My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 5121 W Roberts Dr & #2 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Roberts Dr
>
5121 W Roberts Dr
>
FLOOD ZONE - 5121 W Roberts Dr & #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2025 9:08:13 AM
Creation date
6/9/2025 9:07:50 AM
Metadata
Fields
Template:
Plan
Permit Number
101119306
101119307
Full Address
5121 W Roberts Dr
5121 W Roberts Dr Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Dong Engineering Inc. <br />ADDITION + ADU <br />5121 W.ROBERTS DR #2, SANTA ANA, CA 92704 <br />Job#: 240056 <br />Date: 11/27/2024 <br />PLAN: 2 <br />CODE: CBC 2022 <br />A. General: <br />Number of stories 1 <br />Building risk category II <br />Design Code CBC 2022 <br />Load standard ASCE 7-16 ASCE 7-16 <br />Design Load Combination ASD <br />B. Lateral Loads Data: <br />WIND STANDARD ASCE 7-16(Directional Procedure) <br />Wind Exposure C <br />Wind Speed 110 <br />Enclosure Enclosed Building <br />Velocity pressure qz = 0.00256KzKztKdKeV2 (26.10-1) <br />Velocity pressure exposure coefficient Kz (Table 26.10-1) <br />Directionality Factor Kd (Table 26.6-1) <br />Topographic factor defined Kzt (26.8.2) <br />Gust Effect Factor G (26.11.1) <br />Pressures for MWFRS p = qGCp – qi(GCpi)(27.3-1) <br />External pressure coefficient Cp (Fig. 27.3-1) <br />Internal pressure coefficient Gcpi (Table 26.13-1) <br />SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure) <br />Seismic Design Category (Table 11.6-1) <br />Importance factor I (Table 1.5-2) <br />Soil Site Class D-Default (Table 20-3-1) <br />Response modification coefficient R = 6.5 (Table 12.2-1) <br />System overstrength coefficient Ω = 2.5 (Table 12.2-1) <br />Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2) <br />Building Height (ft)13 <br />Building period T=Ta (sec) = 0.25 (Formula 12.8-7) <br />Base Shear Adjustment Factor = 1 <br />Seismic response coefficient Cs = 0.16 (Formula 12.8-2) <br />BUILDING INFORMATION <br />28 of 44 <br />FLOOD ZONE - 5121 W <br />Roberts Dr & #23/19/2025
The URL can be used to link to this page
Your browser does not support the video tag.