Laserfiche WebLink
MSP SLC UM CB <br />INV <br />~5 <br />8 <br />. <br />45 <br />' <br />~99.48' <br />~100.54' <br />~2 <br />1 <br />. <br />1 <br />0 <br />' <br />~3 <br />9 <br />. <br />0 <br />9 <br />' <br />18'-9" <br />12 <br />' <br />-5 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />21'-7" <br />JB <br />ACD <br />SITE PLAN WITH ROOF PLAN <br />SHEET NAME <br />SHEET NUMBER <br />PV-1 <br />PROJECT NAME <br />KI <br />M <br /> <br />QU <br />O <br />C <br /> <br />LE <br />52 <br />1 <br />6 <br /> <br />W <br />CR <br />Y <br />S <br />T <br />A <br />L <br /> <br />LN <br />, <br />SA <br />N <br />T <br />A <br /> <br />AN <br />A <br />, <br /> <br />CA <br />, <br /> <br />92 <br />7 <br />0 <br />4 <br /> <br />US <br />A <br />AP <br />N <br /># <br /> <br />10 <br />8 <br />5 <br />9 <br />1 <br />7 <br />8 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />SC <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR04/11/2023 INITIAL RELEASE <br />DESIGN SUPPORT DAY OF INSTALL: <br />CHAT.POWUR.COM <br />07/20/2023 REVISION A <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />NOTE: <br />3/4" OR GREATER EMT CONDUIT <br />RUN (7/8" ABOVE ROOF) <br />LEGEND <br />(E) POWER-ONE PVI-3.0-OUTD-S-US-A <br />INVERTER, (240V) <br />JUNCTION BOX <br />INV <br />JB <br />MSP MAIN SERVICE PANEL <br />GATE <br />FENCE <br />TREES <br />ENPHASE IQ COMBINER 4 <br />X2-IQ-AM1-240-4 (IEEE 1547:2018)CB <br />UTILITY METERUM <br />VENT, ATTIC FAN (ROOF OBSTRUCTION) <br />CHIMNEY <br />PROPERTY LINE <br />EXISTING <br />DRIVEWAY <br />W <br />C <br />R <br />Y <br />S <br />T <br />A <br />L <br /> <br />L <br />N <br />TWO - STORY <br />HOUSE <br />(E) 08 SUNPOWER SPR-X20-250-BLK <br />(250W) MODULES <br />(E) STRUCTURE <br />ROOF ACCESS POINT <br />ROOF ACCESS POINT <br />SLC SOLAR LOAD CENTER <br />A <br />A <br />ACD (E) AC DISCONNECT <br />6/30/2024 <br />STAMPED 07/21/2023 <br />STRUCTURAL NOTES : <br />1. THESE PLANS ARE STAMPED FOR <br />STRUCTURAL CODE COMPLIANCE OF THE <br />ROOF FRAMING SUPPORTING THE PROPOSED <br />PV INSTALLATION ONLY. <br />2. THESE PLANS ARE NOT STAMPED FOR <br />WATER LEAKAGE. <br />3. PV MODULES, RACKING, AND ATTACHMENT <br />COMPONENTS MUST FOLLOW <br />MANUFACTURER GUIDELINES AND <br />REQUIREMENTS. <br />4. PLEASE SEE THE ACCOMPANYING <br />STRUCTURAL CALCULATIONS REPORT FOR <br />ADDITIONAL INFORMATION. <br />5. PRIOR TO COMMENCEMENT OF WORK, THE <br />SOLAR INSTALLER SHALL VERIFY THE ROOF <br />FRAMING INFO BEFORE INSTALLATION AND <br />NOTIFY THE E.O.R. IF THERE IS ANY <br />INCONSISTENCY BETWEEN SITE <br />VERIFICATION AND FOLLOWING: 2x4 TRUSSES <br />@ 32" OC SPACING WITH MAX UNSUPPORTED <br />SPAN EQUAL OR LESS THAN 7 FT. <br />CSLB 1060243 C10CSLB1060243C10 <br />5216 W Crystal Ln <br />07/28/23