DATASHEET
<br />IQ System Controller 3/3G
<br />The Enphase IQ System Controller 3/3G connects the home to grid power, the IQ Battery
<br />system, and solar PV. It provides microgrid interconnect device (MID) functionality by
<br />automatically detecting and seamlessly transitioning the home energy system from grid power
<br />to backup power in the event of a grid failure. It consolidates interconnection equipment into a
<br />single enclosure and streamlines grid-independent capabilities of PV and storage installations by
<br />providing a consistent, pre-wired solution for residential applications.
<br />Easy to install
<br />• Connects to service entrance¹ or main
<br />load center
<br />• Includes neutral-forming transformer
<br />• Mounts on single stud with centered
<br />brackets
<br />• Provides conduit entry from the
<br />bottom, left, or right
<br />• Includes color-coded wires for ease of
<br />wiring the System Shutdown Switch
<br />• Integrates hold-down functionality to
<br />eliminate the need for hold-down kits
<br />and special breakers
<br />Flexible
<br />• Can be used for Sunlight Backup,
<br />Home Essentials Backup, or Full Energy
<br />Independence
<br />• IQ System Controller 3 integrates with
<br />IQ Battery 5P
<br />• IQ System Controller 3G integrates
<br />with select AC standby generators. See
<br />the Generator integration tech brief for
<br />a list of generators
<br />• Provides a seamless transition to
<br />backup
<br />Safe and reliable
<br />• System Shutdown Switch can be
<br />used to disconnect PV, battery, and
<br />generator systems
<br />• System Shutdown Switch acts as a
<br />rapid shutdown initiator of grid-forming
<br />IQ8 PV Microinverters for the safety
<br />of maintenance technicians/first
<br />responders
<br />• 10-year limited warranty
<br />(1) IQ System Controller 3 is not suitable for use as service equipment in Canada.
<br />IQSC-3-DSH-00021-3.0-EN-US-2023-08-08
<br />Eas
<br />© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at
<br />https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries.
<br />Data subject to change.
<br />IQ Combiner 5/5C
<br />Consolidates PV interconnection equipment
<br />into a single enclosure and streamlines IQ Series
<br />Microinverters and IQ Gateway installation by
<br />providing a consistent, pre-wired solution for
<br />residential applications
<br />IQ Series Microinverters
<br />The high-powered smart grid-ready IQ Series
<br />Microinverters (M Series, IQ6, IQ7, and IQ8
<br />Series) dramatically simplify the installation
<br />process
<br />10-year limited
<br />warranty
<br />IQ Load Controller
<br />Helps prioritize essential appliances
<br />during a grid outage to optimize
<br />energy consumption and prolong
<br />battery life
<br />IQ Battery 5P
<br />Fully integrated AC battery system. Includes six
<br />field-replaceable IQ8D-BAT microinverters
<br />(4) The IQ System Controller 3 is rated at 22 kAIC.
<br />(5) Integrated hold-down kit support breakers (BR230/BR230/BR240) without predrilled hole.
<br /> Integrated hold-down kit also supports GE/ABB and Siemens as mentioned under section alternate DER circuit breakers.
<br />(6) "~" indicates alternating current (AC) supply.
<br />(*) Power Control System.
