Laserfiche WebLink
2. <br />5 <br />" <br />MI <br />N <br />61 <br />2" <br />MSPD INV <br />JB <br />1 <br />2 <br />3' <br />3' <br />1 '-6" <br />1 '- <br />6" <br />1'-6" <br />1 '-6 <br />" <br />1 <br />' <br />- <br />6 <br />" <br />1 '-6" <br />1 '-6" <br />3' <br />3' <br />278" <br />2.5" <br />MIN <br />SHEET TITLE <br />SHEET NUMBER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />LUNA <br />RESIDENCE <br />1 0.000 DC KW <br />9.1 95 KW CEC-AC RATING <br />STRING INVERTER SYSTEM <br />2045 <br />S GARNSEY ST <br />SANTA ANA, CA <br />92707 <br />CONTRACTOR <br />TITAN SOLAR POWER CA INC <br />525 W BASELINE ROAD <br />MESA, AZ 8521 0 <br />(855) 729-7652 <br />WWW.TITANSOLARPOWER.COM <br />PROJECT ID# TSP1 43470 <br />DATE DESCRIPTION <br />REVISION <br />DATE <br />DRAWN09-28-22 <br />DESIGN BY: RD <br />CAD <br />F O R C A L I I N C . <br />SHELLEY V CALUAG <br />cadforcali@gmail.com <br />323-698-4207 <br />SP: Ascend Energy <br />PROJECT NAME <br />A2 <br />MOUNTING <br />PLAN <br />58 TOTAL COMP SHINGLE <br />ATTACHMENTS <br />@ 4FT ON CENTER <br />SIDE VIEW <br />5/16"Ø SS LAG BOLT <br />2 LAGS PER <br />ATTACHMENT <br />2.5" MIN EMBEDMENT <br />ROOF <br />SHEATING <br />EXISTING ROOF <br />ECURB <br />FLASHING <br />MODULE <br />EVEREST <br />CROSSRAIL 48-X <br />END CLAMP <br />ASSEMBLY <br />EVEREST <br />T-FOOTX <br />(N) 3/4" EMT CONDUIT RUN <br />ABOVE ROOF OR UNDER <br />EAVES WHERE POSSIBLE <br />WIRING/CONDUIT RACEWAY <br /> WILL BE 7/8'' MINIMUM ABOVE THE <br />ROOFTOP PER CEC 31 0.1 5(B)(3)(C) <br />MOUNTING PLAN <br />SCALE: 3/32" = 1' <br />SOLAR PANEL DEAD WEIGHT CALCULATION <br />MODULE HANWHA Q CELLS <br />WIDTH (IN) LENGTH (IN) AREA (SQFT) WEIGHT (LBS) QTY <br />TOTAL <br />MODULE <br />AREA <br />TOTAL <br />MODULE <br />WEIGHT <br />41.1 74.00 21.12 48.50 25 528.02 1212.50 <br />RACKING IRONRIDGE <br />RACKING <br />WEIGHT <br />LBS/LNFT <br />MOUNTING <br />SYSTEM <br />WEIGHT <br />TOTAL <br />SYSTEM <br />WEIGHT <br />TOTAL <br />ATTACHMENT <br />POINTS <br />POINT <br />LOAD <br />CALCS <br />DISTRIBUTED LOAD <br />CALCULATION <br />.75 151.56 1364.06 64 21.31 2.58 PSF <br />NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 <br />ROOF COVERAGE <br />TOTAL <br />MODULE <br />AREA <br />ROOF FACE <br />AREA (SQFT) <br />ROOF <br />COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE <br />528.02 2296 23.00 23.00 </= 33% = OK <br />ROOF INFORMATION <br />ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS <br />RAFTERS AND/OR TRUSS RAFTER SPACING (IN)ATTACHMENT <br />SPACING <br />2 X 4 24" OC 48" OC <br />3F <br />T <br /> <br />F <br />I <br />R <br />E <br />PA <br />T <br />H <br />WA <br />Y <br />18" FIRE S <br />E <br />TBA <br />C <br />K <br />FIRE ACCESS POINT AREA <br />NOT TO BE OVER ANY <br />DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />B <br />(N) 25 - Q.PEAK DUO BLK ML-G10+ 400 <br />HANWHA Q CELL MODULES WITH <br />P401 SOLAREDGE OPTIMIZERS <br />STRING A - 13 MODULES <br />STRING B - 12 MODULES <br />LEGEND <br />(E) EXISTING <br />(N) NEW <br />(P) PROPOSED <br />CONDUIT RUN <br />VIF VERIFY IN FIELD <br />JUNCTION BOX <br />MAIN SERVICE PANEL <br />AC COMBINER <br />INVERTER <br />AC DISCONNECT <br />SUBPANEL <br />SOLAR METER <br />FIRE ACCESS POINTS <br />FIRE PATHWAY/SETBACKS <br />JB <br />MSP <br />D <br />SP <br />INV <br />AC <br />M <br />x <br />(N) SE7600H-US (240V) <br />SETAPP SOLAREDGE HD <br />INVERTER <br />(E) 125A MAIN SERVICE PANEL <br />SCE METER# 222013-165308 <br />(N) 60A AC DISCONNECT <br />FIRE ACCESS POINT AREA <br />NOT TO BE OVER ANY <br />DOORS, WINDOWS OR <br />OTHER OBSTRUCTIONS. <br />18" <br /> <br />FIRE S <br />E <br />TBA <br />C <br />K <br />18" FIRE SETBAC <br />K <br />18" FIRE SETBAC <br />K <br />B B B B <br />B <br />B <br />B <br />B <br />B <br />B <br />B <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A <br />A A A A <br />268° AZIMUTH <br />25° SLOPE <br />35 <br />9° <br />AZ <br />I <br />M <br />UT <br />H <br />25 <br />° <br />S <br />L <br />O <br />P <br />E <br />17 <br />9 <br />° <br />A <br />Z <br />I <br />M <br />U <br />T <br />H <br />25 <br />° <br />S <br />L <br />O <br />P <br />E <br />17 <br />9° <br /> <br />A <br />Z <br />I <br />M <br />U <br />TH <br />15 <br />° <br />S <br />L <br />O <br />PE <br />88° AZIMUTH <br />25° SLOPE <br />MODULE <br />SIDE VIEW <br />EVEREST <br />CROSSRAIL 44-X <br />EVEREST SPLICE <br />FOOT X <br />NOTE: <br />MODULES WILL BE INSTALLED <br />FLUSHED TO EXISTING ROOF SLOPE <br />END CLAMP <br />ASSEMBLY <br />EVEREST K2 SOLAR <br />SEAL BUTYL PAD <br />COMP SHINGLE ROOF <br />ATTACHMENT DETAIL <br />SCALE: 2" = 1'-0" <br />M5 X 60 LAG SCREWS <br />5/16" Ø <br />2 LAGS PER ATTACHMENT <br />2.5" MIN EMBEDMENT <br />6 TOTAL FLAT ROOF <br />ATTACHMENTS <br />@ 4FT ON CENTER <br />FLAT ROOF ATTACHMENT DETAIL <br />SCALE: 2" = 1'-0" <br />STRUCTURAL ONLY <br />www.vincise.com <br />S T R U C T U R A L E N G I N E E R S <br />11.7.2022 <br />2045 S Garnsey St <br />01/30/23