Laserfiche WebLink
REFLECTED CEILING LEGEND <br />DESIGN CRITERIA NOTES <br />FIRE AND LIFE SAFETY COMPONENTS <br />1. ALL COMPONENTS SHALL BE WHITE U.O.N. <br />2. FIRE PULL COMPONENTS SHALL BE RED OR OTHER ACCORDING TO LOCAL JURISDICTION. <br />3. ALL STROBES SHALL BE CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC CEILING TILES WHERE <br />OCCURS, U.O.N. <br />4. ALL SPEAKERS SHALL BE FULLY RECESSED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC CEILING <br />TILES WHERE OCCURS, U.O.N. <br />5. ALL SPRINKLER HEADS SHALL BE FULLY CONCEALED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC <br />CEILING TILES WHERE OCCURS, U.O.N. WHERE BUILDING STANDARD IS SEMI-CONCEALED, HEADS AT GWB <br />CEILINGS SHALL BE FULLY CONCEALED. <br />6. COMPONENTS SHALL BE MOUNTED WITH CONSISTENT CENTERLINE, U.O.N. <br />GENERAL <br />1. ALL LINEAR DIFFUSERS SHALL BE FRAMELESS (MUD FLANGED) AT ALL GWB CEILINGS, U.O.N. GC SHALL SUPPLY <br />AND INSTALL DIFFUSERS THE ENTIRE LENGTH AS SHOWN ON REFLECTED CEILING PLANS WHETHER AN ACTIVE OR <br />INACTIVE SECTION. PAINT CEILING PLENUM AND ALL DUCT CONNECTIONS ABOVE FIXTURE MATTE BLACK, U.O.N. <br />2. PROVIDE AND INSTALL PERFORATED CEILING GRILLE PANELS AT ALL ACOUSTIC CEILING MOUNTED SUPPLY AND <br />RETURN LOCATIONS, U.O.N. CONFIRM COLOR OF GRILLE WITH ARCHITECT BEFORE PURCHASE AND <br />INSTALLATION. <br />3. U.O.N., PROVIDE SHADOW MOLDING AT ALL WALL CONNECTIONS. <br />REFLECTED CEILING KEYNOTES <br />PATCH/REPAIR/REPLACE DAMAGED OR MISSING CEILING TILE THROUGHOUT, TYP. <br />PROVIDE NEW DRYWALL HEADER. SEE DETAIL #7/A-30.2 <br />AREA NOT IN CONTRACT (N.I.C.) <br />EXISTING 2X2 CEILING GRID AND TILE IS TO REMAIN. THE G.C. IS TO REPLACE ANY <br />BROKEN OR DAMAGED TILES IN THE AREA OF WORK AND IS TO REPLACE ANY <br />DAMAGED BY NEW CONSTRUCTION. <br />CEILING MOUNTED EXIT SIGN. DARK QUADRANT INDICATES FACE. ARROW(S) INDICATE <br />DIRECTION. <br />±X' - XX" <br />N <br />E <br />R <br />CEILING HEIGHT AS INDICATED. <br />INDICATES NEW LIGHT FIXTURE. <br />INDICATES EXISTING LIGHT FIXTURE TO REMAIN. <br />INDICATES EXISTING LIGHT FIXTURE TO BE REMOVED OR RELOCATED. <br />4.1 <br />4.2 <br />NEW 2X2 CEILING SYSTEM AT TENANT'S EXPANSION SUITE <br />CEILING GRID <br />MANUFACTURER: EXISTING TO REMAIN <br />SIZE: 2X2 <br />SERIES: EXISTING TO REMAIN <br />COLOR: EXISTING TO REMAIN <br />CEILING TILE <br />MANUFACTURER: MATCH EXISTING TO CURRENT SUITE <br />SERIES: MATCH EXISTING TO CURRENT SUITE <br />SIZE: MATCH EXISTING TO CURRENT SUITE <br />COLOR: MATCH EXISTING TO CURRENT SUITE <br />REFERENCE SHEET A-30.2 FOR SPECIFICATIONS AND REQUIREMENTS. <br />LIGHTING SCHEDULE <br />MARK FIXTURE TYPE MANUFACTURER CATALOG NUMBER LAMP REMARKS <br />LF-1 <br />LF-X <br />2x4 LED <br />DIRECT/INDIRECT METALUX 24SR-LD2-39-C-UNV-L835-CD1-U LED <br />COOPER LIGHTING ESH6 / EST61GMX <br />CEILING MOUNTED <br />RECESSED EXIT SIGN <br />3,500 COLOR TEMP; VERIFY COLOR TEMPS PER BUILDING STANDARDS. MATCH EXISTING <br />MATCH EXISTING TO REMAIN.LED <br />(E) ELEVATOR LOBBY <br />(E) FREIGHT <br />ELEV. LOBBY <br />(E) MEN'S <br />RESTROOM <br />(E) WOMEN'S <br />RESTROOM <br />(E) JANITOR'S <br />CLOSET <br />RECEPTION <br />600 <br />CONFERENCE <br />601 <br />OPEN BREAK AREA <br />602 <br />OFFICE <br />603 <br />OPEN WORK AREA <br />604 <br />COLLABORATION AREA <br />605 <br />OFFICE <br />606 <br />OFFICE <br />607 <br />OFFICE <br />608 <br />OFFICE <br />609 <br />OFFICE <br />610 <br />COPY/PRINT <br />611 <br />IT/STORAGE <br />612 <br />QUIET RM. <br />613 <br />COFFEE BAR <br />614 <br />OFFICE <br />616 <br />OFFICE <br />617 <br />CONFERENCE <br />618 <br />OFFICE <br />619 <br />OPEN WORK AREA <br />615 <br />OPEN WORK AREA <br />621 <br />N <br />EEE <br />EEE <br />EEE <br />EEE <br />EEE <br />EEE <br />EEE <br />E <br />E <br />E <br />E <br />E <br />EE <br />E E E E <br />E E <br />EE <br />E E <br />E <br />E <br />E E <br />E E <br />EE <br />EE <br />E E <br />E <br />EE <br />E <br />E <br />E E <br />E <br />4.1 <br />THROUGHOUT <br />4.1 <br />THROUGHOUT <br />4.1 <br />THROUGHOUT <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N N N <br />N N <br />N N <br />N N <br />N N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N <br />N N <br />N N <br />N <br />R <br />N <br />N <br />N <br />LF-X <br />E <br />E <br />E <br />E <br />E <br />E <br />4.2 <br />±9' - 0" <br />OFFICE <br />620 <br />EEEE <br />SUITE 600 <br />TENANT'S EXPANSION SPACE <br />TENANT'S EXPANSION SPACETENANT'S EXISTING SPACE TENANT'S EXISTING SPACEN <br />LF-1 <br />LF-1 <br />LF-1 <br />LF-1 <br />LF-1 <br />LF-1LF-1 <br />LF-1 <br />LF-1 LF-1 <br />LF-1 LF-1 <br />LF-1LF-1LF-1 <br />±8' -11" <br />LF-1 <br />LF-1 LF-1 LF-1 LF-1 <br />LF-1LF-1LF-1LF-1LF-1 <br />LF-1 LF-1 LF-1 LF-1 LF-1 <br />LF-1LF-1LF-1 <br />LF-1 <br />LF-1 LF-1 <br />LF-1 <br />LF-1 <br />LF-1 <br />LF-X <br />LF-X <br />LF-1 <br />LF-X <br />SUITE 625 <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY -IRVINE -LOS ANGELES -SAN FRANCISCO - <br />NEW JERSEY -NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS.SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS.ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-4.0 <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />REFLECTED CEILING PLAN <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />DATE DESCRIPTION DELTA <br />04/16/24 ISSUE FOR ENGINEERING <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />SCALE: <br />1/8" = 1'-0"REFLECTED CEILING PLAN 1 <br />N <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025L,CEN S E ' ARC+,7 <br />E <br />C7S7A <br />7 <br />E O) CA L ,)O RN,A6 E Hutton Center Dr <br />Unit# 625 & 6509/23/2024