Laserfiche WebLink
T <br />B <br />J <br />B <br />B <br />B+12"B <br />B <br />B <br />J <br />POWER/ VOICE/ DATA LEGEND <br />WALL MOUNTED DUPLEX ELECTRICAL OUTLET. SEE ENGINEER'S DRAWINGS FOR CONDUIT SIZE. <br />SWITCHES AND RECEPTACLES <br />1. ALL SWITCHES AND RECEPTACLES AT P-1 AND/OR WHITE WALLS SHALL BE WHITE CREWLESS, U.O.N. GC TO <br />CONFIRM COLOR FINISH ON ALL SUCH COMPONENTS AT NON-WHITE WALLS WITH ARCHITECT BEFORE <br />PURCHASE AND INSTALLATION. <br />2. ALL SWITCHES (ROCKER AND DIMMER) AND RECEPTACLES AT WALLS RECEIVING WALLCOVERING SHALL BE <br />CREWLESS. GC TO CONFIRM COLOR WITH ARCHITECT BEFORE PURCHASE AND INSTALLATION. SUBMIT SAMPLES <br />OF SWITCHES, OUTLETS AND PLATES FOR APPROVAL. <br />3. ALL RECEPTACLES INSIDE VENEERED MILLWORK SHALL BE CREWLESS BLACK, U.O.N. <br />4. ALL RECEPTACLES INSIDE WHITE MILLWORK SHALL BE WHITE CREWLESS, U.O.N. <br />5. ALL RECEPTACLES AND SWITCHES AT BACK-PAINTED GLASS WHERE OCCURS SHALL BE SSTL, U.O.N. COMPONENTS <br />SHALL BE MOUNTED HORIZONTALLY. <br />6. ALL RECEPTACLES AT METAL SURFACES SHALL BE MOUNTED HORIZONTALLY, U.O.N.. <br />7. DEDICATED SWITCHES SHALL BE ORANGE OUTLET WITH WHITE OR SSTL PLATES. <br />8. GC SHALL BE RESPONSIBLE FOR CONFIRMING RECEPTACLE TYPES FOR SPECIAL EQUIPMENT (SUCH AS COPY <br />MACHINES)WITH CLIENT AND ARCHITECT BEFORE PURCHASE AND INSTALLATION. <br />9. ALL VOICE AND DATA OUTLETS SHALL MATCH POWER OUTLETS AS ABOVE U.O.N. <br />10. ALL DIMMER SWITCHES SHALL MATCH POWER SWITCHES AS ABOVE U.O.N. <br />11. SWITCHES AND RECEPTACLES MAY BE LEVITE DECOR, GLUTTON, OR COOPER, U.O.N. <br />12. SUBMIT SAMPLES OF SWITCHES AND PLATES FOR APPROVAL. <br />13. ELECTRICAL CODE - NC 210.71 RECEPTACLE OUTLETS REQUIRED. MEETING ROOMS. <br />DESIGN CRITERIA NOTES <br />J <br />WALL MOUNTED QUADPLEX ELECTRICAL OUTLET. SEE ENGINEER'S DRAWINGS FOR CONDUIT SIZE. <br />WALL MOUNTED DUPLEX ELECTRICAL OUTLET, SEPARATE CIRCUIT. SEE ENGINEER'S DRAWINGS FOR CONDUIT SIZE. <br />FLUSH FLOOR MOUNTED FIRE RATED JUNCTION BOX, TELE/DATA AND DUPLEX OUTLET. VERIFY CONDUIT SIZE FOR <br />DATA/TELE REQUIREMENTS. COORDINATE LOCATION W/ TENANT AND FURNITURE CONTRACTOR REQUIREMENTS. <br />WALL POWER IN-FEED JUNCTION BOX FOR WORKSTATIONS POWER AND TELEPHONE/DATA. VERIFY POWER <br />REQUIREMENTS WITH THE FURNITURE VENDER AND THE ELECTRICAL DRAWINGS FOR THE NUMBER OF CIRCUITS <br />TO BE PROVIDED. AT DATA/PHONE PROVIDE A DOUBLE GANG TELEPHONE BOX WITH SINGLE GANG MUD RING. <br />PROVIDE 1-1/2" CONDUIT WITH PULL STRING AND STUB-UP AT +6" ABOVE THE CEILING WITH A SUPER FLEX <br />CONDUIT, UNLESS OTHERWISE NOTED ON PLAN. EXACT LOCATIONS & POWER REQUIREMENTS TO BE DETERMINED <br />BY TENANT'S FURNITURE VENDOR. <br />TELE COMMUNICATIONS/DATA WALL OUTLET. PROVIDE EMPTY J-BOX OR PLASTER RING & 1 1/4" DIA. EMPTY EMT <br />CONDUIT STUBBED-UP @+/-6" ABOVE SUSP. CLG. W/ PROTECTIVE PLASTIC RING & PULL STRING/ TENANT'S <br />VENDOR TO PROVIDE COVER PLATES AND PLENUM RATED CABLES. VERIFY SIZE OF CONDUIT WITH <br />CABLING/PHONE VENDOR OR WHEN FEEDING MORE THAN (1) LOCATION. <br />NEW WALL MOUNTED JUNCTION BOX. PLUS HEIGHT INDICATES HEIGHT IF NOT STANDARD. PROVIDE A SINGLE 20 <br />AMP CIRCUIT FOR HARDWARE CONNECTION OF EQUIPMENT. ELECT. SUB-CONTRACTOR IS TO CONNECT DEVICE. <br />WHERE PLUS HEIGHT IS INDICATED, HEIGHT IF NOT STANDARD. REFER TO TYPICAL SHEET NOTE 5 FOR MOUNTING <br />HEIGHT INFORMATION. <br />TYPICAL <br />NOTE: <br />POWER/ VOICE/ DATA KEYNOTES <br />ALL POWER RECEPTACLES WITHIN 6'-0" OF SINK SHALL BE GFI. <br />EXISTING