />BOX <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />1 <br />/ <br />2 <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />3 <br />/ <br />4 <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />5 <br />/ <br />6 <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />7 <br />/ <br />8 <br />VE <br />N <br />T <br /> <br />S <br />U <br />M <br />P <br />MINI HYDROSTATIC <br />SENSOR 36 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />91 <br />DIESEL <br />VR <br />MINI HYDROSTATIC <br />SENSOR36 <br />FILL SUMP <br />VAC <br />J-BOX WITH <br />CORD GRIP ENTRIES <br />MONITOR PANEL TURBINE SUMP <br />POWER <br />12K GALLON DIESEL TANK <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />2 ZONE VACUUM <br />SENSOR WITH <br />MOUNTING KIT <br />74 <br />VACUMM SOURCE FROM <br />TURBINES' SIPHON CHECK <br />VALVE PORT <br />TURBINE SIPHONE <br />CHECK VALVE <br />VAC <br />VACVAC <br />VAC <br />PR <br />O <br />D <br />. <br /> <br />L <br />I <br />N <br />E <br />D D <br />VE <br />N <br />T <br />D VENT <br /> D <br /> <br />V <br />E <br />N <br />T <br />VR <br />VR <br />VR <br />91 <br />91 <br />91 <br />87 <br />87 <br />87 <br />QTY SENSOR / MAKE / MODEL LOCATION MODE <br />1 3 ZONE VACUUM SENSOR <br />VEEDER ROOT #330020-485 TANK #1 (87) <br />#1 - PRODUCT <br />#2 - VENT <br />#3 - VAPOR RETURN <br />1 2 ZONE VACUUM SENSOR <br />VEEDER ROOT #330020-480 TANK #2 (91)#1 - PRODUCT <br />#2 - VENT <br />1 2 ZONE VACUUM SENSOR <br />VEEDER ROOT #330020-480 TANK #3 (DIESEL)#1 - PRODUCT <br />#2 - VENT <br />NOTES <br />1.ALL VACUUM TUBING MUST BE VEEDER ROOT APPROVED VACUUM TUBING. <br />2.AN EXTERNAL SIPHON CHECK VALVE MUST BE USED WHEN MAKING A VACUUM SOURCE CONNECTION BETWEEN THE SCVS SYSTEM SENSORS <br />AND THE SIPHON PORT CARTRIDGE FOR ALL TURBINES. <br />3.DOUBLE WALL OF ALL PRODUCT, VENT, AND VAPOR RETURN PIPING TO BE VACUUM MONITORED. <br />4.DOUBLE WALL OF ALL TURBINE SUMP, FILL SUMP, UDC, AND VENT TRANSITION SUMP TO BE HYDROSTATIC MONITORED. <br />5.DOUBLE WALL OF ALL UST'S TO BE HYDROSTATIC MONITORED. <br />87 <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />MINI HYDROSTATIC <br />SENSOR36 <br />FILL SUMP <br />VAC VAC <br />J-BOX WITH <br />CORD GRIP ENTRIES <br />MONITOR PANEL TURBINE SUMP <br />POWER <br />12K GALLON 87 TANK <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />3 ZONE VACUUM <br />SENSOR WITH <br />MOUNTING KIT <br />16 <br />VACUMM SOURCE FROM <br />TURBINES' SIPHON CHECK <br />VALVE PORT <br />TURBINE SIPHONE <br />CHECK VALVE <br />VACVACVAC <br />VACVAC <br />VAC <br />3" OVER 2" FRP FOR <br />VEEDER ROOT TUBING <br />VACUUM MONITORING <br />PR <br />O <br />D <br />. <br /> <br />L <br />I <br />N <br />E <br />87 87 87 <br />VA <br />P <br />O <br />R <br /> <br />R <br />E <br />T <br />U <br />R <br />N <br />VE <br />N <br />T <br />VR <br />VENT <br />MINI HYDROSTATIC <br />SENSOR36 <br />FILL SUMP <br />VAC <br />J-BOX WITH <br />CORD GRIP ENTRIES <br />MONITOR PANEL TURBINE SUMP <br />POWER <br />12K GALLON 91 TANK <br />VACUMM SOURCE FROM <br />TURBINES' SIPHON CHECK <br />VALVE PORT <br />TURBINE SIPHONE <br />CHECK VALVE <br />VAC <br />VACVAC <br />PR <br />O <br />D <br />. <br /> <br />L <br />I <br />N <br />E <br />91 91 91 <br />VE <br />N <br />T <br />VENT <br />87 <br /> <br />V <br />E <br />N <br />T <br />87 <br /> <br />V <br />E <br />N <br />T <br />87 <br /> <br />V <br />E <br />N <br />T <br />91 <br /> <br />V <br />E <br />N <br />T <br />D <br />D <br />D <br />D <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />9 <br />/ <br />1 <br />0 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />UD <br />C <br /> <br />S <br />U <br />M <br />P <br /> <br />1 <br />1 <br />/ <br />1 <br />2 <br />MINI HYDROSTATIC <br />SENSOR 36 <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />VAPOR RETURN <br />91 <br />87 <br />VR <br />91 <br />87 <br />DIESEL <br />D <br />VR <br />91 <br />87 <br />VR <br />87 <br />VR <br />91 <br />87 <br />VR <br />91 <br />87 <br />VR <br />91 <br />87 <br />VAC <br />3-WAY RELIEF <br />BALL VALVE (TYP.) <br />57 <br />2 ZONE VACUUM <br />SENSOR WITH <br />MOUNTING KIT <br />74 <br />SIGNED 5/14/24 <br />1913 W Edinger Ave - <br />101118671 & 201824107/2/2024