1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" )15" MIN..48" MAX.10" MAX.
<br />UNOBSTRUCTED SIDE REACH15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH
<br />(A)
<br />(C)
<br />(B)
<br />(D)
<br />48" MIN.
<br />48" MIN.
<br />48" MIN.48" MIN.27" MAX.X<80"GUARDRAIL OR BARRIER
<br />NOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL
<br />IN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A HAZARD, THE
<br />EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROM
<br />THE DIRECTION OF THE STAIR FLIGHT.
<br />11B-505.5
<br />11B-505.6
<br />11B-504.4.1
<br />11B-505.2
<br />CONTRASTING COLOR STRIPE SHALL BE 2"-4" WIDE, POSITIONED PARALLEL TO AND
<br />NOT MORE THAN 1" AWAY FROM THE NOSE. THE STRIPE SHALL EXTEND THE FULL
<br />WIDTH OF THE STEP AND SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP
<br />RESISTANT AS THE REST OF THE TREADS. PAINTED STRIPES ARE ACCEPTABLE.
<br />GROOVES ARE NOT ACCEPTABLE.
<br />WHERE REQUIRED:
<br />1.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND THE LOWER
<br />TREAD MARKED BY A COLOR STRIPE PROVIDING CLEAR VISUAL CONTRAST.
<br />2.EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS
<br />MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST.
<br />PROVIDE
<br />CONTINUOUS
<br />HANDRAILS ON BOTH
<br />SIDES OF THE STAIRS
<br />FOR THE FULL LENGTH
<br />OF EACH STAIR FLIGHT
<br />HANDRAIL EXTENSIONS MUST BE PROVIDED
<br />AT THE TOP AND BOTTOM OF EACH STAIR FLIGHT AND MUST
<br />RETURN TO A WALL, GUARD, OR THE LANDING SURFACE OR SHALL
<br />BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT
<br />NOTE: INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS
<br />SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS
<br />1 1/2"
<br />MIN.1 1/2"MIN.1" MAX.2"-4"
<br />CONTRASTING COLOR STRIP
<br />11B-504.4.1
<br />11B-505.10
<br />11B-505.10
<br />(B) SECTION/ELEVATION(B-ALT) ALT. SECTION/ELEVATION 34" - 38"
<br />PLUS (1) TREAD
<br />DEPTH MIN12".
<br />12"
<br />MIN.
<br />11" MIN.
<br />UNIFORM
<br />TREAD DEPTH
<br />4"-7"
<br />UNIFORM
<br />RISER HEIGHT
<br />X<27"
<br />12"
<br />MIN
<br />NOTE: IN ALTERATIONS, WHERE THE EXTENSION OF THE
<br />HANDRAIL IN THE DIRECTION OF STAIR FLIGHT WOULD CREATE A
<br />HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90
<br />DEGREES FROM THE DIRECTION OF THE STAIR FLIGHT.
<br />11B-505.10
<br />11B-505.10 11B-505.10
<br />11B-505.7.1
<br />4"-6 1/4" PERIMETER
<br />4"-6 1/4" PERIMETER
<br />(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE)
<br />2 1/4"2 1/4"11B-505.7.2
<br />*EXCEPTIONS
<br />1. THE CLEAR WIDTH SHALL BE PERMITTED TO BE
<br />REDUCED TO 32" MIN. FOR A LENGTH OF 24" MAX.
<br />PROVIDED THAT REDUCED WIDTH SEGMENTS ARE
<br />SEPARATED BY SEGMENTS THAT ARE 48" LONG MIN.
<br />AND 36" WIDE MIN.
<br />2. THE CLEAR WIDTH FOR WALKING SURFACES IN
<br />CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR
<br />MORE SHALL BE 44" MIN.
<br />3. THE CLEAR WIDTH FOR SIDEWALKS AND WALKS
<br />SHALL BE 48" MIN.. WHEN, BECAUSE OF
<br />RIGHT-OF-WAY RESTRICTIONS, NATURAL BARRIERS
<br />OR OTHER EXISTING CONDITIONS, THE ENFORCING
<br />AGENCY DETERMINES THAT COMPLIANCE WITH THE
<br />48" CLEAR SIDEWALK WIDTH WOULD CREATE AN
<br />UNREASONABLE HARDSHIP, THE CLEAR WIDTH MAY
<br />BE REDUCED TO 36".
