Laserfiche WebLink
MSPSLC UMCB <br />INV <br />~5 <br />8 <br />. <br />4 <br />5 <br />' <br />~99.48' <br />~100.54' <br />~2 <br />1 <br />. <br />1 <br />0 <br />' <br />~3 <br />9 <br />. <br />0 <br />9 <br />' <br />18'-9" <br />12 <br />' <br />- <br />5 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />21'-7" <br />JB <br />ACD <br />SITE PLAN WITH ROOF PLAN <br />SHEET NAME <br />SHEET NUMBER <br />PV-1 <br />PROJECT NAME <br />KI <br />M <br /> <br />Q <br />U <br />O <br />C <br /> <br />L <br />E <br />52 <br />1 <br />6 <br /> <br />W <br /> <br />C <br />R <br />Y <br />S <br />T <br />A <br />L <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />1 <br />0 <br />8 <br />5 <br />9 <br />1 <br />7 <br />8 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATEDESCRIPTION <br />VERSION <br />UR04/11/2023INITIAL RELEASE <br />DESIGN SUPPORT DAY OF INSTALL: <br />CHAT.POWUR.COM <br />07/20/2023REVISION A <br />09/08/2023REVISION B <br />SITE PLAN WITH <br />ROOF PLAN <br />1 SCALE: 3/32" = 1'-0" <br />NOTE: <br />A. ALL ELECTRICAL EQUIPMENT, INVERTERS/COMBINER, <br />DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL <br />NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’ <br />SUPPLY OR DEMAND PIPING. <br /> ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE <br />THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS <br />OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />NOTE: <br />3/4" OR GREATER EMT CONDUIT <br />RUN (7/8" ABOVE ROOF) <br />LEGEND <br />(E) POWER-ONE PVI-3.0-OUTD-S-US-A <br />INVERTER, (240V) <br />JUNCTION BOX <br />INV <br />JB <br />MSP MAIN SERVICE PANEL <br />GATE <br />FENCE <br />TREES <br />ENPHASE IQ COMBINER 4 <br />X2-IQ-AM1-240-4 (IEEE 1547:2018)CB <br />UTILITY METERUM <br />VENT, ATTIC FAN (ROOF OBSTRUCTION) <br />CHIMNEY <br />PROPERTY LINE <br />EXISTING <br />DRIVEWAY <br />W <br />C <br />R <br />Y <br />S <br />T <br />A <br />L <br /> <br />L <br />N <br />TWO - STORY <br />HOUSE <br />(E) 08 SUNPOWER SPR-X20-250-BLK <br />(250W) MODULES <br />(E) STRUCTURE <br />ROOF ACCESS POINT <br />ROOF ACCESS POINT <br />SLC SOLAR LOAD CENTER <br />A <br />A <br />ACD (E) AC DISCONNECT <br />B <br />6758&785$/127(67+(6( <br />3/$16$5(67$03(')25 <br />6758&785$/&2'(&203/,$1&( <br />2)7+(522))5$0,1* <br />6833257,1*7+(352326('39 <br />,167$//$7,2121/<7+(6( <br />3/$16$5(12767$03(')25 <br />:$7(5/($.$*(3902'8/(6 <br />5$&.,1*$1'$77$&+0(17 <br />&20321(1760867)2//2: <br />0$18)$&785(5*8,'(/,1(6$1' <br />5(48,5(0(1763/($6(6((7+( <br />$&&203$1<,1*6758&785$/ <br />&$/&8/$7,2165(3257)25 <br />$'',7,21$/,1)250$7,2135,25 <br />72&200(1&(0(172):25.7+( <br />62/$5,167$//(56+$//9(5,)< <br />7+(522))5$0,1*,1)2%()25( <br />,167$//$7,21$1'127,)<7+( <br />(25,)7+(5(,6$1< <br />,1&216,67(1&<%(7:((16,7( <br />9(5,),&$7,21$1')2//2:,1*[ <br />75866(6#2&63$&,1*:,7+ <br />0$;816833257('63$1(48$/ <br />25/(667+$1)7 <br />6WDPSHG 09/12/20236WDPSHG <br />6/30/2024 <br />5216 W Crystal Ln <br />9/22/2023