Laserfiche WebLink
PARTITION LEGENDKEYNOTESTACTILE "EXIT STAIR DOWN" SIGNAGE. SEE DETAIL #2TACTILE STAIR LEVEL IDENTIFICATION SIGNAGE. SEE DETAIL #3#1. A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" SHALL IDENTIFY EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN.EXITROUTECORRESPONDINGGRADE II BRAILLELINE OF FINISHED FLOOR48" MIN.60" MAX.#2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE "EXIT STAIR DOWN"EXITSTAIRDOWNCORRESPONDINGGRADE II BRAILLELINE OF FINISHED FLOOR48" MIN.60" MAX.#3. A TACTILE SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: "LEVEL #" **AT EXIT DISCHARGE, SIGN SHALL HAVE RAISED FIVE-POINTED STAR TO LEFT OF IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF STAIR SHALL BE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. PROVIDE ROOF ACCESS/NO ROOF ACCESS AS REQUIRED.STAIR 01LEVEL1CORRESPONDINGGRADE II BRAILLE1" HIGHLINE OF FINISHED FLOOR60" MAX.1 1/2" TEXT5" TEXT12" MIN.18" MIN.EXISTING PARTITIONEXISTING DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION SHOWN.NEW PARTITIONAREA NOT IN CONTRACT (N.I.C.)COMMON PATH OF TRAVELEGRESS PATH OF TRAVELCEILING MOUNTED EXIT SIGN. DARK QUADRANT INDICATES FACE. ARROW(S) INDICATE DIRECTION. LITHONIA LRP-GMR, EDGE LIT, TOP MOUNTED WITH SILVER INSERTS.ACCESSIBLE COMMON PATH OF TRAVEL123TACTILE "EXIT ROUTE" SIGNAGE. SEE DETAIL #1SFECBUILDING STANDARD SEMI-RECESSED FIRE EXTINGUISHER CABINETTACTILE EXIT SIGNSTACTILE EXIT SIGNPERMANENT SIGNAGE TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR AT +48" A.F.F. MIN MEASURED TO THE BASELINE LOWEST LINE OF BRAILLE AND 60" A.F.F. MAX MEASURED TO THE BASELINE OF THE HIGHEST LINE OF THE RAISED CHARACTERS. MOUNTED LOCATION MUST ALLOW A PERSON TO APPROACH WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN SWING PATH OF THE DOOR [11B-307 (PROTRUDING OBJECTS); SEC. 1013.4 AND 11B-703 (TACTILE EXIT SIGNAGE)]LETTERS & NUMBERS SHALL BE RAISED 1/32", UPPER CASE, SANS SELF TYPE AND SHALL BE ACCOMPANIED WITH GRADE II BRAILLE RAISED CHARACTERS. SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN 2" CHARACTERS AND BRAILLE SHALL BE IN HORIZONTAL FORMAT AND WITH BRAILLE PLACED 3/8" MIN AND 1/2" MAX DIRECTLY BELOW THE TACTILE CHARACTERS; FLUSH LEFT OR CENTERED.EXITEQ EQ60" MAX.CORRESPONDING GRADE II BRAILLE48" MIN..NOTES1. SIGNS W/ RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE & 60" MAXIMUM ABOVE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. MOUNTING LOCATION SHALL BE BEYOND THE ARC OF THE DOOR SWING BETWEEN THE CLOSED POSITION AND THE 45 DEGREE OPEN POSITION. 