Expedited Permit Process for PV Systems 5 Notes for Standard String System Electrical DiagramContractor Name,Address and Phone:____________________________________________________________________Notes for One-Line Standard ElectricalDiagram for Single-Phase PV SystemsSite Name: __________________________Site Address: ________________________System AC Size: ______________________SIZEFSCM NODWG NOREVSCALENTSDate:SHEETDrawn By:Checked By:MAX POWER-POINT CURRENT (IMP)MAX POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)MAX SERIES FUSE (OCPD)MAXIMUM POWER (PMAX)MAX VOLTAGE (TYP 600VDC)VOC TEMP COEFF (mV/oC or %/oC )IF COEFF SUPPLIED, CIRCLE UNITS AVVAAWVMODULE MAKEMODULE MODELPV MODULE RATINGS @ STC (Guide Section 5)MAX DC VOLT RATINGMAX POWER @ 40oCNOMINAL AC VOLTAGEMAX AC CURRENTMAX OCPD RATINGVWVAAINVERTER MAKEINVERTER MODELINVERTER RATINGS (Guide Section 4)1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THEREQUIREMENT? YES NO N/A3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAXCURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTEROCPD AMPERE RATING. (See Guide Section 9)5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTALSUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)?YES NONOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEANEXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHESTMONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT ATLEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLERFUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLERFUSE.NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D):OCPD = OVERCURRENT PROTECTION DEVICENATIONAL ELECTRICAL CODE® REFERENCESSHOWN AS (NEC XXX.XX)NOTES FOR ALL DRAWINGS:SIGNS–SEE GUIDE SECTION 7SIGN FOR DC DISCONNECTSIGN FOR INVERTER OCPD ANDAC DISCONNECT (IF USED)RATED MPP CURRENTRATED MPP VOLTAGEMAX SYSTEM VOLTAGEMAX CIRCUIT CURRENTAVVAPHOTOVOLTAIC POWER SOURCEWARNING: ELECTRICAL SHOCKHAZARD–LINE AND LOAD MAY BEENERGIZED IN OPEN POSITIONAC OUTPUT CURRENTNOMINAL AC VOLTAGE AVSOLAR PV SYSTEMAC POINT OF CONNECTIONTHIS PANEL FED BY MULTIPLESOURCES (UTILITY AND SOLAR)849 E McFadden Ave-101119004 & 201826064/29/2024