My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2402 S Rene Dr - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Rene Dr
>
2402 S Rene Dr
>
2402 S Rene Dr - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2025 8:06:37 AM
Creation date
6/9/2025 8:06:15 AM
Metadata
Fields
Template:
Plan
Permit Number
20177812
101110773
101112582
Full Address
2402 S Rene Dr
Document Relationships
101110773 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Rene Dr\2402 S Rene Dr
101112582 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Rene Dr\2402 S Rene Dr
20177812 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Rene Dr\2402 S Rene Dr
Text box
ID:
1
Creator:
Import Agent
Created:
6/9/2025 8:06 AM
Modified:
5/30/2025 3:39 PM
Text:
http://www.q-cells.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DETAIL A 16 mm <br />8.5 mm21.25 mm <br />980 mm <br />1717 mm <br />4 × Mounting slots <br />(DETAIL A) <br />Frame <br />1045 mm <br />32 mm <br />8 × Drainage holes <br />368.5 mm <br />4 × Grounding points ø 4.5 mm <br />Label <br />≥ 1150 mm <br />≥ 1150 mm <br />1002.5 mm <br />RE <br />L <br />A <br />T <br />I <br />V <br />E <br /> <br />E <br />F <br />F <br />I <br />C <br />I <br />E <br />N <br />C <br />Y <br />CO <br />M <br />P <br />A <br />R <br />E <br />D <br /> <br />T <br />O <br /> <br />N <br />O <br />M <br />I <br />N <br />A <br />L <br /> <br />P <br />O <br />W <br />E <br />R <br /> <br /> [ <br />% <br />] <br />YEARS <br />Q CELLS <br />Industry standard for linear warranties* <br />*Standard terms of guarantee for the 10 PV companies <br />with the highest production capacity in 2014 (as at: September 2014) <br />100 <br />95 <br />90 <br />85 <br />80 <br />15 5 25200 10 <br />98 <br />86 <br /> 200 400 600 800 1000 <br />110 <br />100 <br />90 <br />80 <br />RE <br />L <br />A <br />T <br />I <br />V <br />E <br /> <br />E <br />F <br />F <br />I <br />C <br />I <br />E <br />N <br />C <br />Y <br /> <br />[ <br />% <br />] <br />IRRADIANCE [W/m²] <br />α [% / K]+0.04 β [% / K] −0.27 <br />γ [% / K]−0.34 NMOT [°C] 43 ± 3 <br />[V]1000 <br />[A]20 C / TYPE 2 <br />[Pa] 3600 / 2660 −40 °C - +85 °C <br />[Pa] 5400 / 4000 <br />350 355 360 365 370 <br />[W]350 355 360 365 370 <br />[A]10.97 11.00 11.04 11.07 11.10 <br />[V]41.11 41.14 41.18 41.21 41.24 <br />[A]10.37 10.43 10.49 10.56 10.62 <br />[V]33.76 34.03 34.31 34.58 34.84 <br />[%]≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 ≥ 20.6 <br />[W]262.6 266.3 270.1 273.8 277.6 <br />[A]8.84 8.87 8.89 8.92 8.95 <br />[V]38.77 38.80 38.83 38.86 38.90 <br />[A]8.14 8.20 8.26 8.31 8.37 <br />[V]32.24 32.48 32.71 32.94 33.17 <br />Hanwha Q CELLS GmbH <br />Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com <br />Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and <br />use of this product. <br />Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE <br />At least 98 % of nominal power dur- <br />ing first year. Thereafter max. 0.5 % <br />degradation per year. At least 93.5 % <br />of nominal power up to 10 years. At <br />least 86 % of nominal power up to <br />25 years. <br />All data within measurement toler- <br />ances. Full warranties in accordance <br />with the warranty terms of the <br />Q CELLS sales organisation of your <br />respective country. <br />Typical module performance under low irradiance conditions in <br />comparison to STC conditions (25 °C, 1000 W/m2). <br />Sp <br />e <br />c <br />i <br />f <br />i <br />c <br />a <br />t <br />i <br />o <br />n <br />s <br /> <br />s <br />u <br />b <br />j <br />e <br />c <br />t <br /> <br />t <br />o <br /> <br />t <br />e <br />c <br />h <br />n <br />i <br />c <br />a <br />l <br /> <br />c <br />h <br />a <br />n <br />g <br />e <br />s <br /> <br />© <br />Q <br /> <br />C <br />E <br />L <br />L <br />S <br /> <br />Q. <br />P <br />E <br />A <br />K <br /> <br />D <br />U <br />O <br /> <br />B <br />L <br />K <br />- <br />G <br />1 <br />0 <br />+ <br />_ <br />3 <br />5 <br />0 <br />- <br />3 <br />7 <br />0 <br />_ <br />2 <br />0 <br />2 <br />1 <br />- <br />0 <br />8 <br />_ <br />R <br />e <br />v <br />0 <br />1 <br />_ <br />E <br />N <br />PROPERTIES FOR SYSTEM DESIGN <br />Maximum System Voltage VSYS PV module classification Class II <br />Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 <br />Max. Design Load, Push / Pull Permitted Module Temperature <br />on Continuous DutyMax. Test Load, Push / Pull <br />ELECTRICAL CHARACTERISTICS <br />POWER CLASS <br />MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) <br />Mi <br />n <br />i <br />m <br />u <br />m <br />Power at MPP1 PMPP <br />Short Circuit Current1 ISC <br />Open Circuit Voltage1 VOC <br />Current at MPP IMPP <br />Voltage at MPP VMPP <br />Efficiency1 η <br />MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 <br />Mi <br />n <br />i <br />m <br />u <br />m <br />Power at MPP PMPP <br />Short Circuit Current ISC <br />Open Circuit Voltage VOC <br />Current at MPP IMPP <br />Voltage at MPP VMPP <br />1Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 <br />MECHANICAL SPECIFICATION <br />Format 1717 mm × 1045 mm × 32 mm (including frame) <br />Weight 19.9 kg <br />Front Cover 3.2 mm thermally pre-stressed glass with <br />anti-reflection technology <br />Back Cover Composite film <br />Frame Black anodised aluminium <br />Cell 6 × 20 monocrystalline Q.ANTUM solar half cells <br />Junction box 53-101 mm × 32-60 mm × 15-18 mm <br />Protection class IP67, with bypass diodes <br />Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm <br />Connector Stäubli MC4; IP68 <br />TEMPERATURE COEFFICIENTS <br />Temperature Coefficient of ISC Temperature Coefficient of VOC <br />Temperature Coefficient of PMPP Nominal Module Operating Temperature <br />QUALIFICATIONS AND CERTIFICATES <br />Quality Controlled PV - TÜV Rheinland; <br />IEC 61215:2016; IEC 61730:2016. <br />This data sheet complies <br />with DIN EN 50380. <br />QCPV Certification ongoing. <br />2402 S Rene Dr <br />11/03/22
The URL can be used to link to this page
Your browser does not support the video tag.