Laserfiche WebLink
1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" )15" MIN..48" MAX.10" MAX. <br />UNOBSTRUCTED SIDE REACH15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH <br />(A) <br />(C) <br />(B) <br />(D) <br />48" MIN. <br />48" MIN. <br />48" MIN.48" MIN.27" MAX.X<80"GUARDRAIL OR BARRIER <br />NOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL <br />IN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A HAZARD, THE <br />EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROM <br />THE DIRECTION OF THE STAIR FLIGHT. <br />11B-505.5 <br />11B-505.6 <br />11B-504.4.1 <br />11B-505.2 <br />CONTRASTING COLOR STRIPE SHALL BE 2"-4" WIDE, POSITIONED PARALLEL TO AND <br />NOT MORE THAN 1" AWAY FROM THE NOSE. THE STRIPE SHALL EXTEND THE FULL <br />WIDTH OF THE STEP AND SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP <br />RESISTANT AS THE REST OF THE TREADS. PAINTED STRIPES ARE ACCEPTABLE. <br />GROOVES ARE NOT ACCEPTABLE. <br />WHERE REQUIRED: <br />1.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND THE LOWER <br />TREAD MARKED BY A COLOR STRIPE PROVIDING CLEAR VISUAL CONTRAST. <br />2.EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS <br />MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. <br />PROVIDE <br />CONTINUOUS <br />HANDRAILS ON BOTH <br />SIDES OF THE STAIRS <br />FOR THE FULL LENGTH <br />OF EACH STAIR FLIGHT <br />HANDRAIL EXTENSIONS MUST BE PROVIDED <br />AT THE TOP AND BOTTOM OF EACH STAIR FLIGHT AND MUST <br />RETURN TO A WALL, GUARD, OR THE LANDING SURFACE OR SHALL <br />BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT <br />NOTE: INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS <br />SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS <br />1 1/2" <br />MIN.1 1/2"MIN.1" MAX.2"-4" <br />CONTRASTING COLOR STRIP <br />11B-504.4.1 <br />11B-505.10 <br />11B-505.10 <br />(B) SECTION/ELEVATION(B-ALT) ALT. SECTION/ELEVATION 34" - 38" <br />PLUS (1) TREAD <br />DEPTH MIN12". <br />12" <br />MIN. <br />11" MIN. <br />UNIFORM <br />TREAD DEPTH <br />4"-7" <br />UNIFORM <br />RISER HEIGHT <br />X<27" <br />12" <br />MIN <br />NOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE <br />HANDRAIL IN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A <br />HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90 <br />DEGREES FROM THE DIRECTION OF THE STAIR FLIGHT. <br />11B-505.10 <br />11B-505.10 11B-505.10 <br />11B-505.7.1 <br />4"-6 1/4" PERIMETER <br />4"-6 1/4" PERIMETER <br />(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE) <br />2 1/4"2 1/4"11B-505.7.2 <br />*EXCEPTIONS <br />1. THE CLEAR WIDTH SHALL BE PERMITTED TO BE <br />REDUCED TO 32" MIN. FOR A LENGTH OF 24" MAX. <br />PROVIDED THAT REDUCED WIDTH SEGMENTS ARE <br />SEPARATED BY SEGMENTS THAT ARE 48" LONG MIN. <br />AND 36" WIDE MIN. <br />2. THE CLEAR WIDTH FOR WALKING SURFACES IN <br />CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR <br />MORE SHALL BE 44" MIN. <br />3. THE CLEAR WIDTH FOR SIDEWALKS AND WALKS <br />SHALL BE 48" MIN.. WHEN, BECAUSE OF <br />RIGHT-OF-WAY RESTRICTIONS, NATURAL BARRIERS <br />OR OTHER EXISTING CONDITIONS, THE ENFORCING <br />AGENCY DETERMINES THAT COMPLIANCE WITH THE <br />48" CLEAR SIDEWALK WIDTH WOULD CREATE AN <br />UNREASONABLE HARDSHIP, THE CLEAR WIDTH MAY <br />BE REDUCED TO 36". <br />4. THE CLEAR WIDTH FOR AISLES SHALL BE 36" MIN. IF <br />SERVING ELEMENTS ON ONLY ONE SIDE, AND 44" <br />MIN. IF SERVING ELEMENTS ON BOTH SIDES. <br />5. THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO <br />ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44" <br />EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR <br />SWINGS. <br />(B) EXCEPTION 1 <br />(A) MINIMUM CLEAR WIDTH, MAX. SLOPE <br />2.0% MAX. <br />5.0% MAX. <br />(TYP <br />U.O.N.)36" MIN.