<br />4. THE CLEAR WIDTH FOR AISLES SHALL BE 36" MIN. IF
<br />SERVING ELEMENTS ON ONLY ONE SIDE, AND 44"
<br />MIN. IF SERVING ELEMENTS ON BOTH SIDES.
<br />5. THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO
<br />ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44"
<br />EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR
<br />SWINGS.
<br />(B) EXCEPTION 1
<br />(A) MINIMUM CLEAR WIDTH, MAX. SLOPE
<br />2.0% MAX.
<br />5.0% MAX.
<br />(TYP
<br />U.O.N.)36" MIN.*36" MIN.*32" MIN.24" MAX.48" MIN. 24" MAX.
<br />11B-403.5.1
<br />(A) FORWARD APPROACH48" MIN.30 MIN.30" MIN.48" MIN.
<br />(B) PARALLEL APPROACH
<br />(1) THE CLEAR FLOOR SPACE (CFS) MUST BE STABLE,
<br />FIRM, AND SLIP RESISTANT.
<br />(2) OPENINGS MUST NOT ALLOW THE PASSAGE OF A
<br />SPHERE MORE THAN 1/2" IN DIAMETER. ELONGATED
<br />OPENINGS MUST BE PERPENDICULAR TO THE
<br />DOMINANT DIRECTION OF TRAVEL.
<br />CHANGES IN LEVEL ARE NOT PERMITTED WITHIN THE
<br />CLEAR FLOOR SPACE. SLOPES WITHIN THE CFS MUST BE
<br />NO GREATER THAN 2%
<br />THE CFS MAY INCLUDE COMPLIANT KNEE AND TOE
<br />CLEARANCE.
<br />ONE FULLY UNOBSTRUCTED SIDE OF THE CFS MUST
<br />ADJOIN AN ACCESSIBLE ROUTE OR ANOTHER CLEAR
<br />FLOOR OR GROUND SPACE
<br />11B-305.5 11B-305.5
<br />11B-302.1
<br />11B-302.3
<br />11B-305.2
<br />11B-305.4
<br />11B-305.6
<br />9" MIN.8" MIN.27" MIN.11" MIN.
<br />25" MAX.30" MIN.(A) KNEE CLEARANCE
<br />ELEVATION
<br />(B) KNEE CLEARANCE
<br />PLAN
<br />17"-25"30" MIN.9"6" MAX.
<br />(A)
<br />ELEVATION
<br />(B)
<br />PLAN
<br />11B-306.3 11B-306.3
<br />11B-306.2 11B-306.2
<br />>10"-24" MAX.34" MAX.46" MAX.34" MAX.48" MAX.10" MAX.
<br />(a) (b)48" MAX.20" MAX.>20"-25" MAX 44" MAX.(a) (b)
<br />OBSTRUCTED HIGH FORWARD REACH
<br />OBSTRUCTED HIGH SIDE REACH
<br />11B-308.2.1 11B-308.3.1
<br />11B-308.2.2
<br />11B-308.3.2X≥80"4" MAX.X>27"12" MAX.27" - 80"
<br />12" MAX.27" MAXX>12"X>12"80" MIN.LIMITS OF PROTRUDING OBJECTS
<br />(A)(B)
<br />POST-MOUNTED PROTRUDING OBJECTS
<br />11B-307.2
<br />11B-307.3
<br />(A) FRONT APPROACH, PULL SIDE
<br />(B) FRONT APPROACH, PUSH SIDE
<br />(C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PUSH SIDE
<br />(E) LATCH APPROACH, PULL SIDE (F) LATCH APPROACH, PUSH SIDE
<br />18"
<br />MIN.60" MIN.48" MIN.ADD 12" IF A CLOSER AND
<br />LATCH ARE PROVIDED
<br />ADD 6" AT EXTERIOR SIDE
<br />OF EXTERIOR DOORS
<br />60" MIN.36" MIN.42" MIN.22" MIN.48" MIN.24" MIN.42" MIN.24" MIN.ADD 4" IF CLOSER AND
<br />LATCH IS PROVIDED
<br />11B-404.2.4.1
<br />11B-404.2.4.1
<br />11B-404.2.4.1 11B-404.2.4.1
<br />11B-404.2.4.1 11B-404.2.4.1
<br />ADD 4" IF CLOSER AND
<br />LATCH IS PROVIDED
<br />(A) RECESSED DOOR, PULL SIDE (B) RECESSED DOOR PUSH SIDE
<br />18"
<br />MIN.48" MIN.ADD 12" IF A
<br />CLOSER AND
<br />LATCH ARE
<br />PROVIDED
<br />ADD 6" AT
<br />EXTERIOR SIDE
<br />OF EXTERIOR
<br />DOORS 60" MIN.X>8"X>8"3'-0"
<br />11B-404.2.4.1 11B-404.2.4.1
<br />11B-404.2.6 11B-404.2.6
<br />11B-404.2.6
<br />11B-307.42.0% MAX2.0% MAX.RAMP DOWN 8.33% MAX.2.0% MAX2.0% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />8.3% MAX.