CIRCUIT FOR TENANT'S TELEPHONE EQUIPMENT. <br />EXISTING FIRE TREATED BACKBOARD WITH 2" DIA. HOME RUN CONDUIT TO BASE BUILDING TELEPHONE <br />ROOM PAINTED TO MATCH WALL. <br />TENANT'S FURNITURE VENDOR TO PROVIDE DIMENSIONS FOR FURNITURE FEEDS AND TO APPROVE <br />LOCATIONS IN FIELD PRIOR TO INSTALLATION. <br />WALL MOUNTED QUADPLEX ELECTRICAL OUTLET, SEPARATE CIRCUIT. SEE ENGINEER'S DRAWINGS FOR CONDUIT <br />SIZE. <br />N INDICATES NEW OUTLET. <br />3.1 <br />3.2 <br />PROVIDE SEPARATE CIRCUIT CONFIGURATION FOR TENANT'S REFRIGERATOR. VERIFY ELECTRICAL <br />REQUIREMENTS AND SIZE WITH TENANT. <br />3.3 <br />NEW ELECTRICAL INSTA-HOT WATER HEATER, CHRONOMITE OR APPROVED EQUAL. PROVIDE DEDICATED <br />CIRCUIT AND VERIFY ELECTRICAL REQUIREMENTS. <br />3.4 <br />NEW UNDER COUNTER GARBAGE DISPOSAL WITH ON/OFF SWITCH AT +44" A.F.F., INSINKERATOR OR <br />APPROVED EQUAL. PROVIDE DEDICATED CIRCUIT AND VERIFY ELECTRICAL REQUIREMENTS. <br />3.5 <br />PROVIDE SEPARATE CIRCUIT @ +44" A.F.F. FOR TENANT'S COFFEE MAKER. VERIFY ELECTRICAL <br />REQUIREMENTS. <br />PROVIDE SEPARATE CIRCUIT @ +44" A.F.F. FOR TENANT'S MICROWAVE OVEN. VERIFY ELECTRICAL <br />REQUIREMENTS. <br />NEW ADA COMPLIANT DISHWASHER, ASKO #DBI663IS. PROVIDE DEDICATED CIRCUIT AND VERIFY <br />ELECTRICAL REQUIREMENTS. <br />3.6 <br />3.7 <br />3.8 <br />3.9 <br />3.10 <br />+66" <br />+66" <br />+78" +78" <br />+44"+44"+44" <br />+66" <br />+66" <br />TV <br />RECEPTION <br />600 <br />CONFERENCE <br />601 <br />OPEN BREAK AREA <br />602 <br />OFFICE <br />603 <br />COLLABORATION AREA <br />605 <br />OFFICE <br />606 <br />OFFICE <br />607 <br />OFFICE <br />608 <br />OFFICE <br />609 <br />OFFICE <br />610 <br />COPY/PRINT <br />611 <br />IT/STORAGE <br />612 <br />QUIET RM. <br />613 <br />COFFEE BAR <br />614 <br />OFFICE <br />616 <br />OFFICE <br />617 <br />CONFERENCE <br />618 <br />OFFICE <br />619 <br />OPEN WORK AREA <br />615 <br />OPEN WORK AREA <br />621 <br />3.1 <br />3.2 <br />+44"3.4 <br />3.5 <br />NN <br />N <br />N <br />N <br />N(4) <br />(4) <br />N(4) <br />(4) <br />(2) <br />(2)N <br />(E) ELEVATOR LOBBY <br />(E) FREIGHT <br />ELEV. LOBBY <br />(E) MEN'S <br />RESTROOM <br />(E) WOMEN'S <br />RESTROOM <br />(E) JANITOR'S <br />CLOSET <br />OPEN WORK AREA <br />604 <br />N(2) <br />(2) <br />3.6 <br />+44" <br />3.3 <br />TV <br />(10) <br />OFFICE <br />620 <br />N <br />(2)(2) <br />N N +66" <br />+66" <br />N <br />N <br />N <br />N <br />N <br />N <br />3.7 <br />3.8 3.9 <br />3.10 <br />3.10 <br />3.10 <br />3.10 <br />3.10 <br />N <br />SUITE 600 <br />TENANT'S EXPANSION SPACE <br />TENANT'S EXPANSION SPACETENANT'S EXISTING SPACE TENANT'S EXISTING SPACEN <br />+66" <br />TV <br />N <br />N <br />N <br />N <br />SUITE 625 <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY -IRVINE -LOS ANGELES -SAN FRANCISCO - <br />NEW JERSEY -NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS.SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS.ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-3.0 <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />POWER / VOICE / DATA <br />PLAN <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />DATE DESCRIPTION DELTA <br />04/16/24 ISSUE FOR ENGINEERING <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />SCALE: <br />1/8" = 1'-0"POWER/VOICE/DATA PLAN 1 <br />N <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025L,CEN S E ' ARC+,7 <br />E <br />C7S7A <br />7 <br />E O) CA L ,)O RN,A6 E Hutton Center Dr <br />Unit# 625 & 6509/23/2024