<br />IQ System Controller 3/3G
<br />MODEL NUMBER DESCRIPTION
<br />SC200D111C240US01
<br />IQ System Controller 3 streamlines the grid-independent capabilities of PV and storage
<br />installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 40 kWH (without
<br />PCS*) and 80 kWh (with PCS*). Does not support generator integration
<br />SC200G111C240US01
<br />IQ System Controller 3G streamlines the grid-independent capabilities of PV and storage
<br />installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 20 kWH (without
<br />PCS*) and 40 kWh (with PCS*). Supports generator integration
<br />WHAT'S IN THE BOX
<br /> IQ System Controller 3/3G Includes neutral-forming transformer (NFT) and microgrid interconnect device (MID)
<br /> System Shutdown Switch Includes pre-wired red, black, orange, and purple 12 AWG wire (EP200G-NA-02-RSD)
<br /> Wall-mounting bracket Screws provided in the accessories kit for mounting
<br /> 4-pole circuit breaker Pre installed Quad breaker (BRK-20A40A-4P-240V), 20 A-40 A, 10 kAIC, Eaton BQC2202402
<br /> Accessories kit IQ System Controller 3/3G literature kit, including labels, CTRL headers, screws, filler plates, and
<br />Quick Install Guide (QIG) (EP200G-LITKIT)
<br />OPTIONAL ACCESSORIES AND REPLACEMENT PARTS
<br />CT-200-SPLIT 200 A split core current transformers for metering (accuracy: ±2.5%)³
<br />CT-200-CLAMP 200 A clamp-type current transformers for metering (accuracy: ±2.5%)³
<br />Main or load circuit breakers (order separately, as needed)4
<br />• BRK-100A-2P-240V : 2-pole, 100A, 25kAIC, CSR2100N or CSR2100
<br />• BRK-125A-2P-240V: 2-pole, 125A, 25kAIC, CSR2125N
<br />• BRK-150A-2P-240V: 2-pole, 150A, 25kAIC, CSR2150N
<br />• BRK-175A-2P-240V: 2-pole, 175A, 25kAIC, CSR2175N
<br />• BRK-200A-2P-240V: 2-pole, 200A, 25kAIC, CSR2200N
<br />Distributed energy resource (DER) circuit breakers (order separately, as
<br />needed)5
<br />• BRK-20A-2P-240V-B: 2-pole, 20 A, 10 kAIC, BR220B/BR220
<br />• BRK-30A-2P-240V-B: 2-pole, 30 A, 10 kAIC, BR230
<br />• BRK-40A-2P-240V-B: 2-pole, 40 A, 10 kAIC, BR240B/BR240
<br />• BRK-60A-2P-240V: 2-pole, 60 A, 10 kAIC, BR260
<br />• BRK-80A-2P-240V: 2-pole, 80 A, 10 kAIC, BR280
<br />EP200G-HNDL-R1 IQ System Controller 3/3G installation handle kit (order separately)
<br />CTRL-SC3-NA-01 Control cable, 500 ft. spool (order separately)
<br />ALTERNATE DER CIRCUIT BREAKERS
<br /> GE/ABB THQL21xx (20/40/60/80 A)
<br /> Siemens Q2xx (20/40/60/80 A)
<br /> Siemens (quad breaker) Q24020CT2 (20/40 A)
<br />ELECTRICAL SPECIFICATIONS
<br />Nominal voltage/Range (L-L)240 V~6/±20%
<br />Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L)
<br />Auxiliary (dry) contact for load control, excess PV control, and generator
<br />two-wire control 24 V, 1 A
<br />Nominal frequency/Range 60 Hz/56–63 Hz
<br />Frequency measurement accuracy ±0.1 Hz
<br />Maximum continuous current rating 160 A
<br />Maximum input overcurrent protection device 200 A
<br />Maximum output overcurrent protection device 200 A
<br />Maximum overcurrent protection device rating for generator circuit 80 A (IQ System Controller 3G only - SC200G111C240US01)
<br /> Maximum overcurrent protection device rating for storage circuit 2 x 80 A (IQ System Controller 3 - SC200D111C240US01),
<br />1 x 80 A (IQ System Controller 3G - SC200G111C240US01 )
<br />DATASHEET
<br />(2) Factory installed quad breaker (Siemens or Eaton). NFT pre-wired to 40 A terminal of the quad breaker.
<br />(3) Two units of CT-200-SPLIT or CT-200-CLAMP must be bought separately for generator integration.
<br />IQSC-3-DSH-00021-3.0-EN-US-2023-08-08
<br />2352 N Riverside
<br />Dr1/23/2025
|