<br />2.0% MAX.
<br />8.3% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />8.3% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />2.0% MAX.
<br />PROVIDE CONTINUOUS
<br />HANDRAILS
<br />ON BOTH SIDES OF RAMP FOR
<br />THE
<br />FULL LENGTH OF EACH RAMP
<br />RUN
<br />1 1/2"
<br />MIN.1 1/2"MIN.TOP LANDING WITH A
<br />CHANGE
<br />IN DIRECTION SHOWN
<br />PROVIDE EDGE PROTECTION AT
<br />EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP
<br />LANDINGS WHERE A CHANGE IN LEVEL OCCURS.
<br />EXCEPTIONS:
<br />1. WHERE RAMPS ARE NOT REQUIRED TO HAVE
<br />HANDRAILS AND AT CURB RAMP FLAIRS NOT
<br />STEEPER THAN 1:10 HAVE FLARED SIDES.
<br />2.ON THE SIDES OF RAMP LANDINGS SERVING AN
<br />ADJOINING RAMP RUN OR STAIR.
<br />3.WHERE AN ABRUPT CHANGE IN LEVEL OF 1/2"
<br />MAX. OCCURS WITHIN 10" OF THE MINIMUM
<br />LANDING AREA.
<br />2" - 4" HIGH EDGE PROTECTION (CURB OR BARRIER)
<br />SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED
<br />BARRIER ALONG THE LENGTH OF A RAMP TO PREVENT
<br />WHEEL ENTRAPMENT.
<br />HANDRAIL EXTENSIONS
<br />MUST BE PROVIDED AT THE TOP AND BOTTOM
<br />LANDINGS OF EACH RAMP RUN AND MUST
<br />RETURN TO A WALL, GUARD, OR THE LANDING
<br />SURFACE OR SHALL BE CONTINUOUS TO THE
<br />HANDRAIL OF AN ADJACENT RAMP RUN.
<br />NOTE: INSIDE HANDRAILS ON SWITCHBACK OR
<br />DOGLEG RAMPS SHALL BE CONTINUOUS
<br />BETWEEN FLIGHTS OR RUNS
<br />HANDRAILS MAY PROJECT INTO THE
<br />REQUIRED CLEAR WIDTH OF THE
<br />RAMP AT EACH SIDE A MAXIMUM OF
<br />3 1/2" AT THE HANDRAIL HEIGHT
<br />AT LEAST AS WIDE AS THEWIDEST RAMP RUN (TYP.)60" MIN.
<br />BOTTOM LANDING
<br />5'-0" MINIMUM
<br />INTERMEDIATE LANDING
<br />(STRAIGHT)
<br />5'-0" MINIMUM
<br />INTERMEDIATE LANDING
<br />(CHANGE IN DIRECTION)60" MINIMUMINTERMEDIATE LANDING(CHANGE IN DIRECTION)5'-0" MINIMUMTOP LANDINGRAMP RUN
<br />DOWN
<br />RAMP RUNDOWNRAMP RUN
<br />DOWN
<br />5'-0" MINIMUM
<br />TOP LANDING
<br />NOTES:
<br />·THE CLEAR WIDTH OF A RAMP RUN MUST BE 48" MINIMUM.
