My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6 E Hutton Center Dr Unit# 625 & 650 - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hutton Center Dr
>
6 E Hutton Center Dr Unit# 625
>
6 E Hutton Center Dr Unit# 625 & 650 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2025 7:39:21 AM
Creation date
6/10/2025 7:39:17 AM
Metadata
Fields
Template:
Plan
Permit Number
101119634
101119635
Full Address
6 E Hutton Center Dr Unit# 625
6 E Hutton Center Dr Unit# 650
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PARTITION LEGENDKEYNOTES <br />TACTILE "EXIT STAIR DOWN" SIGNAGE. SEE DETAIL #2 <br />TACTILE STAIR LEVEL IDENTIFICATION SIGNAGE. SEE DETAIL #3 <br />#1. A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" SHALL IDENTIFY EACH EXIT ACCESS DOOR FROM <br />AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN. <br />EXIT <br />ROUTE <br />CORRESPONDING <br />GRADE II BRAILLE <br />LINE OF FINISHED FLOOR <br />48" MIN.60" MAX.#2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY SHALL <br />BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE "EXIT STAIR DOWN" <br />EXIT <br />STAIR <br />DOWN <br />CORRESPONDING <br />GRADE II BRAILLE <br />LINE OF FINISHED FLOOR <br />48" MIN.60" MAX.#3. A TACTILE SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: "LEVEL #" **AT EXIT DISCHARGE, SIGN <br />SHALL HAVE RAISED FIVE-POINTED STAR TO LEFT OF IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF <br />STAIR SHALL BE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. PROVIDE ROOF ACCESS/NO ROOF ACCESS <br />AS REQUIRED. <br />STAIR 01 <br />LEVEL1 <br />CORRESPONDING <br />GRADE II BRAILLE <br />1" HIGH <br />LINE OF FINISHED FLOOR60" MAX.1 1/2" TEXT <br />5" TEXT12" MIN.18" MIN.EXISTING PARTITION <br />EXISTING DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT <br />LOCATION SHOWN. <br />NEW PARTITION <br />AREA NOT IN CONTRACT (N.I.C.) <br />COMMON PATH OF TRAVEL <br />EGRESS PATH OF TRAVEL <br />CEILING MOUNTED EXIT SIGN. DARK QUADRANT INDICATES FACE. <br />ARROW(S) INDICATE DIRECTION. LITHONIA LRP-GMR, EDGE LIT, TOP <br />MOUNTED WITH SILVER INSERTS. <br />ACCESSIBLE COMMON PATH OF TRAVEL <br />1 <br />2 <br />3 <br />TACTILE "EXIT ROUTE" SIGNAGE. SEE DETAIL #1 <br />SFEC BUILDING STANDARD SEMI-RECESSED FIRE EXTINGUISHER CABINET <br />TACTILE EXIT SIGNS <br />TACTILE EXIT SIGN <br />PERMANENT SIGNAGE TO BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR AT +48" A.F.F. <br />MIN MEASURED TO THE BASELINE LOWEST LINE OF BRAILLE AND 60" A.F.F. MAX MEASURED TO THE BASELINE OF THE <br />HIGHEST LINE OF THE RAISED CHARACTERS. MOUNTED LOCATION MUST ALLOW A PERSON TO APPROACH WITHOUT <br />ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN SWING PATH OF THE DOOR [11B-307 (PROTRUDING <br />OBJECTS); SEC. 1013.4 AND 11B-703 (TACTILE EXIT SIGNAGE)] <br />LETTERS & NUMBERS SHALL BE RAISED 1/32", <br />UPPER CASE, SANS SELF TYPE AND SHALL BE <br />ACCOMPANIED WITH GRADE II BRAILLE RAISED <br />CHARACTERS. SHALL BE AT LEAST 5/8" HIGH, <br />BUT NO HIGHER THAN 2" CHARACTERS AND <br />BRAILLE SHALL BE IN HORIZONTAL FORMAT <br />AND WITH BRAILLE PLACED 3/8" MIN AND 1/2" <br />MAX DIRECTLY BELOW THE TACTILE <br />CHARACTERS; FLUSH LEFT OR CENTERED. <br />EXIT <br />EQ EQ <br />60" MAX.CORRESPONDING <br />GRADE II BRAILLE <br />48" MIN..NOTES <br />1. SIGNS W/ RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48" MINIMUM ABOVE FINISH FLOOR OR <br />GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE & 60" MAXIMUM <br />ABOVE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF <br />RAISED CHARACTERS. MOUNTING LOCATION SHALL BE BEYOND THE ARC OF THE DOOR SWING BETWEEN THE <br />CLOSED POSITION AND THE 45 DEGREE OPEN POSITION. <br />2. RAISED CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE <br />LETTER "O" IS 60% MINIMUM AND 110% MAXIMUM OF THE HEIGHT OF THE UPPERCASE "T". STROKE <br />THICKNESS OF THE UPPERCASE "T" SHALL BE 15% MAXIMUM OF THE HEIGHT OF THE CHARACTER. <br />CHARACTERS SHALL BE UPPER CASE & SANS SERIF OR SIMPLE SERIF. <br />LITERARY BRAILLE STANDARD DIMENSIONS <br />DOT DIAMETER - .059" HORIZONTAL SEPARATION BETWEEN CELLS -.241" <br />INTER-DOT SPACING - .090" VERTICAL SEPARATION BETWEEN CELLS -.395" <br />12"60"NOTE: ALL SIGNAGE SHALL COMPLY WITH 2022 CBC 11B-703. <br />INTERNATIONAL <br />SYMBOL OF <br />ACCESSIBILITY (ISA) <br />PER CBC 11B-703.7.2.1 <br />RECEPTION <br />600 <br />CONFERENCE <br />601 <br />OPEN BREAK AREA <br />602 <br />OFFICE <br />603 <br />COLLABORATION AREA <br />605 <br />OFFICE <br />606 <br />OFFICE <br />607 <br />OFFICE <br />608 <br />OFFICE <br />609 <br />OFFICE <br />610 <br />COPY/PRINT <br />611 <br />IT/STORAGE <br />612 <br />QUIET RM. <br />613 <br />COFFEE BAR <br />614 <br />OFFICE <br />616 <br />OFFICE <br />617 <br />CONFERENCE <br />618 <br />OFFICE <br />619 <br />OPEN WORK AREA <br />615 <br />OPEN WORK AREA <br />621 <br />(E) ELEVATOR LOBBY <br />(E) FREIGHT <br />ELEV. LOBBY <br />(E) MEN'S <br />RESTROOM <br />(E) WOMEN'S <br />RESTROOM <br />(E) JANITOR'S <br />CLOSET <br />OPEN WORK AREA <br />604 <br />OFFICE <br />620 <br />40'-4" <br />21'-7" LF <br />TO EXIT #1 <br />EXIT #1 <br />EXIT #2 <br />1 <br />2 <br />3 <br />1 <br />1 <br />167'-5" LF TO EXIT #2110' - 8"191' <br /> - 6"2 <br />63'-2" LF TO EXIT #2 <br />45'-1" 106'-10" LF TO EXIT #13 <br />SUITE 600 <br />SUITE 650 <br />18" MIN. <br />12" MIN. <br />(E) <br />SFEC <br />(E) <br />SFEC <br />(N) <br />SFEC <br />SUITE 625 <br />9 8 ' - 4 " <br />89'-9" <br />13'-2" LF TO EXIT #2 158'-3" LF TO EXIT #1 <br />A-0.7 <br />1 <br />USE: B -OFFICE <br />3,473 SF <br />LOAD FACTOR = 150 <br />OL = 24 OCCUPANTS <br />EXIT PROVIDED = 1 <br />EXIT REQUIRED = 1 <br />TOTAL: 6,837 SF <br />USE: B -OFFICE <br />6,517 SF (95% OF 6,837 SF) <br />LOAD FACTOR = 150 <br />OL = 44 OCCUPANTS <br />USE : B -CONFERENCE <br />320 SF (5% OF 6,837 SF) <br />LOAD FACTOR = 15 <br />OL = 22 OCCUPANTS <br />TOTAL OL = 66 OCCUPANTS <br />EXIT PROVIDED = 2 <br />EXIT REQUIRED = 3 <br />SCALE: <br />NTSSYMBOL OF ACCESSIBILITY SIGNAGE 5 <br />OCCUPANT CALCULATION <br />EXIT CALCS SPRINKLERED BUILDING <br />MAXIMUM TOTAL # OF OCCUPANTS FOR SUITE 650 <br />TOTAL OCCUPANT SQUARE FOOTAGE <br /># OF EXITS REQUIRED FOR TABLE 1006.3.3 <br /># OF EXITS FOR SUITE <br />131 <br />±6,910 <br />2 <br />3 <br />REQUIRED EXIT WIDTH (INCHES) <br />REQUIRED STAIR WIDTH (INCHES) <br />72" PROVIDED** <br />88" PROVIDED <br />0.2 X (131+66+24) = 44.2" <br />REQUIRED <br />0.3 X (131+66+24) = 66.3" <br />REQUIRED <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY -IRVINE -LOS ANGELES -SAN FRANCISCO - <br />NEW JERSEY -NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS.SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS.ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-0.5C <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />EXIT ROUTES AND TACTILE <br />SIGNAGE <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />*NOTE: PER CBC 303.1.2 SMALL ASSEMBLY SPACES <br />THE FOLLOWING ROOMS AND SPACES SHALL NOT BE CLASSIFIED AS ASSEMBLY OCCUPANCIES: <br />1. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS AND <br />ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY. <br />2. A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES THAT IS LESS THAN 750 SQUARE FEET (70M²) IN AREA AND <br />ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY. <br />**NOTE: PER CBC 1005.7.1 DOORS <br />3.DOORS, WHEN FULLY OPENED, SHALL NOT REDUCED THE REQUIRED WIDTH BY MORE THAN 7 INCHES (178 MM). <br />DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF. <br />EXIT ANALYSIS - SUITE 650 <br />111 ROOM NUMBER SQUARE FOOTAGE LOAD FACTOR OCCUPANT LOAD <br />RECEPTION 600 276 SF 15 19 <br />CONFERENCE 601 392 SF 15 27 <br />OPEN BREAK AREA 602 198 SF 15 14 <br />OFFICE 603 149 SF 150 1 <br />OPEN WORK AREA 604 1745 SF 150 12 <br />COLLABORATION AREA 605 803 SF 150 6 <br />OFFICE 606 132 SF 150 1 <br />OFFICE 607 132 SF 150 1 <br />OFFICE 608 127 SF 150 1 <br />OFFICE 609 141 SF 150 1 <br />OFFICE 610 140 SF 150 1 <br />COPY/PRINT 611 127 SF 150 1 <br />IT/STORAGE 612 42 SF 300 1 <br />QUIET RM.613 44 SF 150 1 <br />COFFEE BAR 614 216 SF 15 15 <br />OPEN WORK AREA 615 551 SF 150 4 <br />OFFICE 616 120 SF 150 1 <br />OFFICE 617 131 SF 150 1 <br />CONFERENCE 618 197 SF 15 14 <br />OFFICE 619 125 SF 150 1 <br />OFFICE 620 119 SF 150 1 <br />OPEN WORK AREA 621 1005 SF 150 7 <br />DATE DESCRIPTION DELTA <br />04/16/24 ISSUE FOR ENGINEERING <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />08/07/24 PCC 01 A <br />08/26/24 PCC 02 B <br />SCALE: <br />1/8" = 1'-0"EXIT ROUTES AND TACTILE SIGNAGE -6TH FLOOR 1 <br />N <br />OCCUPANT CALCULATION <br />MAXIMUM TOTAL # OF OCCUPANTS FOR SUITE 600 <br />TOTAL OCCUPANT SQUARE FOOTAGE <br /># OF EXITS REQUIRED FOR TABLE 1006.3.3 <br /># OF EXITS FOR SUITE <br />66 <br />±6,837 <br />2 <br />3 <br />EXIT ANALYSIS -SUITE 600 <br />USE <br />OFFICES <br />OCCUPANT LOAD <br />±6,517 <br />SQUARE FOOTAGE LOAD FACTOR <br />150 44 <br />OCCUPANT CALCULATION <br />MAXIMUM TOTAL # OF OCCUPANTS FOR SUITE 625 <br />TOTAL OCCUPANT SQUARE FOOTAGE <br /># OF EXITS REQUIRED FOR TABLE 1006.3.3 <br /># OF EXITS FOR SUITE <br />24 <br />±3,473 <br />1 <br />1 <br />EXIT ANALYSIS -SUITE 625 <br />USE <br />OFFICES <br />OCCUPANT LOAD <br />±3,473 <br />SQUARE FOOTAGE LOAD FACTOR <br />150 24 <br />CONFERENCE ±320 150 22 <br />B <br />B <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025L,CEN S E ' ARC+,7 <br />E <br />C7S7A <br />7 <br />E O) CA L ,)O RN,A6 E Hutton Center Dr <br />Unit# 625 & 6509/23/2024
The URL can be used to link to this page
Your browser does not support the video tag.