2. RAISED CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MINIMUM AND 110% MAXIMUM OF THE HEIGHT OF THE UPPERCASE "T". STROKE THICKNESS OF THE UPPERCASE "T" SHALL BE 15% MAXIMUM OF THE HEIGHT OF THE CHARACTER. CHARACTERS SHALL BE UPPER CASE & SANS SERIF OR SIMPLE SERIF. LITERARY BRAILLE STANDARD DIMENSIONSDOT DIAMETER - .059" HORIZONTAL SEPARATION BETWEEN CELLS -.241"INTER-DOT SPACING - .090" VERTICAL SEPARATION BETWEEN CELLS -.395"12"60"NOTE: ALL SIGNAGE SHALL COMPLY WITH 2022 CBC 11B-703.INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) PER CBC 11B-703.7.2.1SUITE 880SUITE 860SUITE 850SUITE 840SUITE 820SUITE 800EXIT #1EXIT #22323A-0.7115'-8" LF TO EXIT #2 155'-2" LF TO EXIT #166'-4"41' - 4"102'-2" LF TO EXIT #269'-4" LF TO EXIT #160'-10" 60'-11" LF TO EXIT #2111'-2" LF TO EXIT #171'-8"RECEPTION /WAITINGBREAK AREACOPYSTORAGECONFERENCEROOMBREAK AREASFEC1111111111SERVER RM.122' - 7"SCALE:NTSSYMBOL OF ACCESSIBILITY SIGNAGE5OCCUPANT CALCULATIONEXIT CALCS SPRINKLERED BUILDINGMAXIMUM TOTAL # OF OCCUPANTSTOTAL OCCUPANT SQUARE FOOTAGE# OF EXITS REQUIRED FOR TABLE 1006.3.3# OF EXITS FOR SUITE28±6,91011REQUIRED EXIT WIDTH (INCHES)REQUIRED STAIR WIDTH (INCHES)72" PROVIDED84" PROVIDED0.2 X 96 = 19.2"REQUIRED0.3 X 96 = 28.8"REQUIREDDATE:DRAWN:REVIEWED:PROJECT NO:SCALE:OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVEDSHEET TITLE:SHEET NO:SEAL AND STAMP:CONSULTANTS:PROJECT:CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO -NEW JERSEY - NEW YORK6083 Bristol ParkwayCulver City, CA 9023018600 MacArthur Blvd., Suite 100 Irvine, CA 92612515 South Flower Street, Suite 1200Los Angeles, CA 90071T 310.553.3252T 949.724.8958T 213.929.1400DRAWINGS ISSUE485C US Route 1 South, Suite 105Iselin, NJ 08830T 848.200.1200711 3rd Ave., 6th FloorNew York, NY 10017T 917.512.6688www.saaia.comT 415.390.6793NOT FOR CONSTRUCTIONIF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USINGRECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENTACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.575 Market Street, #502San Francisco, CA 94105As indicatedA-0.5C04/10/24AWJN/MP634495EXIT ROUTES AND TACTILESIGNAGESUITE 850 & 860DEMISING WALL6 E HUTTON CENTREDRIVESANTA ANA, CA 92707*NOTE: PER CBC 303.1.2 SMALL ASSEMBLY SPACESTHE FOLLOWING ROOMS AND SPACES SHALL NOT BE CLASSIFIED AS ASSEMBLY OCCUPANCIES:1. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS AND ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY.2. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES THAT IS LESS THAN 750 SQUARE FEET (70M²) IN AREA AND ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY.DATE DESCRIPTION DELTA05/17/24 ISSUE FOR PLANNING05/20/24 ISSUE FOR PLAN CHECKNSCALE:1/8" = 1'-0"EXIT ANALYSIS / COMMON PATH OF EGRESS DISTANCE / MAXIMUM TRAVEL DISTANCE / TACTILE EXIT SIGN LOCATIONS1EXIT ANALYSIS - SUITE 850USE SQUARE FOOTAGE LOAD FACTOR OCCUPANTS LOADRECEPTION/WAITING 196 15 13BREAK AREAOFFICE SPACE152 15 102,866 150 19COPYSTORAGE147 150 1122 300 1OCCUPANT CALCULATIONMAXIMUM TOTAL # OF OCCUPANTSTOTAL OCCUPANT SQUARE FOOTAGE# OF EXITS REQUIRED FOR TABLE 1006.3.3# OF EXITS FOR SUITE68±4,17523CONFERENCE ROOM 355 15 24EXIT ANALYSIS - SUITE 860USE SQUARE FOOTAGE LOAD FACTOR OCCUPANTS LOADOFFICE SPACE 1,841 150 13BREAK AREASERVER ROOM209 15 1425 300 1NELSONALGAZENo. C-21090REN. 03/31/2025L,CENSE' ARC+,7EC7S7A7E O) CAL,)ORN,A6 E Hutton Center Dr # 850 &860 - 101119469-707/24/2024