<br />·WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES ARE PERMITTED
<br />TO OVERLAP THE REQUIRED LANDING AREA. DOORS, IN ANY POSITION, MUST NOT REDUCE THE MINIMUM
<br />DIMENSION OF THE RAMP LANDING TO LESS THAN 42"
<br />·LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER.
<br />BOTTOM LANDING
<br />11B-405
<br />11B-405
<br />11B-505.10.1
<br />11B-505.10.1
<br />11B-1012.4
<br />X>27"
<br />12"
<br />MIN.34" - 38"
<br />12"
<br />MIN.
<br />12"
<br />MIN.30" MAX. RISE FOREACH RAMP RUN(B) HANDRAIL MOUNTING HEIGHT AND EXTENSIONS1 1/4"-2"(C) CIRCULAR HANDRAIL SECTION PROFILE (SCALE 6" = 1'-0" )
<br />4"-6 1/4" PERIMETER
<br />4"-6 1/4" PERIMETER
<br />(D) NON-CIRCULAR HANDRAIL SECTION PROFILES (3" = 1'-0" SCALE)
<br />2 1/4"2 1/4"CURB 2" MIN. - 4" MAX. TO
<br />PREVENT THE PASSAGE OF A 4"
<br />DIAMETER SPHERE
<br />GUIDE RAIL POSITIONED TO PREVENT
<br />THE PASSAGE OF A 4" DIAMETER SPHERE
<br />(D) EDGE PROTECTION - BARRIER
<br />(D) EDGE PROTECTION - CURB 43" MAX> 66"34" - 44"404.2.11 VISION LIGHTS
<br />DOORS, GATES, AND SIDE LIGHTS ADJACENT TO
<br />DOORS OR GATES, CONTAINING ONE OR MORE
<br />GLAZING PANELS THAT PERMIT VIEWING
<br />THROUGH THE PANELS SHALL HAVE THE
<br />BOTTOM OF AT LEAST ONE GLAZED PANEL
<br />LOCATED 43 INCHES (1090 MM) MAXIMUM
<br />ABOVE THE FINISH FLOOR.
<br />EXCEPTION: VISION LIGHTS
<br />WITH THE LOWEST PART
<br />MORE THAN 66 INCHES
<br />(1675 MM) FROM THE
<br />FINISH FLOOR OR GROUND
<br />SHALL NOT BE REQUIRED
<br />TO COMPLY WITH
<br />404.2.11.
<br />404.2.10 DOOR AND GATE SURFACES
<br />SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH
<br />SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE
<br />SURFACES SHALL BE WITHIN 1/16 INCH (1.6 MM) OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED.
<br />EXCEPTIONS:
<br />1. SLIDING DOORS SHALL NOT BE REQUIRED TO COMPLY WITH 404.2.10.
<br />2. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM
<br />FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH (255 MM) BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT.
<br />3. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY
<br />WITH 404.2.10.
<br />4. EXISTING DOORS AND GATES WITHOUT SMOOTH SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED
<br />TO PROVIDE SMOOTH SURFACES COMPLYING WITH 404.2.10 PROVIDED THAT IF ADDED KICK PLATES ARE INSTALLED, CAVITIES CREATED BY SUCH KICK
<br />PLATES ARE CAPPED.
<br />FINISH FLOOR OR GROUND
<br />7" - 8"30" - 44"5" MAX.35" MIN.2" MIN.
<br />VERTICAL ACTUATION BARWHERE PUSH PLATES ARE
<br />PROVIDED THERE SHALL BE
<br />TWO PUSH PLATES
<br />PUSH PLATE 4"
<br />SQUARE OR 4 "
<br />DIAMETER MINIMUM
<br />INT'L SYMBOL OF
<br />ACCESSIBILITY,
<br />TYPICAL.
