Laserfiche WebLink
1.CONTRACTOR SHALL COMPLY WITH <br />APPLICABLE LOCAL, STATE AND FEDERAL <br />CODES AND REGULATIONS PERTAINING TO <br />SAFETY OF PERSONS, PROPERTY AND <br />ENVIRONMENTAL PROTECTION. <br />2.EMERGENCY EXITS ARE REQUIRED IN ALL <br />SLEEPING AREAS AND MAY BE PROVIDED BY <br />A DOOR OR WINDOW OPENING DIRECTLY TO <br />THE OUTSIDE. EMERGENCY EGRESS <br />WINDOWS IN ALL SLEEPING ROOMS MUST <br />COMPLY WITH THE FOLLOWING: <br />A.A 20" MINIMUM OPENING WIDTH <br />B.A 24" MINIMUM OPENING HEIGHT <br />C.CLEAR OPENING NO HIGHER THAN 44" <br />ABOVE FINISHED FLOOR [CH 3 CRC] <br />3.LABELED SAFETY GLASS [CH 3 CRC] IS <br />REQUIRED IN: <br />A.TUB/SHOWER ENCLOSURE AND GLAZING <br />WITHIN 72" FROM THE BOTTOM OF <br />TUB/SHOWER <br />B.WINDOWS ADJACENT TO A DOOR <br />C.GLASS IN DOORS <br />D.GLAZING IN HAZARDOUS LOCATIONS <br />SHALL BE TEMPERED. . <br />E.ALL GLAZING WHERE THE NEAREST <br />EXPOSED EDGE OF THE GLASS IS <br />WITHIN 24'' OF EITHER VERTICAL EDGE <br />OF A DOOR IN THE PLANE OF THE DOOR <br />IN CLOSED POSITION. <br />F.GLAZING ON A WALL LESS THAN 180 <br />DEGREES FROM THE PLANE OF DOOR IN <br />A CLOSED POSITION AND WITHIN 24'' OFF <br />THE HINGE SIDE OF AN IN-SWINGING <br />DOOR. <br />4.ALL EXTERIOR DIMENSIONS ARE FROM FACE <br />OF SHEATHING, BLOCK OR STRUCTURE <br />(F.O.S.) TYP. UNLESS NOTED OTHERWISE. <br />VERIFY DIMENSION CHANGES WITH ENGINEER <br />PRIOR TO COMMENCEMENT OF WORK. <br />5.ALL INTERIOR DIMENSIONS ARE FROM FACE <br />OF GYPSUM BOARD. <br />6.CONTRACTOR SHALL NOT SCALE PLANS. ALL <br />DIMENSIONS SHALL BE VERIFIED IN FIELD. <br />7.ALL PLUMBING FIXTURES SHALL BE <br />COMPLYING WITH THE MAXIMUM FLOW RATES <br />AS NOTED IN THE RESIDENTIAL <br />CONSTRUCTION MINIMUM REQUIREMENTS. <br />8.PER SECTION 301.1.1 CALGREEN AND CIVIL <br />CODE 1101.3(C), ALL NON-COMPLIANT <br />PLUMBING FIXTURES WITHIN THIS RESIDENCE <br />SHALL BE REPLACED WITH <br />WATER-CONSERVING PLUMBING FIXTURES. <br />1 LAVATORY WITH BASE CABINET. FAUCET FLOW <br />SHALL NOT EXCEED 1.2 GALLONS AT 60 PSI, <br />MINIMUM 0.8 GALLONS PER MINUTE AT 20 PSI. <br />2 WATER CLOSET - 1.28 GALLONS PER FLUSH MAX. <br />3 SHOWER BASE: HOT-MAP PAN. PROVIDE TILE W/ <br />CEMENT BACKING MIN. 72" HIGHT ABOVE SHOWER <br />DRAIN, NET AREA 7.1 S.F. MIN., 30"DIA. CLEAR <br />SPACE MIN. (CPC 411.7). <br />4 SHOWER HEAD FLOW IS 1.8 GPM MAX. SHOWER <br />FITTING TO HAVE ACCESS PANEL OR ONE PIECE <br />WELD TRAP PER LOCAL CODE <br />5 TEMPERED GLASS SHOWER ENCLOSURE, FRAMED <br />GLASS WITH 22" OPENING MIN. UNOBSTRUCTED <br />FOR EGRESS. <br />REFER TO