1 ELECTRIC PLAN <br />1/4"=1'-0" <br />1.2 <br />GFCI <br />WP <br />+48'' GFCI <br />AFCI <br />AFCI <br />CTV AFCI <br />AFCI <br />W/H <br />AFCI <br />1.1 <br />1.CONTRACTOR SHALL COMPLY WITH APPLICABLE LOCAL, <br />STATE AND FEDERAL CODES AND REGULATIONS PERTAINING <br />TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL <br />PROTECTION. <br />2.ALL ELECTRICAL OUTLET TO BE MOUNTED @ 15" A.F.F. <br />3.PROVIDE TAMPER-RESISTANT FOR ALL 15 & 20 AMP <br />RECEPTACLES IN NEW CONSTRUCTION AREA PER CEC 406.12. <br />2.1 <br />FLUSH WALL MOUNTED PHONE RECEPTACLE <br />CTV FLUSH WALL MOUNTED CABLE TV RECEPTACLE <br />FLUSH WALL MOUNTED DUPLEX RECEPTACLE, <br />TAMPER RESISTANT <br />FLUSH WALL MOUNTED DEDICATED DUPLEX <br />RECEPTACLE <br />FLUSH WALL MOUNTED HALF-SWITCHED DUPLEX <br />RECEPTACLE <br />FLUSH WALL MOUNTED QUADRAPLEX RECEPTACLE <br />GROUND FAULT CIRCUIT INTERRUPTERGFCI <br />WATERPROOF RECEPTACLEWP <br />EXISTING 200AMP ELECTRICAL PANEL FOR MAIN <br />HOUSE.2.2 <br />OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER <br />RESISTANT PER SECTION 406.9(B) (1). <br />1.1 <br />PROVIDE A MINIMUM OF (1) 20-AMP CIRCUIT FOR <br />BATHROOM OUTLET. SUCH CIRCUIT SHALL HAVE NO <br />OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN <br />ONE BATHROOM, PER CEC 210-52(C) (1). <br />1.2 <br />CEILING MOUNTED SMOKE DETECTOR IN EACH <br />BEDROOM & KITCHEN. INSTALL +30" FROM AIR INTAKE <br />SMOKE DETECTOR SYSTEM SHALL DIRECT WIRED, <br />INTERCONNECTED, SHALL BE EQUIPPED WITH A <br />BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN <br />THE BATTERY IS LOW. <br />A.AMINIMUM OF 20 FT. FROM PERMENANT <br />COOKING EQUIPMENT (OR 10 FT WITH PHOTO <br />ELECTRIC TYPE.) <br />B.A MINIMUM OF 3 FT. FROM BATHROOM. <br />CEILING MOUNTED CARBON MONOXIDE ALARM <br />ALARM TO BE INTERCONNECTED, SHALL BE <br />EQUIPPED WITH A BATTERY BACKUP <br />RECESSED LED DOWN LIGHT FIXTURE <br />WALL MOUNTED EXTERIOR LED LIGHT FIXTURE, HIGH <br />EFFICACY AND CONTROL BY MOTION SENSOR AND <br />PHOTO-SENSOR COMBINATIONS. <br />D / VS <br />LIGHT SWITCH. ALL SWITCHES TO HAVE DIMMER <br />CONTROL, EXCEPT, UTILITY & LAUNDRY RM, GARAGE <br />WALL MOUNTED BATHROOM LED LIGHT FIXTURE <br />EF <br />SD <br />CM <br />D INDICATE DIMMER <br />VS INDICATE OCCUPANCY SENSOR <br />#FINISHED CEILING HEIGHT <br />CEILING MOUNTED EXHAUST FAN/FLUORESCENT LIGHT <br />COMBINATION. EXHAUST FAN TO EXTERIOR WITH RATE <br />= 50 CFM. EXHAUST FAN MUST BE CONTROLLED BY A <br />HUMIDISTAT WHICH SHALL BE CAPABLE ADJUSTMENT <br />BETWEEN RELATIVE HUMINITY RANGE OF 50% TO 80%. <br />EXISTING SMOKE ALARMS & EXISTING CARBON <br />MONOXIDE ALARM IN EXISTING HALLWAY. <br />2.3 EXHAUST FAN MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. AND SHOULD BE HUMIDISTAT FAN. <br />PROVIDE LIGHTING WITH CONTROLLED BY VACANCY <br />SENSOR IN BATHROOM, W.I. CLOSET. <br />4.ALL INSTALLED LUMINARIES MUST BE HIGH EFFICACY IN <br />ACCORDANCE WITH TABLE 150.0-A. <br />5.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. <br />6.IN BATHROOMS, GARAGE, LAUNDRY ROOM, UTILITY ROOM, AT <br />LEAST ONE LUMINARIES IN EACH OF THESE SPACES MUST BE <br />CONTROLLED BY VACANCY SENSOR. <br />7.