Laserfiche WebLink
DATASHEET <br />IQ System Controller 3/3G <br />The Enphase IQ System Controller 3/3G connects the home to grid power, the IQ Battery <br />system, and solar PV. It provides microgrid interconnect device (MID) functionality by <br />automatically detecting and seamlessly transitioning the home energy system from grid power <br />to backup power in the event of a grid failure. It consolidates interconnection equipment into a <br />single enclosure and streamlines grid-independent capabilities of PV and storage installations by <br />providing a consistent, pre-wired solution for residential applications. <br />Easy to install <br />• Connects to service entrance¹ or main <br />load center <br />• Includes neutral-forming transformer <br />• Mounts on single stud with centered <br />brackets <br />• Provides conduit entry from the <br />bottom, left, or right <br />• Includes color-coded wires for ease of <br />wiring the System Shutdown Switch <br />• Integrates hold-down functionality to <br />eliminate the need for hold-down kits <br />and special breakers <br />Flexible <br />• Can be used for Sunlight Backup, <br />Home Essentials Backup, or Full Energy <br />Independence <br />• IQ System Controller 3 integrates with <br />IQ Battery 5P <br />• IQ System Controller 3G integrates <br />with select AC standby generators. See <br />the Generator integration tech brief for <br />a list of generators <br />• Provides a seamless transition to <br />backup <br />Safe and reliable <br />• System Shutdown Switch can be <br />used to disconnect PV, battery, and <br />generator systems <br />• System Shutdown Switch acts as a <br />rapid shutdown initiator of grid-forming <br />IQ8 PV Microinverters for the safety <br />of maintenance technicians/first <br />responders <br />• 10-year limited warranty <br />(1) IQ System Controller 3 is not suitable for use as service equipment in Canada. <br />IQSC-3-DSH-00021-3.0-EN-US-2023-08-08 <br />Eas <br />© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at <br />https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. <br />Data subject to change. <br />IQ Combiner 5/5C <br />Consolidates PV interconnection equipment <br />into a single enclosure and streamlines IQ Series <br />Microinverters and IQ Gateway installation by <br />providing a consistent, pre-wired solution for <br />residential applications <br />IQ Series Microinverters <br />The high-powered smart grid-ready IQ Series <br />Microinverters (M Series, IQ6, IQ7, and IQ8 <br />Series) dramatically simplify the installation <br />process <br />10-year limited <br />warranty <br />IQ Load Controller <br />Helps prioritize essential appliances <br />during a grid outage to optimize <br />energy consumption and prolong <br />battery life <br />IQ Battery 5P <br />Fully integrated AC battery system. Includes six <br />field-replaceable IQ8D-BAT microinverters <br />(4) The IQ System Controller 3 is rated at 22 kAIC. <br />(5) Integrated hold-down kit support breakers (BR230/BR230/BR240) without predrilled hole. <br /> Integrated hold-down kit also supports GE/ABB and Siemens as mentioned under section alternate DER circuit breakers. <br />(6) "~" indicates alternating current (AC) supply. <br />(*) Power Control System. <br />IQ System Controller 3/3G <br />MODEL NUMBER DESCRIPTION <br />SC200D111C240US01 <br />IQ System Controller 3 streamlines the grid-independent capabilities of PV and storage <br />installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 40 kWH (without <br />PCS*) and 80 kWh (with PCS*). Does not support generator integration <br />SC200G111C240US01 <br />IQ System Controller 3G streamlines the grid-independent capabilities of PV and storage <br />installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 20 kWH (without <br />PCS*) and 40 kWh (with PCS*). Supports generator integration <br />WHAT'S IN THE BOX <br /> IQ System Controller 3/3G Includes neutral-forming transformer (NFT) and microgrid interconnect device (MID) <br /> System Shutdown Switch Includes pre-wired red, black, orange, and purple 12 AWG wire (EP200G-NA-02-RSD) <br /> Wall-mounting bracket Screws provided in the accessories kit for mounting <br /> 4-pole circuit breaker Pre installed Quad breaker (BRK-20A40A-4P-240V), 20 A-40 A, 10 kAIC, Eaton BQC2202402 <br /> Accessories kit IQ System Controller 3/3G literature kit, including labels, CTRL headers, screws, filler plates, and <br />Quick Install Guide (QIG) (EP200G-LITKIT) <br />OPTIONAL ACCESSORIES AND REPLACEMENT PARTS <br />CT-200-SPLIT 200 A split core current transformers for metering (accuracy: ±2.5%)³ <br />CT-200-CLAMP 200 A clamp-type current transformers for metering (accuracy: ±2.5%)³ <br />Main or load circuit breakers (order separately, as needed)4 <br />• BRK-100A-2P-240V : 2-pole, 100A, 25kAIC, CSR2100N or CSR2100 <br />• BRK-125A-2P-240V: 2-pole, 125A, 25kAIC, CSR2125N <br />• BRK-150A-2P-240V: 2-pole, 150A, 25kAIC, CSR2150N <br />• BRK-175A-2P-240V: 2-pole, 175A, 25kAIC, CSR2175N <br />• BRK-200A-2P-240V: 2-pole, 200A, 25kAIC, CSR2200N <br />Distributed energy resource (DER) circuit breakers (order separately, as <br />needed)5 <br />• BRK-20A-2P-240V-B: 2-pole, 20 A, 10 kAIC, BR220B/BR220 <br />• BRK-30A-2P-240V-B: 2-pole, 30 A, 10 kAIC, BR230 <br />• BRK-40A-2P-240V-B: 2-pole, 40 A, 10 kAIC, BR240B/BR240 <br />• BRK-60A-2P-240V: 2-pole, 60 A, 10 kAIC, BR260 <br />• BRK-80A-2P-240V: 2-pole, 80 A, 10 kAIC, BR280 <br />EP200G-HNDL-R1 IQ System Controller 3/3G installation handle kit (order separately) <br />CTRL-SC3-NA-01 Control cable, 500 ft. spool (order separately) <br />ALTERNATE DER CIRCUIT BREAKERS <br /> GE/ABB THQL21xx (20/40/60/80 A) <br /> Siemens Q2xx (20/40/60/80 A) <br /> Siemens (quad breaker) Q24020CT2 (20/40 A) <br />ELECTRICAL SPECIFICATIONS <br />Nominal voltage/Range (L-L)240 V~6/±20% <br />Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L) <br />Auxiliary (dry) contact for load control, excess PV control, and generator <br />two-wire control 24 V, 1 A <br />Nominal frequency/Range 60 Hz/56–63 Hz <br />Frequency measurement accuracy ±0.1 Hz <br />Maximum continuous current rating 160 A <br />Maximum input overcurrent protection device 200 A <br />Maximum output overcurrent protection device 200 A <br />Maximum overcurrent protection device rating for generator circuit 80 A (IQ System Controller 3G only - SC200G111C240US01) <br /> Maximum overcurrent protection device rating for storage circuit 2 x 80 A (IQ System Controller 3 - SC200D111C240US01), <br />1 x 80 A (IQ System Controller 3G - SC200G111C240US01 ) <br />DATASHEET <br />(2) Factory installed quad breaker (Siemens or Eaton). NFT pre-wired to 40 A terminal of the quad breaker. <br />(3) Two units of CT-200-SPLIT or CT-200-CLAMP must be bought separately for generator integration. <br />IQSC-3-DSH-00021-3.0-EN-US-2023-08-08 <br />2352 N Riverside <br />Dr1/23/2025