<br />SCALE:
<br />3/8" = 1'-0"STAIRWAYS 13
<br />SCALE:
<br />1/4" = 1'-0"ACCESSIBLE ROUTE MIN. WIDTH 1
<br />SCALE:
<br />1/4" = 1'-0"REQUIRED CLEAR FLOOR SPACE 5
<br />SCALE:
<br />3/8" = 1'-0"KNEE & TOE CLEARANCE 6
<br />SCALE:
<br />1/4" = 1'-0"OBSTRUCTED REACH 3SCALE:
<br />3/8" = 1'-0"PROTRUDING OBJECTS 7
<br />SCALE:
<br />1/4" = 1'-0"DOOR MANUEVERABILITY 9
<br />SCALE:
<br />1/4" = 1'-0"RECESSED DOOR & GATES MANEUVERING 10
<br />SCALE:
<br />1/4" = 1'-0"DOORS & GATES IN SERIES 11
<br />SCALE:
<br />3/8" = 1'-0"REDUCED VERTICAL CLEARANCE 12
<br />SCALE:
<br />1/4" = 1'-0"RAMPS 16
<br />SCALE:
<br />1/2" = 1'-0"DOOR ELEVATION (MANUAL)1 2
<br />SCALE:
<br />1" = 1'-0"EXTERIOR POWER DOOR CONTROL LOCATIONS1 4
<br />DATE:
<br />DRAWN:
<br />REVIEWED:
<br />PROJECT NO:
<br />SCALE:
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF
<br />FURNISHED BY SAA INTERIORS ARE AND SHALL REMAIN IT'S PROPERTY. THEY ARE TO BE USED
<br />ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION,
<br />DISPLAY, SALE, OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN
<br />CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />SHEET TITLE:
<br />SHEET NO:
<br />SEAL AND STAMP:
<br />CONSULTANTS:
<br />PROJECT:
<br />CULVER CITY - IRVINE - LOS ANGELES - SAN FRANCISCO -
<br />NEW JERSEY - NEW YORK
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />515 South Flower Street, Suite 1200
<br />Los Angeles, CA 90071
<br />T 310.553.3252
<br />T 949.724.8958
<br />T 213.929.1400
<br />DRAWINGS ISSUE
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />T 848.200.1200
<br />711 3rd Ave., 6th Floor
<br />New York, NY 10017
<br />T 917.512.6688
<br />www.saaia.com
<br />T 415.390.6793
<br />NOT FOR CONSTRUCTION
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE
<br />AT THE TIME OF AND RELATING TO COVID-19 CONTAIN RECOMMENDATIONS FROM THE
<br />CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH
<br />ORGANIZATION (WHO), SUCH RECOMMENDATIONS ARE ONLY VALID AS OF THE DATE THE
<br />DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY
<br />THEIR RECOMMENDATIONS AT ANY TIME PER THEIR DISCRETION. IN USING
<br />RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT
<br />ACKNOWLEDGES THAT IT WAS BASED ON THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY
<br />AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF
<br />THESE DRAWINGS AND MATERIALS BY OTHERS. SAA’S SERVICES ARE INTENDED TO ONLY BE OF
<br />ASSISTANCE AND GUIDANCE FOR OUR CLIENT’S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO
<br />REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR COMPLETENESS OF THE
<br />DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO
<br />INFORMATION DOES NOT CONSTITUTE ENDORSEMENT BY THE U.S. GOVERNMENT,
<br />DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />575 Market Street, #502
<br />San Francisco, CA 94105
<br />As indicated
<br />A-0.6A
<br />04/10/24
<br />AW
<br />JN/MP
<br />634495
<br />BASE BUILDING
<br />ACCESSIBILITY
<br />X ENGINEERING
<br />6 E HUTTON CENTRE
<br />DRIVE
<br />SANTA ANA, CA 92707
<br />SUITE 650 EXPANSION
<br />DATE DESCRIPTION DELTA
<br />05/08/24 TENANT REVISION
<br />05/20/24 ISSUE FOR PLAN CHECK
<br />NELSON
<br />ALGAZE
<br />No. C-21090
<br />REN. 03/31/2025L,CEN S E ' ARC+,7
<br />E
<br />C7S7A
<br />7
<br />E O) CA L ,)O RN,A6 E Hutton Center Dr
<br />Unit# 625 & 6509/23/2024
|