*36" MIN.*32" MIN.24" MAX.48" MIN. 24" MAX. <br />11B-403.5.1 <br />(A) FORWARD APPROACH48" MIN.30 MIN.30" MIN.48" MIN. <br />(B) PARALLEL APPROACH <br />(1) THE CLEAR FLOOR SPACE (CFS) MUST BE STABLE, <br />FIRM, AND SLIP RESISTANT. <br />(2) OPENINGS MUST NOT ALLOW THE PASSAGE OF A <br />SPHERE MORE THAN 1/2" IN DIAMETER. ELONGATED <br />OPENINGS MUST BE PERPENDICULAR TO THE <br />DOMINANT DIRECTION OF TRAVEL. <br />CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THE <br />CLEAR FLOOR SPACE. SLOPES WITHIN THE CFS MUST BE <br />NO GREATER THAN 2% <br />THE CFS MAY INCLUDE COMPLIANT KNEE AND TOE <br />CLEARANCE. <br />ONE FULLY UNOBSTRUCTED SIDE OF THE CFS MUST <br />ADJOIN AN ACCESSIBLE ROUTE OR ANOTHER CLEAR <br />FLOOR OR GROUND SPACE <br />11B-305.5 11B-305.5 <br />11B-302.1 <br />11B-302.3 <br />11B-305.2 <br />11B-305.4 <br />11B-305.6 <br />9" MIN.8" MIN.27" MIN.11" MIN. <br />25" MAX.30" MIN.(A) KNEE CLEARANCE <br />ELEVATION <br />(B) KNEE CLEARANCE <br />PLAN <br />17"-25"30" MIN.9"6" MAX. <br />(A) <br />ELEVATION <br />(B) <br />PLAN <br />11B-306.3 11B-306.3 <br />11B-306.2 11B-306.2 <br />>10"-24" MAX.34" MAX.46" MAX.34" MAX.48" MAX.10" MAX. <br />(a) (b)48" MAX.20" MAX.>20"-25" MAX 44" MAX.(a) (b) <br />OBSTRUCTED HIGH FORWARD REACH <br />OBSTRUCTED HIGH SIDE REACH <br />11B-308.2.1 11B-308.3.1 <br />11B-308.2.2 <br />11B-308.3.2X≥80"4" MAX.X>27"12" MAX.27" - 80" <br />12" MAX.27" MAXX>12"X>12"80" MIN.LIMITS OF PROTRUDING OBJECTS <br />(A)(B) <br />POST-MOUNTED PROTRUDING OBJECTS <br />11B-307.2 <br />11B-307.3 <br />(A) FRONT APPROACH, PULL SIDE <br />(B) FRONT APPROACH, PUSH SIDE <br />(C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PUSH SIDE <br />(E) LATCH APPROACH, PULL SIDE (F) LATCH APPROACH, PUSH SIDE <br />18" <br />MIN.60" MIN.48" MIN.ADD 12" IF A CLOSER AND <br />LATCH ARE PROVIDED <br />ADD 6" AT EXTERIOR SIDE <br />OF EXTERIOR DOORS <br />60" MIN.36" MIN.42" MIN.22" MIN.48" MIN.24" MIN.42" MIN.24" MIN.ADD 4" IF CLOSER AND <br />LATCH IS PROVIDED <br />11B-404.2.4.1 <br />11B-404.2.4.1 <br />11B-404.2.4.1 11B-404.2.4.1 <br />11B-404.2.4.1 11B-404.2.4.1 <br />ADD 4" IF CLOSER AND <br />LATCH IS PROVIDED <br />(A) RECESSED DOOR, PULL SIDE (B) RECESSED DOOR PUSH SIDE <br />18" <br />MIN.48" MIN.ADD 12" IF A <br />CLOSER AND <br />LATCH ARE <br />PROVIDED <br />ADD 6" AT <br />EXTERIOR SIDE <br />OF EXTERIOR <br />DOORS 60" MIN.X>8"X>8"3'-0" <br />11B-404.2.4.1 11B-404.2.4.1 <br />11B-404.2.6 11B-404.2.6 <br />11B-404.2.6 <br />11B-307.42.0% MAX2.0% MAX.RAMP DOWN 8.33% MAX.2.0% MAX2.0% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />8.3% MAX. <br />2.0% MAX. <br />8.3% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />8.3% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />2.0% MAX. <br />PROVIDE CONTINUOUS <br />HANDRAILS <br />ON BOTH SIDES OF RAMP FOR <br />THE <br />FULL LENGTH OF EACH RAMP <br />RUN <br />1 1/2" <br />MIN.1 1/2"MIN.TOP LANDING WITH A <br />CHANGE <br />IN DIRECTION SHOWN <br />PROVIDE EDGE PROTECTION AT <br />EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP <br />LANDINGS WHERE A CHANGE IN LEVEL OCCURS. <br />EXCEPTIONS: <br />1. WHERE RAMPS ARE NOT REQUIRED TO HAVE <br />HANDRAILS AND AT CURB RAMP FLAIRS NOT <br />STEEPER THAN 1:10 HAVE FLARED SIDES. <br />2.ON THE SIDES OF RAMP LANDINGS SERVING AN <br />ADJOINING RAMP RUN OR STAIR. <br />3.WHERE AN ABRUPT CHANGE IN LEVEL OF 1/2" <br />MAX. OCCURS WITHIN 10" OF THE MINIMUM <br />LANDING AREA. <br />2" - 4" HIGH EDGE PROTECTION (CURB OR BARRIER) <br />SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED <br />BARRIER ALONG THE LENGTH OF A RAMP TO PREVENT <br />WHEEL ENTRAPMENT. <br />HANDRAIL EXTENSIONS <br />MUST BE PROVIDED AT THE TOP AND BOTTOM <br />LANDINGS OF EACH RAMP RUN AND MUST <br />RETURN TO A WALL, GUARD, OR THE LANDING <br />SURFACE OR SHALL BE CONTINUOUS TO THE <br />HANDRAIL OF AN ADJACENT RAMP RUN. <br />NOTE: INSIDE HANDRAILS ON SWITCHBACK OR <br />DOGLEG RAMPS SHALL BE CONTINUOUS <br />BETWEEN FLIGHTS OR RUNS <br />HANDRAILS MAY PROJECT INTO THE <br />REQUIRED CLEAR WIDTH OF THE <br />RAMP AT EACH SIDE A MAXIMUM OF <br />3 1/2" AT THE HANDRAIL HEIGHT <br />AT LEAST AS WIDE AS THEWIDEST RAMP RUN (TYP.)60" MIN. <br />BOTTOM LANDING <br />5'-0" MINIMUM <br />INTERMEDIATE LANDING <br />(STRAIGHT) <br />5'-0" MINIMUM <br />INTERMEDIATE LANDING <br />(CHANGE IN DIRECTION)60" MINIMUMINTERMEDIATE LANDING(CHANGE IN DIRECTION)5'-0" MINIMUMTOP LANDINGRAMP RUN <br />DOWN <br />RAMP RUNDOWNRAMP RUN <br />DOWN <br />5'-0" MINIMUM <br />TOP LANDING <br />NOTES: <br />·THE CLEAR WIDTH OF A RAMP RUN MUST BE 48" MINIMUM. <br />·WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES ARE PERMITTED <br />TO OVERLAP THE REQUIRED LANDING AREA. DOORS, IN ANY POSITION, MUST NOT REDUCE THE MINIMUM <br />DIMENSION OF THE RAMP LANDING TO LESS THAN 42" <br />·LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. <br />BOTTOM LANDING <br />11B-405 <br />11B-405 <br />11B-505.10.1 <br />11B-505.10.1 <br />11B-1012.4 <br />X>27" <br />12" <br />MIN.34" - 38" <br />12" <br />MIN. <br />12" <br />MIN.30" MAX. RISE FOREACH RAMP RUN(B) HANDRAIL MOUNTING HEIGHT AND EXTENSIONS1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" ) <br />4"-6 1/4" PERIMETER <br />4"-6 1/4" PERIMETER <br />(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE) <br />2 1/4"2 1/4"CURB 2" MIN. - 4" MAX. TO <br />PREVENT THE PASSAGE OF A 4" <br />DIAMETER SPHERE <br />GUIDE RAIL POSITIONED TO PREVENT <br />THE PASSAGE OF A 4" DIAMETER SPHERE <br />(D) EDGE PROTECTION - BARRIER <br />(D) EDGE PROTECTION - CURB 43" MAX> 66"34" - 44"404.2.11 VISION LIGHTS <br />DOORS, GATES, AND SIDE LIGHTS ADJACENT TO <br />DOORS OR GATES, CONTAINING ONE OR MORE <br />GLAZING PANELS THAT PERMIT VIEWING <br />THROUGH THE PANELS SHALL HAVE THE <br />BOTTOM OF AT LEAST ONE GLAZED PANEL <br />LOCATED 43 INCHES (1090 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR. <br />EXCEPTION: VISION LIGHTS <br />WITH THE LOWEST PART <br />MORE THAN 66 INCHES <br />(1675 MM) FROM THE <br />FINISH FLOOR OR GROUND <br />SHALL NOT BE REQUIRED <br />TO COMPLY WITH <br />404.2.11. <br />404.2.10 DOOR AND GATE SURFACES <br />SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH <br />SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE <br />SURFACES SHALL BE WITHIN 1/16 INCH (1.6 MM) OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. <br />EXCEPTIONS: <br />1. SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.10. <br />2. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM <br />FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH (255 MM) BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT. <br />3. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY <br />WITH 404.2.10. <br />4. EXISTING DOORS AND GATES WITHOUT SMOOTH SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED <br />TO PROVIDE SMOOTH SURFACES COMPLYING WITH 404.2.10 PROVIDED THAT IF ADDED KICK PLATES ARE INSTALLED, CAVITIES CREATED BY SUCH KICK <br />PLATES ARE CAPPED. <br />FINISH FLOOR OR GROUND <br />7" - 8"30" - 44"5" MAX.35" MIN.2" MIN. <br />VERTICAL ACTUATION BARWHERE PUSH PLATES ARE <br />PROVIDED THERE SHALL BE <br />TWO PUSH PLATES <br />PUSH PLATE 4" <br />SQUARE OR 4 " <br />DIAMETER MINIMUM <br />INT'L SYMBOL OF <br />ACCESSIBILITY, <br />TYPICAL. <br />SCALE: <br />3/8" = 1'-0"STAIRWAYS 13 <br />SCALE: <br />1/4" = 1'-0"ACCESSIBLE ROUTE MIN. WIDTH 1 <br />SCALE: <br />1/4" = 1'-0"REQUIRED CLEAR FLOOR SPACE 5 <br />SCALE: <br />3/8" = 1'-0"KNEE & TOE CLEARANCE 6 <br />SCALE: <br />1/4" = 1'-0"OBSTRUCTED REACH 3SCALE: <br />3/8" = 1'-0"PROTRUDING OBJECTS 7 <br />SCALE: <br />1/4" = 1'-0"DOOR MANUEVERABILITY 9 <br />SCALE: <br />1/4" = 1'-0"RECESSED DOOR & GATES MANEUVERING 10 <br />SCALE: <br />1/4" = 1'-0"DOORS & GATES IN SERIES 11 <br />SCALE: <br />3/8" = 1'-0"REDUCED VERTICAL CLEARANCE 12 <br />SCALE: <br />1/4" = 1'-0"RAMPS 16 <br />SCALE: <br />1/2" = 1'-0"DOOR ELEVATION (MANUAL)1 2 <br />SCALE: <br />1" = 1'-0"EXTERIOR POWER DOOR CONTROL LOCATIONS1 4 <br />DATE: <br />DRAWN: <br />REVIEWED: <br />PROJECT NO: <br />SCALE: <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF <br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED <br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, <br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />SHEET TITLE: <br />SHEET NO: <br />SEAL AND STAMP: <br />CONSULTANTS: <br />PROJECT: <br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO - <br />NEW JERSEY - NEW YORK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />515 South Flower Street, Suite 1200 <br />Los Angeles, CA 90071 <br />T 310.553.3252 <br />T 949.724.8958 <br />T 213.929.1400 <br />DRAWINGS ISSUE <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />T 848.200.1200 <br />711 3rd Ave., 6th Floor <br />New York, NY 10017 <br />T 917.512.6688 <br />www.saaia.com <br />T 415.390.6793 <br />NOT FOR CONSTRUCTION <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE <br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE <br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH <br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE <br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY <br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING <br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT <br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY <br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF <br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF <br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO <br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE <br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO <br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT, <br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />575 Market Street, #502 <br />San Francisco, CA 94105 <br />As indicated <br />A-0.6A <br />04/10/24 <br />AW <br />JN/MP <br />634495 <br />BASE BUILDING <br />ACCESSIBILITY <br />X ENGINEERING <br />6 E HUTTON CENTRE <br />DRIVE <br />SANTA ANA, CA 92707 <br />SUITE 650 EXPANSION <br />DATE DESCRIPTION DELTA <br />05/08/24 TENANT REVISION <br />05/20/24 ISSUE FOR PLAN CHECK <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025L,CEN S E ' ARC+,7 <br />E <br />C7S7A <br />7 <br />E O) CA L ,)O RN,A6 E Hutton Center Dr <br />Unit# 625 & 6509/23/2024