My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1329 W McFadden Ave, Unit 2 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
1329 W McFadden Ave Unit# 2
>
1329 W McFadden Ave, Unit 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2025 9:12:54 AM
Creation date
6/9/2025 9:12:48 AM
Metadata
Fields
Template:
Plan
Permit Number
101121764
Full Address
1329 W McFadden Ave Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2022 Single-Family Residential Mandatory Requirements Summary <br />5/6/22 <br /> <br />§ 150.0(m)13: <br />Space Conditioning System Airflow Rate and Fan Efficacy. <br />a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must <br />be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air <br />handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal <br />cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with <br />Reference Residential Appendix RA3.3. * <br /> <br /> <br />Ventilation and Indoor Air Quality: <br />§ 150.0(o)1: Requirements for Ventilation and Indoor Air Quality <br />Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * <br />§ 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. <br />dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that <br />prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI <br />ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for <br /> <br />§ 150.0(o)1C: <br />Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . <br />and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial <br />spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. <br />Local Mechanical Exhaust. <br />controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or <br />continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per <br />Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. <br />be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference <br />Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the <br />§ 150.0(o)2: Field Verification and Diagnostic Testing. <br />and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods <br />must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow <br /> <br />Pool and Spa Systems and Equipment: <br /> <br />§ 110.4(a): <br />Certification by Manufacturers. with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not <br />§ 110.4(b)1: Piping. <br />Covers. <br />§ 110.4(b)3: Directional Inlets and Time Switches for Pools. <br />Pilot Light. <br />§ 150.0(p): Pool Systems and Equipment Installation. * <br />Lighting: <br /> <br />§ 110.9: <br />Lighting Controls and Components. <br /> * <br />§ 150.0(k)1A: Luminaire Efficacy. <br />range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen <br />Screw based luminaires. <br />§ 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. <br />§ 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. <br />§ 150.0(k)1E: Blank Electrical Boxes. luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor <br />§ 150.0(k)1F: Lighting Integral to Exhaust Fans. * <br />Page 3 of 5 <br />1329 W McFadden Ave, <br />Unit 24/24/2025
The URL can be used to link to this page
Your browser does not support the video tag.