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING <br />MUST MEET THE REQUIREMENT IN ITEM 150.0(k)3Ai (ON AND <br />OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM <br />150.0(k)3Aii (PHOTOCELL AND MOTION SENSOR) OR ITEM <br />150.0(k)3Aiii (PHOTO CONTROL AND AUTOMATIC TIME SWITCH <br />CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS). <br />8.SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: <br />[150.0(K) / 160.5(A)] <br />A.KITCHENS. ALL INSTALLED WATTAGE OF LUMINARIES IN <br />KITCHENS SHALL BE HIGH EFFICACY. <br />B.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, <br />WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES <br />SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY <br />AN OCCUPANCY OR VACANCY SENSOR. <br />C.HABITABLE SPACES. ALL LUMINAIRES SHALL BE HIGH <br />EFFICACY AND SHALL BE CONTROLLED BY A VACANCY/ <br />OCCUPANCY SENSOR OR DIMMER. <br />D.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE <br />BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT <br />SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE <br />CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR <br />COMBINATION (WITH OVERRIDE). SEE 150(K)3 FOR <br />REQUIREMENTS. <br />2.4 <br />2.6 <br />PROVIDE NEW ACCESS DOOR FOR ADDITION ATTIC AREA. <br />OPENING SHALL BE 30" x 30" WITH 30" MIN. HEADROOM. <br />EXISTING ACCESS DOOR FOR EXISTING ATTIC AREA. <br />OPENING IS 30" x 30" WITH 30" MIN. HEADROOM. ACCESS <br />DOOR IS WITHIN 20 FEET OF FURNACE UNIT AND HAVE A <br />CONTINUOUS SOLID PATHWAY 24" MIN. WIDE WITH A <br />SWITCH CONTROLLED LIGHT. <br />2.5 <br />NEW SMOKE ALARMS WITHIN 20 FEET OF COOK TOP <br />SHALL BE IONIZED OR PHOTOELECTRIC TYPE. <br />SD <br />EF <br />CM <br />SD <br />vs <br />W/H <br />D <br />2' <br />- <br />0 <br />" <br />7' <br />- <br />1 <br />" <br />2' <br />- <br />6 <br />" <br />3'-0"6'-5" <br />SD <br />SDSD <br />CM SD <br />(E)(E) <br />(E)(E) <br />(E) <br />2.1 <br />2 CEILING / LIGHTING PLAN <br />1/4"=1'-0" <br />2.22.3 <br />2.5 <br />2.4 <br />2.1 <br />2.1 <br />2.1 <br />2.6 <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />& <br /> N <br />E <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />51 <br />2 <br />1 <br /> <br />W <br />. <br /> <br />R <br />o <br />b <br />e <br />r <br />t <br />s <br /> <br />D <br />r <br />. <br /> <br />& <br /> <br /># <br />2 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />11 <br />8 <br />8 <br />1 <br /> <br />o <br />s <br />t <br />o <br />k <br /> <br />r <br />o <br />a <br /> <br />a <br />r <br />e <br />n <br /> <br />r <br />o <br />v <br />e <br /> <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />8 <br />4 <br />0 <br /> <br /> <br /> <br /> <br /> <br />T <br />: <br /> <br />7 <br />1 <br />4 <br />. <br />6 <br />5 <br />1 <br />. <br />9 <br />9 <br />4 <br />5 <br /> <br /> <br /> <br />E <br />: <br /> <br />e <br />s <br />i <br />n <br />2 <br />b <br />i <br />@ <br />a <br />o <br />o <br />. <br />o <br />06/27/2024 <br />FLOOD ZONE - 5121 W <br />Roberts Dr & #23/19/2025