1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" )15" MIN..48" MAX.10" MAX.UNOBSTRUCTED SIDE REACH15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH(A)(C)(B)(D)48" MIN.48" MIN.48" MIN.48" MIN.27" MAX.X<80"GUARDRAIL OR BARRIERNOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAILIN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A HAZARD, THEEXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROMTHE DIRECTION OF THE STAIR FLIGHT.11B-505.511B-505.611B-504.4.111B-505.2CONTRASTING COLOR STRIPE SHALL BE 2"-4" WIDE, POSITIONED PARALLEL TO ANDNOT MORE THAN 1" AWAY FROM THE NOSE. THE STRIPE SHALL EXTEND THE FULLWIDTH OF THE STEP AND SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIPRESISTANT AS THE REST OF THE TREADS. PAINTED STRIPES ARE ACCEPTABLE.GROOVES ARE NOT ACCEPTABLE.WHERE REQUIRED:1.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND THE LOWERTREAD MARKED BY A COLOR STRIPE PROVIDING CLEAR VISUAL CONTRAST.2.EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADSMARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST.PROVIDE CONTINUOUSHANDRAILS ON BOTHSIDES OF THE STAIRSFOR THE FULL LENGTHOF EACH STAIR FLIGHTHANDRAIL EXTENSIONS MUST BE PROVIDEDAT THE TOP AND BOTTOM OF EACH STAIR FLIGHT AND MUSTRETURN TO A WALL, GUARD, OR THE LANDING SURFACE OR SHALLBE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHTNOTE: INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRSSHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS1 1/2"MIN.1 1/2"MIN.1" MAX.2"-4"CONTRASTING COLOR STRIP11B-504.4.111B-505.1011B-505.10(B) SECTION/ELEVATION(B-ALT) ALT. SECTION/ELEVATION34" - 38"PLUS (1) TREAD DEPTH MIN12".12"MIN.11" MIN. UNIFORMTREAD DEPTH4"-7" UNIFORMRISER HEIGHTX<27"12"MINNOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROM THE DIRECTION OF THE STAIR FLIGHT.11B-505.1011B-505.1011B-505.1011B-505.7.14"-6 1/4" PERIMETER4"-6 1/4" PERIMETER(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE)2 1/4"2 1/4"11B-505.7.2*EXCEPTIONS1. THE CLEAR WIDTH SHALL BE PERMITTED TO BEREDUCED TO 32" MIN. FOR A LENGTH OF 24" MAX.PROVIDED THAT REDUCED WIDTH SEGMENTS ARESEPARATED BY SEGMENTS THAT ARE 48" LONG MIN.AND 36" WIDE MIN.2. THE CLEAR WIDTH FOR WALKING SURFACES INCORRIDORS SERVING AN OCCUPANT LOAD OF 10 ORMORE SHALL BE 44" MIN.3. THE CLEAR WIDTH FOR SIDEWALKS AND WALKSSHALL BE 48" MIN.. WHEN, BECAUSE OFRIGHT-OF-WAY RESTRICTIONS, NATURAL BARRIERSOR OTHER EXISTING CONDITIONS, THE ENFORCINGAGENCY DETERMINES THAT COMPLIANCE WITH THE48" CLEAR SIDEWALK WIDTH WOULD CREATE ANUNREASONABLE HARDSHIP, THE CLEAR WIDTH MAYBE REDUCED TO 36".4. THE CLEAR WIDTH FOR AISLES SHALL BE 36" MIN. IFSERVING ELEMENTS ON ONLY ONE SIDE, AND 44"MIN. IF SERVING ELEMENTS ON BOTH SIDES.5. THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TOACCESSIBLE TOILET COMPARTMENTS SHALL BE 44"EXCEPT FOR DOOR-OPENING WIDTHS AND DOORSWINGS.(B) EXCEPTION 1(A) MINIMUM CLEAR WIDTH, MAX. SLOPE2.0% MAX.5.0% MAX.(TYP U.O.N.)36" MIN.*36" MIN.*32" MIN.24" MAX.48" MIN. 24" MAX.11B-403.5.1(A) FORWARD APPROACH48" MIN.30 MIN.30" MIN.48" MIN.(B) PARALLEL APPROACH(1) THE CLEAR FLOOR SPACE (CFS) MUST BE STABLE,FIRM, AND SLIP RESISTANT.(2) OPENINGS MUST NOT ALLOW THE PASSAGE OF ASPHERE MORE THAN 1/2" IN DIAMETER. ELONGATEDOPENINGS MUST BE PERPENDICULAR TO THEDOMINANT DIRECTION OF TRAVEL.CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THECLEAR FLOOR SPACE. SLOPES WITHIN THE CFS MUST BE NO GREATER THAN 2% THE CFS MAY INCLUDE COMPLIANT KNEE AND TOE CLEARANCE. ONE FULLY UNOBSTRUCTED SIDE OF THE CFS MUST ADJOIN AN ACCESSIBLE ROUTE OR ANOTHER CLEAR FLOOR OR GROUND SPACE11B-305.5 11B-305.511B-302.111B-302.311B-305.211B-305.411B-305.69" MIN.8" MIN.27" MIN.11" MIN.25" MAX.30" MIN.