Laserfiche WebLink
MP AC I <br />---- <br /> S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br /> <br />1 <br />9 <br />2 <br />5 <br /> <br />W <br /> <br />P <br />E <br />N <br />D <br />L <br />E <br />T <br />O <br />N <br /> <br />A <br />V <br />E <br />71 <br />4 <br /> <br />- <br /> <br />3 <br />7 <br />6 <br /> <br />- <br /> <br />4 <br />6 <br />9 <br />9 <br /> <br /> <br />E3 <br />SHEET NUMBER: <br />DRAWN BY: <br />DATE:8/30/22 <br /> T <br />R <br />I <br />N <br />H <br /> <br />T <br />H <br />I <br /> <br />L <br />E <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />Am <br />e <br />r <br />i <br />c <br />a <br />n <br /> <br />A <br />r <br />r <br />a <br />y <br /> <br />S <br />o <br />l <br />a <br />r <br /> 2 <br />0 <br />2 <br />1 <br /> <br />L <br />a <br />s <br /> <br />P <br />o <br />s <br />i <br />t <br />a <br />s <br /> <br />C <br />o <br />u <br />r <br />t <br /> # <br />1 <br />2 <br />9 <br /> <br />L <br />i <br />v <br />e <br />r <br />m <br />o <br />r <br />e <br /> <br />C <br />A <br /> <br />9 <br />4 <br />5 <br />5 <br />1 <br />84 <br />4 <br /> <br />3 <br />4 <br /> <br />S <br />O <br />L <br />A <br />R <br />Li <br />c <br /># <br />9 <br />9 <br />3 <br />4 <br />6 <br />7 <br /> <br />C <br />- <br />1 <br />0 <br /> <br />& <br /> <br />C <br />3 <br />9 <br />EXISTING HOUSE <br />SCALE: 1/16" = 1'-0" <br />PROPERTY PLAN <br />1925 W PENDLETON AVE <br />DRIVE WAY <br />PROPERTY LINE (N) MAIN SERVICE PANEL <br />(N) COMBINER BOX <br />(N) AC DISCONNECT <br />CONDUIT TO BE RUN INSIDE ATTIC WHERE ATTIC ACCESS AVAILABLE.WHERE <br />NO ATTIC ACCESS AVAILABLE CONDUIT TO BE RUN ON BLOCKS MIN. 1" ABOVE <br />ROOF SURFACE AND UNDER EAVES; CONDUIT TO BE PAINTED TO MATCH <br />EXTERIOR/EXISTING BACKGROUND COLOR OF ITS LOCATION; CONDUIT TO BE <br />LABELED AT MAX 10' INTERVALS. <br />CONDUIT RUN(S) AND JUNCTION BOX(S) LOCATIONS MAY CHANGE DUE TO FIELD <br />CONDITIONS. CONDUIT TO BE INSTALLED PER CRC R331.3 <br />Handled AC disconnect is required and "must" be <br />located within 8 feet of main service panel.No part of <br />the structure can be over 18" in height from the roof <br />without an Professional Engineer's stamp. No structure <br />may increase the height of the building by 10% of it's <br />original height. <br />FIRE SETBACKS REQUIRED: to the ridge on all sides <br />of each roof slope where panels/modules are located, <br />Fire department does not count the gable eaves as <br />part of the 3' fire pathway. 3' pathway must be <br />measured from the exterior bearing wall (applies FOR <br />2:12 ROOFS <br />NOTE: TO PROTECT EMT CONDUIT FROM <br />WEATHER CORROSION USE Paints approved for the <br />purpose. Zinc-rich paints or acrylic, urethane or <br />weather stable epoxy-based resins are frequently used. <br />Oil-based or alkyd paints should not be used. Surface <br />preparation is important for proper adherence. For best <br />results, the conduit / EMT should be washed, rinsed <br />and dried. It should not be abraded, scratched or <br />blasted since these processes could compromise the <br />protective zinc layer. A compatible paint primer or two <br />coats of paint adds protection <br />3' FIRE SETBACK ON VERY WELL <br />STRUCTURED AREA .WITH NO OVER HANG <br />( 23 ) (N)PANASONIC 380 INSTALLED FLUSHED ON <br />ROOF SURFACE WITH 180° AZ & 270° AZ AND 90°AZ <br />ROOF TILT 23° <br />433.09 FT² OVER SINGLE STORY HOUSE WITH <br />CLAY TILE ROOF . <br />7' <br />- <br />7 <br />" <br />5'-6" <br />3' <br />9'-8" <br />7' <br />- <br />1 <br />1 <br />" <br />5' <br />32 <br />' <br />- <br />3 <br />" <br />5' <br />1925 W Pendleton <br />Ave - 10111215712/16/22