SHEET A12.00 FOR WALL TYPE DETAILS, U.N.O. <br />EXISTING 2x WALL TO REMAIN <br />NEW 2x WALL <br />AREA NOT IN CONTRACT <br /> DOOR & WINDOW SCHEDULE <br />3'-5" <br />1 <br />A9.00 <br />W/H <br />12 <br />' <br />- <br />0 <br />" <br />22'-0" <br />5'-0" <br />8' <br />- <br />0 <br />" <br />3' <br />- <br />3 <br />" <br />6' <br />- <br />0 <br />" <br />5' <br />- <br />6 <br /> <br />1 <br />/ <br />2 <br />" <br />5' <br />- <br />6 <br /> <br />1 <br />/ <br />2 <br />" <br />12 <br />' <br />- <br />0 <br />" <br />2' <br />- <br />8 <br />" <br />2' <br />- <br />6 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />D0 <br />1 <br />. <br />0 <br />1 <br />D01.02 <br />D01.03 <br /> W01.01 W01.02 <br />1 <br />A08.00 <br />2 <br />A08.00 <br />3 <br />A08.00 <br />4 <br />A08.00 <br />1 <br />2 <br />3 <br />4 <br />5 <br /> <br /> <br />W <br />0 <br />1 <br />. <br />0 <br />3 <br /> EW01.01 EW01.02 <br /> W01.04* <br /> EW01.03 <br /> <br /> <br />W <br />0 <br />1 <br />. <br />0 <br />4 <br /> <br /> <br />E <br />W <br />0 <br />1 <br />. <br />0 <br />5 <br /> EW01.06 <br />6 EXISTING WATER HEATER LOCATION TO REMAIN. <br />7 EXISTING WASHER / DRYER LOCATION TO REMAIN. <br />6 <br />7 <br />8 LEGALIZE WINDOW REPLACEMENT WITH NEW AT <br />EXISTING LOCATION. <br />8 <br />D01.04 <br />9 NEW COVERED PATIO OVER EXISTING CONCRETE SLAB. <br />9 <br />20'-0" <br />10 LEGALIZE INSTALLATION OF CENTRAL AIR FOR MAIN HOUSE. <br />10 <br /> <br /> <br />E <br />W <br />0 <br />1 <br />. <br />0 <br />7 <br />8 <br />5'-3"2'-6" <br />3'-1" <br />Ø2'-6" <br />2 <br />A9.00 <br />8 <br />EQ.EQ. <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />& <br /> N <br />E <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />51 <br />2 <br />1 <br /> <br />W <br />. <br /> <br />R <br />o <br />b <br />e <br />r <br />t <br />s <br /> <br />D <br />r <br />. <br /> <br />& <br /> <br /># <br />2 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />11 <br />8 <br />8 <br />1 <br /> <br />o <br />s <br />t <br />o <br /> <br />r <br />o <br />a <br /> <br />a <br />r <br />e <br />n <br /> <br />r <br />o <br />e <br /> <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />8 <br />4 <br />0 <br /> <br /> <br /> <br /> <br /> <br />T <br />: <br /> <br />7 <br />1 <br />4 <br />. <br />6 <br />5 <br />1 <br />. <br />9 <br />9 <br />4 <br />5 <br /> <br /> <br /> <br />E <br />: <br /> <br />e <br />s <br />n <br />2 <br />b <br />a <br />o <br />o <br />. <br />o <br />06/27/2024 <br />2 <br />FLOOD ZONE - 5121 W <br />Roberts Dr & #23/19/2025