(A) KNEE CLEARANCE ELEVATION(B) KNEE CLEARANCE PLAN17"-25"30" MIN.9"6" MAX.(A)ELEVATION(B)PLAN11B-306.3 11B-306.311B-306.2 11B-306.2>10"-24" MAX.34" MAX.46" MAX.34" MAX.48" MAX.10" MAX.(a) (b)48" MAX.20" MAX.>20"-25" MAX44" MAX.(a) (b)OBSTRUCTED HIGH FORWARD REACHOBSTRUCTED HIGH SIDE REACH11B-308.2.111B-308.3.111B-308.2.211B-308.3.2X≥80"4" MAX.X>27"12" MAX.27" - 80"12" MAX.27" MAXX>12"X>12"80" MIN.LIMITS OF PROTRUDING OBJECTS(A)(B)POST-MOUNTED PROTRUDING OBJECTS11B-307.211B-307.3(A) FRONT APPROACH, PULL SIDE(B) FRONT APPROACH, PUSH SIDE(C) HINGE APPROACH, PULL SIDE(D) HINGE APPROACH, PUSH SIDE(E) LATCH APPROACH, PULL SIDE(F) LATCH APPROACH, PUSH SIDE18"MIN.60" MIN.48" MIN.ADD 12" IF A CLOSER ANDLATCH ARE PROVIDEDADD 6" AT EXTERIOR SIDEOF EXTERIOR DOORS60" MIN.36" MIN.42" MIN.22" MIN.48" MIN.24" MIN.42" MIN.24" MIN.ADD 4" IF CLOSER AND LATCH IS PROVIDED11B-404.2.4.111B-404.2.4.111B-404.2.4.111B-404.2.4.111B-404.2.4.111B-404.2.4.1ADD 4" IF CLOSER AND LATCH IS PROVIDED(A) RECESSED DOOR, PULL SIDE(B) RECESSED DOOR PUSH SIDE18"MIN.48" MIN.ADD 12" IF ACLOSER ANDLATCH AREPROVIDEDADD 6" ATEXTERIOR SIDEOF EXTERIORDOORS60" MIN.X>8"X>8"3'-0"11B-404.2.4.111B-404.2.4.111B-404.2.6 11B-404.2.611B-404.2.611B-307.42.0% MAX2.0% MAX.RAMP DOWN 8.33% MAX.2.0% MAX2.0% MAX.2.0% MAX.2.0% MAX.8.3% MAX.2.0% MAX.8.3% MAX.2.0% MAX.2.0% MAX.2.0% MAX.2.0% MAX.2.0% MAX.8.3% MAX.2.0% MAX.2.0% MAX.2.0% MAX.PROVIDE CONTINUOUS HANDRAILSON BOTH SIDES OF RAMP FOR THEFULL LENGTH OF EACH RAMP RUN1 1/2"MIN.1 1/2"MIN.TOP LANDING WITH A CHANGEIN DIRECTION SHOWNPROVIDE EDGE PROTECTION ATEACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMPLANDINGS WHERE A CHANGE IN LEVEL OCCURS.EXCEPTIONS:1. WHERE RAMPS ARE NOT REQUIRED TO HAVEHANDRAILS AND AT CURB RAMP FLAIRS NOT STEEPER THAN 1:10 HAVE FLARED SIDES.2.ON THE SIDES OF RAMP LANDINGS SERVING ANADJOINING RAMP RUN OR STAIR.3.WHERE AN ABRUPT CHANGE IN LEVEL OF 1/2"MAX. OCCURS WITHIN 10" OF THE MINIMUMLANDING AREA.2" - 4" HIGH EDGE PROTECTION (CURB OR BARRIER) SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF A RAMP TO PREVENT WHEEL ENTRAPMENT.HANDRAIL EXTENSIONS MUST BE PROVIDED AT THE TOP AND BOTTOMLANDINGS OF EACH RAMP RUN AND MUSTRETURN TO A WALL, GUARD, OR THE LANDINGSURFACE OR SHALL BE CONTINUOUS TO THEHANDRAIL OF AN ADJACENT RAMP RUN.NOTE: INSIDE HANDRAILS ON SWITCHBACK ORDOGLEG RAMPS SHALL BE CONTINUOUSBETWEEN FLIGHTS OR RUNSHANDRAILS MAY PROJECT INTO THEREQUIRED CLEAR WIDTH OF THERAMP AT EACH SIDE A MAXIMUM OF3 1/2" AT THE HANDRAIL HEIGHTAT LEAST AS WIDE AS THEWIDEST RAMP RUN (TYP.)60" MIN.BOTTOM LANDING5'-0" MINIMUMINTERMEDIATE LANDING(STRAIGHT)5'-0" MINIMUMINTERMEDIATE LANDING(CHANGE IN DIRECTION)60" MINIMUMINTERMEDIATE LANDING(CHANGE IN DIRECTION)5'-0" MINIMUMTOP LANDINGRAMP RUNDOWNRAMP RUNDOWNRAMP RUNDOWN5'-0" MINIMUMTOP LANDINGNOTES:·THE CLEAR WIDTH OF A RAMP RUN MUST BE 48" MINIMUM.·WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES ARE PERMITTEDTO OVERLAP THE REQUIRED LANDING AREA. DOORS, IN ANY POSITION, MUST NOT REDUCE THE MINIMUMDIMENSION OF THE RAMP LANDING TO LESS THAN 42"·LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER.BOTTOM LANDING11B-40511B-40511B-505.10.111B-505.10.111B-1012.4X>27"12"MIN.34" - 38"12"MIN.12"MIN.30" MAX. RISE FOREACH RAMP RUN(B) HANDRAIL MOUNTING HEIGHT AND EXTENSIONS1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" )4"-6 1/4" PERIMETER4"-6 1/4" PERIMETER(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE)2 1/4"2 1/4"CURB 2" MIN. - 4" MAX. TO PREVENT THE PASSAGE OF A 4" DIAMETER SPHEREGUIDE RAIL POSITIONED TO PREVENTTHE PASSAGE OF A 4" DIAMETER SPHERE(D) EDGE PROTECTION - BARRIER(D) EDGE PROTECTION - CURB43" MAX> 66"34" - 44"404.2.11 VISION LIGHTSDOORS, GATES, AND SIDE LIGHTS ADJACENT TO DOORS OR GATES, CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE GLAZED PANEL LOCATED 43 INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR.EXCEPTION: VISION LIGHTS WITH THE LOWEST PART MORE THAN 66 INCHES (1675 MM) FROM THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.11.404.2.10 DOOR AND GATE SURFACESSWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH (1.6 MM) OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED.EXCEPTIONS:1. SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.10.2. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH (255 MM) BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT.3. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLYWITH 404.2.10.4. EXISTING DOORS AND GATES WITHOUT SMOOTH SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO PROVIDE SMOOTH SURFACES COMPLYING WITH 404.2.10 PROVIDED THAT IF ADDED KICK PLATES ARE INSTALLED, CAVITIES CREATED BY SUCH KICK PLATES ARE CAPPED.FINISH FLOOR OR GROUND7" - 8"30" - 44"5" MAX.35" MIN.2" MIN.VERTICAL ACTUATION BARWHERE PUSH PLATES ARE PROVIDED THERE SHALL BE TWO PUSH PLATESPUSH PLATE 4" SQUARE OR 4 " DIAMETER MINIMUMINT'L SYMBOL OF ACCESSIBILITY, TYPICAL.SCALE:3/8" = 1'-0"STAIRWAYS 13SCALE:1/4" = 1'-0"ACCESSIBLE ROUTE MIN. WIDTH1SCALE:1/4" = 1'-0"REQUIRED CLEAR FLOOR SPACE5SCALE:3/8" = 1'-0"KNEE & TOE CLEARANCE6SCALE:1/4" = 1'-0"OBSTRUCTED REACH3SCALE:3/8" = 1'-0"PROTRUDING OBJECTS7SCALE:1/4" = 1'-0"DOOR MANUEVERABILITY9SCALE:1/4" = 1'-0"RECESSED DOOR & GATES MANEUVERING10SCALE:1/4" = 1'-0"DOORS & GATES IN SERIES 11SCALE:3/8" = 1'-0"REDUCED VERTICAL CLEARANCE 12SCALE:1/4" = 1'-0"RAMPS 16SCALE:1/2" = 1'-0"DOOR ELEVATION (MANUAL)12SCALE:1" = 1'-0"EXTERIOR POWER DOOR CONTROL LOCATIONS14DATE:DRAWN:REVIEWED:PROJECT NO:SCALE:OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVEDSHEET TITLE:SHEET NO:SEAL AND STAMP:CONSULTANTS:PROJECT:CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO -NEW JERSEY - NEW YORK6083 Bristol ParkwayCulver City, CA 9023018600 MacArthur Blvd., Suite 100 Irvine, CA 92612515 South Flower Street, Suite 1200Los Angeles, CA 90071T 310.553.3252T 949.724.8958T 213.929.1400DRAWINGS ISSUE485C US Route 1 South, Suite 105Iselin, NJ 08830T 848.200.1200711 3rd Ave., 6th FloorNew York, NY 10017T 917.512.6688www.saaia.comT 415.390.6793NOT FOR CONSTRUCTIONIF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USINGRECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENTACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.575 Market Street, #502San Francisco, CA 94105As indicatedA-0.6A04/10/24AWJN/MP634495BASE BUILDINGACCESSIBILITYSUITE 850 & 860DEMISING WALL6 E HUTTON CENTREDRIVESANTA ANA, CA 92707DATE DESCRIPTION DELTA05/17/24 ISSUE FOR PLANNING05/20/24 ISSUE FOR PLAN CHECKNELSONALGAZENo. C-21090REN. 03/31/2025L,CENSE' ARC+,7EC7S7A7E O) CAL,)ORN,A6 E Hutton Center Dr # 850 &860 - 101119469-707/24/2024
|